3
Table
PMC Slots Available Power
Note:
A maximum load current of 6 amps (worst case) results in a voltage drop of approximately 100 mV to the PMC 5 volt power supply inputs. To ensure proper module operation, adjust the CompactPCI power supply to accommodate any voltage drop or power supply ripple that may occur when operating the carrier card.
P M C / P C I I N T E R F A C E
PMC Module Installation
3.3 Volts: | 5 Volts: |
| 3 3 and 5 Volts Combined: |
. . . . . . . . . . | . . . . . . . . . . |
| . . . . . . . . . . . . . . . . |
| |||
8.5 amps | 6 amps |
|
|
|
|
|
|
2To prevent ESD damage to the CC1000dm carrier card and the PMC modules, wear a grounding wriststrap and use a grounded work surface while handling the card.
3Set up the PMC module and install it on the CC1000dm carrier card as specified in the module’s hardware manual.
Monarch Functionality Each slot (PMC1 and PMC2) on the CC1000dm carrier card can be configured to func- tion as either a Monarch or
Device Mapping
Table
IDSEL Mapping for PCI
Devices
Once the Monarch PMC module has completed initialization of the CC1000dm local bus, the PCI agents located on that bus are available for access. There are up to two PCI devices installed on the PLX PCI 6254 (HB6) secondary bus and two PCI IDSEL lines allocated to each PMC slot. Table
PCI Address Line: Local PCI Device IDSEL Connection:
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
AD22 | PMC 1 |
|
|
AD21 | PMC 1 Alternate Device |
|
|
AD20 | PMC 2 |
|
|
AD19 | PMC 2 Alternate Device |
|
|
AD18 | PLX PCI 6254 (HB6) PCI Bridge |
|
|