Specifications
Section 5: Specifications
Item |
|
|
| Description |
|
| |||
Electrical Supply | Standard U.S. Models: 110 - 125 V ac | |||
| Japan J Models: 100 V AC, 60 Hz only | |||
| Korea KK Models: 220 V AC, 60 Hz only | |||
|
|
|
| |
Power Consumption | 400 W |
|
| |
|
|
| ||
Dimensions | • | Height: 119 mm (4.69 in.) without TRAY | ||
| • | Width: 238 mm (12.93 in.) | ||
| • | Length: 295 mm (11.6 in.) | ||
|
| |||
Slide size | 35 mm, 50 x 50 mm (2 x 2 in.) | |||
|
|
| ||
Slide change time | 1 second |
| ||
|
|
| ||
Lamp | • | EXR 82 V, 300 W, 35 hours average life | ||
(in LO position) | • | EXW 82 V, 300 W, 15 hours average lamp life | ||
| ||||
| • | FHS 82 V, 300 W, 70 hours average life | ||
| • | EXY 82 V, 300 W, 200 hours average life | ||
|
| |||
Lumen Output | • 900 minimum with EXR lamp | |||
| • | Lowest corner to center ratio is 55% minimum | ||
| • | Test method: | ||
|
| – | Ektagraphic | |
|
| – 102 mm, F/2.8 LENS aperture (24 x 36 mm), compatible | ||
|
|
| with European specification DIN 19027 | |
|
|
|
|
|
Operating temperature | • | 4.5 | C (40 | F), 15% humidity in low |
| • | 49 | C (120 | F), 15% humidity in high |
| • | 21 - 27 C (70 - 80 F), 20 - 60% humidity optimum | ||
|
| |||
Cooling | Fan speed is 2780 or 3000 RPMs, 1360 BTUs per hour to cool | |||
| projector |
| ||
|
|
|
|
|
Approvals | UL |
|
|
|
|
| |||
Environmental storage | Complies with storage test specifications (TS 172) | |||
|
| |||
Environmental operation | Complies with climactic test specifications (TS 218) | |||
|
| |||
Safety | • 3 GROUNDED POWER CORDS, detachable | |||
| • | Heat sensitive interrupt fuses | ||
| • | 109 C power to motor (lamp fuse) | ||
| • 171 C MOTOR | |||
|
| |||
Dielectric strength | Apply 1200 V AC, 60 Hz for 1 second; maximum leakage | |||
| current is 2.5 mA. | |||
|
| |||
Automatic Timer | Operates between the following times: | |||
| • | Fast = 3 1 second | ||
| • | Slow = 22 | 6 seconds | |
|
|
| ||
Elevation | 14 | maximum front elevation assembly. | ||
|
|
|
|
|
41 |