SERVICE MANUAL
Malfunction |
| Check |
|
| |
TIMER does not operate | 1. Check the VARIABLE RESISTOR for | |
|
| correct operation and install a new part if |
|
| necessary. |
| 2. | Move the TIMER BUTTON forward and |
|
| backward; use a DVM to check for changes |
|
| in W. |
| 3. | Energize the projector and move the TIMER |
|
| to “S”. |
|
| • Check the voltages on CR3, Q3, and |
|
| Q4, see the voltage table. |
|
|
|
DARK SHUTTER SWITCH does not operate | 1. | Energize the projector and release the |
|
| DARK SHUTTER to allow projection. |
| 2. | Check for continuity between PINS 4 and 5 |
|
| on the SPECIAL APPLICATIONS PLUG. |
| 3. | Press the “FORWARD” or “REVERSE” |
|
| BUTTONS to close the DARK SHUTTER. |
| 4. | In the closed position, the DVM should |
|
| measure 0 W. |
| 5. | If this procedure does not correct the |
|
| malfunction, install a new DARK SHUTTER |
|
| SWITCH. |
|
|
|
ZERO POSITION SWITCH does not operate | 1. | Deenergize the projector. |
| 2. | Check for continuity between PINS 1 and 3 |
|
| on the SPECIAL APPLICATIONS PLUG. |
| 3. | Install a SLIDE TRAY. |
| 4. | Rotate the SLIDE TRAY to engage the |
|
| ZERO POSITION SWITCH, the DVM |
|
| should measure 0 W. |
| 5. | If the W measurement is not correct, see |
|
| the adjustment for the ZERO POSITION |
|
| SWITCH. Install a new ZERO POSITION |
|
| SWITCH if necessary. |
|
| |
After the FOCUS MOTOR energizes and | 1. Remove R3 and install a new 68K W 1/4 W | |
moves, the FOCUS MOTOR oscillates. |
| RESISTOR (part 220040). |
| 2. | If there is still a malfunction, install a new |
|
| PHOTOCELL. |
|
|
|
50 | 30APR96 – |