Messages | ID# | Operator Message |
Input elevator too full, feed module | 297 | • There is too much paper in the input elevator and it is holding |
missing or broken |
| the feed module up. The maximum input elevator capacity is |
|
| 500 sheets. Remove some documents from the input elevator. |
|
| • The feed module is not installed properly. See Chapter 5, |
|
| Maintenance, for correct installation procedures. |
|
| • If the problem persists, call Service. |
|
|
|
Invalid job setup | 4 | The image processing values sent by the host are invalid or in |
|
| conflict with one another. |
|
| • Check the job settings for illegal combinations. Refer to the |
|
| Image Processing Guide for valid values. |
|
|
|
Jam in transport | 30 | A document is lodged in the transport. |
|
| • Remove the documents that have been scanned from the |
|
| output tray. |
|
| • Open the pod. |
|
| • Remove any jammed documents from inside the transport. |
|
| • Close the pod. |
|
| NOTE: The following procedure is a general guideline. Your |
|
| procedure may be different depending on how your |
|
| application is set up. |
|
| • Verify the last document that was scanned correctly. |
|
| • Place any documents that were not scanned at the top of the |
|
| batch. |
|
| • Place the documents in the input elevator and begin scanning. |
|
| One or more documents that passed through the transport were |
|
| not scanned. |
|
| • Refeed all documents for which images were not obtained. |
|
|
|
Lamps not ready for calibration | 107 | Calibration was attempted before the lamps were warmed up. |
|
| • Wait until the lamps have completely warmed (90 seconds) |
|
| and try the calibration again. |
|
|
|
Lamps not ready for scanning | 359, 19 | Scanning was attempted before the lamps were warmed up. |
|
| • Wait for the message Lamps ready for scanning to be |
|
| displayed and scan again. |
|
|
|
Lamps ready for calibration | 108 | Informational message. The lamps are warmed and a calibration |
|
| can be performed now, if needed. This does not indicate that a |
|
| calibrate is needed. |
|
|
|
Lamps ready for scanning | 280 | Informational message. The lamps are warmed and scanning |
|
| can be initiated. |
Lamps timed out | 355 | Informational message. The lamps were turned off due to |
|
| inactivity. |
|
|
|
No paper input elevator | 46 | The scanner was started with an empty input elevator or the |
|
| portion of the document that is covering the paper present |
|
| sensor is too dark (the back side of the bottom page). |
|
| • Place the documents you want to scan in the input elevator |
|
| and try again. |
|
| • Offset the document until the paper present sensor detects it. |
|
|
|
|