Message DescriptionsProperty Management System - Communication Interface
• Recovery Start Report
• Recovery End Report
• Data Link Release Request
• Data Link Release Confirmation
• Extension Number Request
• Nop Test
Data Link Failure Either system may recognize a loss of communication by one or more of the following events:
• Lack of system traffic for a 60 second interval: the Nop Test message from the PMS and the Nop Test Answer message (either Normal or Recover) from the NEAX insure that at least one message should be received less than every 60 seconds.
• Detection of hardware problems within the physical data. Note that the NEAX will put EIA pin number 6 (Data Set Ready) into the off state, indicating data set not ready, when the data link has been effectively turned off in the NEAX, either for maintenance or because of repeated, excessive errors.
• Excessive protocol errors (NAK’ed transmission, ENQ’s with no ACK/NAK response).
• Other conditions, such as unavailability of buffers or queuing capability, which result in an implied status change message which cannot be communicated to the other system.
• Release of the data link requested and confirmed.
A data link failure will necessitate a database room exchange recovery procedure only if any implied status change cannot be communicated to the other system and cannot be queued for later transmission. If no messages have been lost, and can instead be retransmitted, no database recovery is necessary.