Page 12

Even with the output off the load is still connected to the power supply output stage. Do not apply external voltages in excess of 50V to the power supply terminals or damage may result.

The output is protected from reverse voltages by a diode; the continuous reverse current must not exceed 3 Amps, although transients can be much higher.

Ventilation

The power supply is very efficient but nevertheless can generate significant heat at full power. The supply relies on convection cooling only and it is therefore important that ventilation is never restricted if performance and safety are to be maintained. If the supply is mounted in a restricted space, eg. a 19 inch rack, then adequate ventilation must be ensured by using, for example, a fan tray.

Maintenance

The Manufacturers or their agents overseas will provide repair for any unit developing a fault. Where owner wish to undertake their own maintenance work, this should only be done by skilled personnel in conjunction with the service manual which may be purchased directly from the Manufacturers or their agents overseas.

Fuse

The correct fuse type for both AC supply ranges is:

10 Amp 250V HBC time-lag, 5 x 20mm.

Make sure that only fuses of the required rated current and specified type are used for replacement. The use of makeshift fuses and the short-circuiting of fuse-holders is prohibited.

To replace the fuse, first disconnect the instrument from the AC supply. Remove the 6 cover securing screws and lift off the cover. Replace the fuse with one of the correct type and refit the cover.

Note that the main function of the fuse is to make the instrument safe and limit damage in the event of failure of one of the switching devices. If a fuse fails it is therefore very likely that the replacement will also blow, because the supply has developed a fault; in such circumstances the instrument will need to be returned to the manufacturer for service.

Cleaning

If the PSU requires cleaning use a cloth that is only lightly dampened with water or a mild detergent. Polish the display window with a soft dry cloth.

WARNING! TO AVOID ELECTRIC SHOCK, OR DAMAGE TO THE PSU, NEVER ALLOW WATER TO GET INSIDE THE CASE. TO AVOID DAMAGE TO THE CASE OR DISPLAY WINDOW NEVER CLEAN WITH SOLVENTS.

11

Image 12
Contents XPF Series Dual Output 35V 10A Powerflex DC Power Supply XPFPart Number Contact InformationTable of Contents Specification Output SpecificationsMeter Specifications Safety Emissions ImmunityInstallation Mains Operating VoltageMains Lead MountingConnections Operation Connection to the Load Remote SensingSeries or Parallel connection with other units ProtectionMaintenance CleaningVentilation FuseAccess to Calibration Adjustments CalibrationEquipment Required Set Power Limit Voltage CalibrationCurrent Calibration OVP CalibrationSécurité AVERTISSEMENT! CET Instrument Doit Etre Relie a LA TerreTension d’utilisation secteur Câble secteurMontage Connexions OpérationConnexion à la charge TélédétectionConnexion en série ou en parallèle avec d’autres appareils Fusible NettoyageSicherheit WARNUNG! Dieses Gerät Muss Geerdet WerdenNetzbetriebsspannung NetzkabelAufstellung/Montage Anschlüsse BetriebLeistungsgrenze VerbraucheranschlussIstwert-Fernerfassung Reihen- und Parallelschaltung mit anderen Geräten ÜberspannungsschutzWartung SicherungReinigung Sicurezza Attenzione Questo Strumento Deve Essere Collegato a TerraInstallazione Tensione d’esercizioCavo d’Alimentazione MontaggioCollegamento FunzionamentoLimite di potenza Allacciamento del caricoRilevamento a distanza Collegamento in serie/parallelo con altre unitàProtezione VentilazioneManutenzione FusibilePulizia Seguridad ADVERTENCIA! Este Instrumento Debe Conectarse a TierraInstalación Voltaje de trabajo de alimentaciónCable de red MontajeConexiones FuncionamientoConexión a la carga Detector remotoConexión en serie o en paralelo a otras unidades Mantenimiento ProtecciónVentilación LimpiezaWarranty Information How do you get service?What does this warranty not cover? ProductReturn Material Authorization Policy Xantrex Technology Inc