Operation

8.8IT Power System Configuration

1.Remove screws on the IT Power System Access Cover as shown in Figure 15.

2.Disconnect the connectors as shown in figure.

3.Install IT Power System Access Cover and screws.

Figure 15 Remove cover from IT Power System Connectors compartment

Remove Screws

IT Power System

Connectors

 

25

Liebert® GXT3

Image 31
Contents Liebert GXT3 230V,5000-10,000VA Page Table of Contents Troubleshooting MaintenanceSpecifications Figures Page Important Safety Instructions Information for the Protection of the Environment Glossary of Symbols Introduction System Description Rectifier/Power Factor Correction PFC CircuitBattery Charger InverterDC-to-DC Converter BatteryDynamic Bypass Major Components Main Frame and ElectronicsLiebert GXT3, 5,000 & 6000VA Terminal Block Communication C19 Output PowerRemovable Power Distribution Box Internal Battery PacksWHAT’S Included Connectors Spacers Support Bases Install the Main CabinetInstallation and Configuration Tower UPS InstallationQuantity Rack-Mount UPS InstallationInstalling the Adjustable Rack-Mount Kit-Sold Separately Operation and Display Panel Rotated Clockwise 90 DegreesRetaining latch UPS or battery813mm DepthSlide into the bracket assemblies more easily External Battery Cabinet InstallationExternal battery cabinets connected to 10,000VA Liebert GXT3 Extract These Captive screws Maintenance Bypass Breaker Connect Input/Output PowerUnit Rating Maximum Breaker Rating Electrical specificationsDistribution Box Electrical Connections Branch circuit breaker ratingsOutput Input Configuration Program Configuration Program FeaturesWhat You Will Need Controls and Indicators ON/Alarm Silence/Manual Battery Test ButtonStandby/Manual Bypass Button Battery Level Indicators 5 Green Load Level Indicators 4 Green, 1 AmberUPS status indicators UPS Status IndicatorsUPS Status Indicator Icon Color Description Initial Startup and Electrical Checks Startup Checklist for the Liebert GXT3Operation Put the Liebert GXT3 in Manual Bypass Manual Battery TestDisconnecting Input Power from the Liebert GXT3 Maintenance BypassConnectors IT Power System ConfigurationRemove Screws Communication Any Mode ShutdownCommunication Interface Port Terminal Block CommunicationLiebert IntelliSlot Communication Cards Battery Mode ShutdownOn Battery Low BatteryRepo switch connection diagram Remote Emergency Power OffLiebert MultiLink 6000VA model shown Replacing the Internal Battery PackMaintenance Battery Replacement ProceduresPrecautions Battery Charging5000 & 6000 VA models Checking UPS Functions Checking UPS StatusIndicator Diagnosis/Audible alarm UPS SymptomsTroubleshooting IndicatorsCondition Alarm Audible AlarmAudible alarm description Troubleshooting tableYour UPS has received a signal or command from UPS specifications SpecificationsPower distribution specifications Operating temperature parametersSee Table External battery cabinet specificationsBattery run time, minutes, all models Auto-Learning Battery Run Times Specifications Liebert GXT3 Page Care Ne tIs t Twor k