Major Components

Figure 2 Liebert GXT3, rear view

Liebert GXT3, 5,000 & 6000VA

Terminal Block

 

Communication

 

 

 

 

REPO

C19 Output Power

 

 

 

Liebert IntelliSlot® Port

 

 

USB Port

 

 

Receptacles

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Output Circuit

Breakers

C13 Output

Receptacles

Removable Power

 

 

 

 

 

 

 

 

 

Distribution Box

 

 

 

factory-attached in

Maintenance

bottom-left corner

Bypass Breaker

 

External Battery

Connector

IT Power System

Access Cover

Output

Circuit

Breakers

Output

Knockouts

Input Circuit

Circuit

for Hardwired

Breaker

Breaker

Power Input

 

 

 

Liebert GXT3, 10,000VA

Reserved

Terminal Block

Communication

REPO

Maintenance

Bypass Breaker

Input Circuit

Breaker

Output Circuit

Breaker

C13 Output

Receptacles

Removable Power Distribution Box factory-attached in bottom-left corner

USB Port

C19 Output

Output Circuit Breakers

Receptacles

 

 

 

External Battery

Connector

Liebert

IntelliSlot

Port

Output

Knockouts

IT Power System

Circuit

Access Cover

Breakers

for Hardwired

 

 

Power Input

 

Liebert® GXT3

8

Image 14
Contents Liebert GXT3 230V,5000-10,000VA Page Table of Contents Specifications MaintenanceTroubleshooting Figures Page Important Safety Instructions Information for the Protection of the Environment Glossary of Symbols Introduction Inverter Rectifier/Power Factor Correction PFC CircuitBattery Charger System DescriptionDynamic Bypass BatteryDC-to-DC Converter Main Frame and Electronics Major ComponentsC19 Output Power Liebert GXT3, 5,000 & 6000VA Terminal Block CommunicationInternal Battery Packs Removable Power Distribution BoxWHAT’S Included Tower UPS Installation Install the Main CabinetInstallation and Configuration Connectors Spacers Support BasesOperation and Display Panel Rotated Clockwise 90 Degrees Rack-Mount UPS InstallationInstalling the Adjustable Rack-Mount Kit-Sold Separately QuantityDepth UPS or battery813mm Retaining latchExternal Battery Cabinet Installation Slide into the bracket assemblies more easilyExternal battery cabinets connected to 10,000VA Liebert GXT3 Connect Input/Output Power Extract These Captive screws Maintenance Bypass BreakerBranch circuit breaker ratings Electrical specificationsDistribution Box Electrical Connections Unit Rating Maximum Breaker RatingOutput Input What You Will Need Configuration Program FeaturesConfiguration Program Standby/Manual Bypass Button ON/Alarm Silence/Manual Battery Test ButtonControls and Indicators Load Level Indicators 4 Green, 1 Amber Battery Level Indicators 5 GreenUPS Status Indicator Icon Color Description UPS Status IndicatorsUPS status indicators Operation Startup Checklist for the Liebert GXT3Initial Startup and Electrical Checks Maintenance Bypass Manual Battery TestDisconnecting Input Power from the Liebert GXT3 Put the Liebert GXT3 in Manual BypassRemove Screws IT Power System ConfigurationConnectors Terminal Block Communication Any Mode ShutdownCommunication Interface Port CommunicationLow Battery Battery Mode ShutdownOn Battery Liebert IntelliSlot Communication CardsLiebert MultiLink Remote Emergency Power OffRepo switch connection diagram Battery Replacement Procedures Replacing the Internal Battery PackMaintenance 6000VA model shown5000 & 6000 VA models Battery ChargingPrecautions Checking UPS Status Checking UPS FunctionsIndicators UPS SymptomsTroubleshooting Indicator Diagnosis/Audible alarmTroubleshooting table Audible AlarmAudible alarm description Condition AlarmYour UPS has received a signal or command from Specifications UPS specificationsOperating temperature parameters Power distribution specificationsExternal battery cabinet specifications See TableBattery run time, minutes, all models Auto-Learning Battery Run Times Specifications Liebert GXT3 Page Twor k Ne tIs t Care