Fujitsu RX200 S5 manual Trusted Platform Module TPM, Installing the TPM module

Page 59

11 Trusted Platform Module (TPM)

VCAUTION!

Follow the safety instructions in the chapter “Safety instructions” on page 13.

The Trusted Platform Module (TPM) is installed on the system board between riser cards #1 and #2 (see photo below). It is used for safe storage of key infor- mation (e.g. drive encryption using Windows BitLocker Drive Encryption).

ÊOpen the server as described in chapter “Preparation” on page 19.

1

2

3

Figure 36: Installing the TPM module

ÊInsert the plastic post supplied (3) into the square opening between riser cards #1 and #2 on the system board. Make sure that the post engages.

ÊInsert the TPM (2) in the corresponding socket on the system board and secure it using the screw supplied (1).

ÊClose the server, connect all power plugs to the power outlets, and switch on the server as described in chapter “Completion” on page 61.

RX200 S5

Options Guide

59

Image 59
Contents Primergy RX200 S5 Server Certified documentation according to DIN EN ISO Comments… Suggestions… Corrections…Contents Contents Documentation overview PrefaceConcept and target groups Further sources of information Documentation overview PrefaceExpansions and conversions TPM Expansions and conversions PrefaceNotational conventions Page Procedure Page Safety instructions Before starting up Installation and operationOptions Guide Batteries Never remove parts of the CD/DVD drive casing Working with CDs/DVDs and CD/DVD drivesLaser information ESD label Modules with electrostatic-sensitive componentsPulling out/removing the server PreparationRemoving the fan cover Removing the housing coverOpening the server Opening the server PreparationOpening the server Removing the air cowl Preparation Removing the air cowlProcessors Installing a second processorInserting the processor Installing a second processorProcessors Installing the heat sinkReplacing the processor Replacing the processorReplacing the processor Replacing the processor Replacing the heat sink Page Main memory Equipping rules Independent Channel ModeMirrored Channel Mode Equipping rulesMain memory Performance Channel ModeSpare Channel Mode Extending/replacing the main memory Removing installed memory modulesExtending/replacing the main memory Inserting a memory module Inserting memory modulesPage Accessible drive Installing a Sata DVD drive Installing a Sata DVD driveInstalling a Sata DVD drive Page HDD modules Removing the DVD drive or dummy module Removing an existing DVD drive or dummy moduleDemounting the DVD drive cage Removing the DVD drive cageRemoving the existing backplane 6x HDD Installing the backplane 8x HDDInstalling the HDD drive cage Installing the drive cage for 8x HDDInserting the HDD modules HDD #6 HDD #7Expansion cards and iBBU Installing an expansion card in riser cardsRemoving the riser card holders Installing an expansion card in riser cardsInstalling an expansion card Riser card holder #2 with riser card Riser card holder equipped with a controller Reinstalling the riser card holdersExpansion cards and iBBU Installing a modular RAID controllerInstalling a RAID controller Installing the riser card holderInstalling an iBBU Installing an iBBUInstalling an iBBU Installing the iBBU IBBU Routing the cable Connecting the cable to the modular RAID 5 controller Position of the uSSD on the system board USB solid state disk uSSDPage Trusted Platform Module TPM Installing the TPM modulePage Fitting the air cowl CompletionFitting the air cowl Dimm CPU #1Completion Fan #3/#4 Fan #1/#2Fan #11/#12 Fit the fan cover see Removing the fan cover on Closing the serverPage Description From CablingCabling overview Cable diagrams Cabling Cable diagramsCabling for up to 6 HDD modules Cabling for up to 8 HDD modules Index