Prompt | AS/400 Parameter | Field | Subfield | Value | 5494 Value | Notes |
|
|
|
|
|
|
|
Local | ADPTADR | H1 | 5 | - | - | Values specified in the AS/400 |
adapter |
|
|
|
|
| line description (CRTLINTRN |
address |
|
|
|
|
| command) and for the 5494 |
|
|
|
|
|
| Remote Controller Unit must |
|
|
|
|
|
| match. |
|
|
|
|
|
|
|
LAN | ADPTADR | 15 | - | - | - | Values specified for the AS/400 |
remote |
|
|
|
|
| CRTCTLAPPC command and |
adapter |
|
|
|
|
| for the 5494 Remote Control |
address |
|
|
|
|
| Unit must match. |
|
|
|
|
|
|
|
Local | LCLLOCNAME | H1 | 1 | - | - | Values specified for the AS/400 |
location |
|
|
|
|
| CRTCTLRWS command and |
name |
|
|
|
|
| for the 5494 Remote Control |
|
|
|
|
|
| Unit must match. This will |
|
|
|
|
|
| probably match LCLLOCNAME |
|
|
|
|
|
| in the network attributes. This |
|
|
|
|
|
| value will probably match the |
|
|
|
|
|
| LCLLOCNAME in the network |
|
|
|
|
|
| attributes. |
|
|
|
|
|
|
|
Link type | LINKTYPE | AA | - | *LAN | 4 | 5494 configuration values must |
|
|
|
|
|
| match the values specified for |
|
|
|
|
|
| the LINKTYPE parameter on |
|
|
|
|
|
| the CRTCTLAPPC command. |
|
|
|
|
|
| For APPC controllers that |
|
|
|
|
|
| specify LINKTYPE(*SDLC), the |
|
|
|
|
|
| value specified in the 5494 |
|
|
|
|
|
| configuration must be |
|
|
|
|
|
| compatible with the physical |
|
|
|
|
|
| interface (INTERFACE |
|
|
|
|
|
| parameter) specified on the |
|
|
|
|
|
| CRTLINSDLC command. |
|
|
|
|
|
| Select 4 for the network |
|
|
|
|
|
| connections. |
|
|
|
|
|
|
|
Remote | RMTCPNAME | 13 | - | - | - | Values specified for the AS/400 |
control |
|
|
|
|
| CRTCTLAPPC command and |
point name |
|
|
|
|
| for the 5494 Remote Control |
|
|
|
|
|
| Unit must match. |
|
|
|
|
|
|
|
Remote | RMTNETID | 11 | 3 | - | - | Values specified for the AS/400 |
network |
|
|
|
|
| CRTCTLAPPC and |
identifier |
|
|
|
|
| CRTCTLRWS commands and |
|
|
|
|
|
| for the 5494 Remote Control |
|
|
|
|
|
| Unit must match. This will |
|
|
|
|
|
| probably match LCLNETID in |
|
|
|
|
|
| the network attributes and |
|
|
|
|
|
| H1:2. |
|
|
|
|
|
|
|
Remote | RMTLOCNAME | 12 | - | - | - | Values specified for the AS/400 |
location |
|
|
|
|
| CRTCTLRWS command and |
name |
|
|
|
|
| for the 5494 Remote Control |
|
|
|
|
|
| Unit must match. |
|
|
|
|
|
|
|
Example: Connecting an AS/400 to a 5494 controller connected by frame relay
Configuration parameters must be coordinated when you connect an AS/400 system to a 5494 controller.
Chapter 7. Communicating with remote workstation controllers 47