Kodak A-61555 manual If you are using iThresholding, reduce the Contrast value

Page 105

Problem

Possible Solution

Calibration has failed

Make sure that:

 

• you are using the proper calibration target and it is oriented correctly for

 

the type of calibration you are performing. The Image calibration target

 

and Ultrasonics calibration target are different.

 

• the imaging guides are clean.

 

• the transport is clear of obstructions.

 

• the sensors are clean.

 

• the calibration target you are using is clean.

 

If unsatisfactory image quality persists, call Service.

 

 

Documents are jamming

Make sure that:

 

• the guidelines for document preparation have been followed (e.g.,

 

staples, paper clips are removed; lead edges are aligned, etc.)

 

• the output tray and side guides are adjusted for the length and width of

 

the documents being scanned.

 

• all jammed documents have been removed from the transport area.

 

• documents meet specifications for size and weight.

 

• the sensors are clean.

 

• the separation roller, feed module, and pre-separation pad are clean

 

and properly installed.

 

• the transport rollers are clean.

 

• the background strips are properly installed.

 

• you have checked the feed module tires, separation roller tires and pre-

 

separation pad for signs of wear and replaced as needed.

 

 

Long documents are not feeding or are

Make sure that:

jamming

• the input elevator extender is pulled out to provide support for long

 

documents.

 

• the output tray is adjusted for the length of the documents being

 

scanned.

 

• the output tray is installed properly.

 

• document extenders are installed correctly.

 

 

Roller marks appear on the documents

Clean the feed module tires, separation roller tires and transport rollers.

after scanning

 

 

 

Vertical streaks appear on the image

Make sure that:

 

• imaging guides are clean.

 

• the scanner was thoroughly cleaned before the last image calibration.

 

• when you calibrate the scanner that you are using a good, clean

 

calibration target. Use the calibration target provided with your scanner.

 

If you are using iThresholding, reduce the Contrast value.

 

 

The Enhanced Printer is not printing as

If you are having problems printing on scanned documents:

desired

• verify that the ink cartridge is not empty.

 

• be sure the ink cartridge is properly installed.

 

• be sure the ink cartridge is located in the correct position for printing.

 

• make sure that the printer carrier is properly seated in its slot.

 

• verify that all printer connectors are securely fastened and that the

 

ribbon cable is securely attached.

 

• verify that the printer has been enabled through the host and that the

 

expected print string has been specified.

Image too small or has a black border • Clean the imaging guides. See Chapter 5, Maintenance.

Clean the scanner. See Chapter 5, Maintenance.

If using iThresholding, reduce the Contrast value.

Check for scratches on the black (or white) background strips. Replace if necessary.

A-61555 April 2009

6-13

Image 105
Contents Page Contents Enhanced Printer/Patch Readers Appendix B Introduction New features Scanner features Supporting documentation System requirementsPhone numbers United States and Canada Contacting Service and SupportMsds Safety informationEnvironmental information EMC statementsAcoustic emission Power systemConnection NetzanschlußScanner components Front view Getting StartedPage Page Internal components Rear view Turning the scanner on Using the ScannerApril Turning the scanner off Starting and stopping scanning Document preparationMaterials Page Selecting your feeding Adjusting the input elevatorPosition Locking the side guidesPage Adjusting the output tray Adjusting the side guidesOutput tray options Page Adjusting the angle of the output tray Adjusting the end stopPage Exit deflector Page Adjusting the short document tray Adjusting the height of the scanner Automatic feeding Feeding documents using multi-feed detectionContinuous feeding Manual feeding Feeding documents that require special handling Using the operator control panel touchscreen Settings screen Page Selecting the tone Selecting a language Page Page Image Calibration Udds Calibration For millimeters Printer unitsFragile Feed mode Message window Idle screenOperator Log Image Address informationInformation Accessing scannerCount only mode Performing a Print test Lowering the elevator Page Disabling the Printer Select Print Offset. The following screen will be displayedPage Performing a self test Scanning Using function keys when scanningChanging image address levels Manually pausing and resuming the scanner Automatically pausing and resuming the scannerResuming from Power Saver mode Power Saver mode Viewing messagesEnhanced Printer overview Enhanced Printer and Patch ReadersFont size Printer specificationsChanging the front horizontal print position Changing print positionsHorizontal print position Changing the rearPage Page Replacing the ink cartridge Page Replacing the front blotter strips Page Replacing the rear blotter strips Patch function overview Patch ReadersPatch types Toggle Patch Patch code placementMaintenance Procedure Start Middle Start of new Day Shift Cleaning frequency chart Cleaning tools and materialsOrdering parts Supplies, consumables and accessoriesCleaning procedures Cleaning the rollers Cleaning the separation roller tires Cleaning the feed module tires Close the printer access cover April Edges of the transport Guides basic cleaning Cleaning the imagingUpper imaging guide Cleaning the imaging guides thorough cleaningLower imaging guide Running a transport Cleaning sheetFinal cleaning steps Replacement procedures Align these areas IMPORTANTDo not overstretch the tire it may tear Locking tab Replacing the separation roller or separation roller tires Separation pad Replacing the preReplacing the imaging GuidesAccessing Operator Log TroubleshootingAccessing the Operator Log from the Scan Validation tool Page Page ID# Message listingEnhanced Printer and Patch Readers for more Image Processing Guide for valid values Informational message. The pod was closed April Numerical message Contacting Service Problem Possible Solution Problem solvingIf you are using iThresholding, reduce the Contrast value Ultralightweight Paper Feed Module Background Accessory Kodak Manual FeederResolution Printer Accessory Appendix B Specifications