IBM manual Matching AS/400 parameters for Fbss finance controllers, AS/400 AS/400 Prompt

Page 70

 

AS/400

 

 

AS/400 Prompt

Parameter

4700 Macro

4700 Parameter

 

 

 

 

Maximum

MAXFRAME

COMLINK

CNL

frame size

 

 

Value specified for the 4700 CNL parameter must be

 

 

 

 

 

 

coordinated with the value specified for the AS/400 MAXFRAME

 

 

 

parameter on the CRTCTLFNC command. Because the

 

 

 

MAXFRAME parameter includes transmission and request

 

 

 

header lengths, MAXFRAME should be 9 bytes longer than the

 

 

 

4700 MWL parameter.

 

 

 

 

 

 

 

MWL

 

 

 

Value specified for the 4700 MWL parameter must be

 

 

 

coordinated with the value specified for the AS/400 MAXFRAME

 

 

 

parameter on the CRTCTLFNC command. Because the

 

 

 

MAXFRAME parameter includes transmission and request

 

 

 

header lengths, MAXFRAME should be 9 bytes longer than the

 

 

 

4700 MWL parameter.

 

 

 

If the AS/400 maximum length of request unit (MAXLENRU

 

 

 

parameter) specified for device descriptions attached to the 4700

 

 

 

controller is larger than the MAXFRAME parameter specified for

 

 

 

the controller description, the 4700 should also specify

 

 

 

OPTIONS=(SEGMENT).

 

 

 

 

NRZI data

NRZI

COMLINK

ACB

encoding

 

 

For SDLC finance communications, if the line does not use NRZI

 

 

 

 

 

 

data encoding (NRZI(*NO) on the CRTLINSDLC command),

 

 

 

include the DCE value on the ACB parameter (ACB = DCE).

 

 

 

 

Station address

STNADR

X25CKT

CUA

 

 

 

The values specified for the AS/400 STNADR parameter on the

 

 

 

CRTCTLFNC command must match the physical address (CUA)

 

 

 

parameter specified for the 4700.

 

 

 

 

Matching AS/400 parameters for FBSS finance controllers

You must coordinate several parameter values that are specified for the AS/400 system and IBM Financial Branch System Services (FBSS) finance controllers in the controller configuration. The following table shows those AS/400 configuration parameters that must match values on the SDLC, Token-Ring, or X.25DLC configuration displays for FBSS controllers.

AS/400 prompts are listed in alphabetical order by parameter name; the AS/400 commands on which the parameters are specified are included in the rightmost column of the table.

For more information about configuring FBSS controllers, see the IBM Financial Branch System Services Installation Planning and Administration Guide, SC19-5173.

For more information about configuring the 4700 controllers, see Volume 6 of the 4700 Finance Communication System Controller Programming Library, GC31-2068.

To configure the AS/400 to a FBSS finance controller:

vSee “Example: Connecting AS/400 to a finance network” on page 67 for an example of connecting an AS/400 to a 4701 finance controller.

vUse the following table to connect an AS/400 to a 4701 finance controller.

64Version 5

Image 70
Contents ERserver Page ERserver Page Contents Troubleshooting communications problems Part 1. Getting started with AS/400 communications Version Print this topic Version Creating a network server description Configuring AS/400 for communicationsCreating a network interface description Creating a line descriptionVersion Optimizing communications performance Adjusting WAN protocols for optimum AS/400 performanceAdjusting the WAN line speed for optimum AS/400 performance Improving wide area network performanceWAN line speed considerations for IOPs Adjusting LAN lines for optimum communications performance Adjusting LANs for optimum communications performanceImproving local area network performance LAN line speed considerations for IOPs Improving data path performanceAddcmne SBSDlibname/sbsname DEVdevname* MODEmodename Example Communications subsystem configuration Set up the communication entriesCommunications performance considerations for batch jobs Example Interactive subsystem configurationMixing interactive and batch jobs on a WAN line Performance considerations for AnyNet communications Setting up the AnyNet environmentAnyNet communications for the AS/400 system Subsystems QusrwrkVersion User written Appc applications Communications applicationsDistributed data management DDM Version Communications applications Version Communicating with host systems Matching AS/400 parameters for a host systemSSAP/DSAP/remote-adapter-address Name Rmtnetid Vtamlst Netid Maxframe Group MaxdataRmtcpname Vtamlst Sscpname Ssap SapaddrLocadr Locaddr Mode Modeent LogmodeLcllocname Dfhtct Netname Locpwd Dfhtct BindpwdModd Modeent Logmode Examples Connecting AS/400 to a host systemAS/400 Host Definition AS/400 Prompt Cosd Modeent COSCommunicating with host systems Version Communicating with host systems Version Configuring the host controller description Configuring dependent LU requester DlurConfiguring the device descriptions Version Adptadr Communicating with a remote AS/400 systemAS/400 Remote AS/400 AS/400 Prompt AdrinsertAS/400 Remote AS/400 AS/400 Prompt Parameter Cnnpwd X25DCECnnnbr Netadr Dsap SsapRmtcpname Lclcpname InlcnnLinkpcl Rmtnetid LclnetidConnecting one AS/400 to another AS/400 system Version Communicating with a remote AS/400 system Version Communicating with remote workstation controllers Matching AS/400 parameters for 5494 controllersRmtcpname AS/400 5494 Prompt AS/400 Parameter Field Subfield ValueLAN RmtnetidAS/400 5494 Prompt AS/400 Parameter Field Subfield Linktype LANMatching AS/400 parameters for a 5494 connected by Ethernet AS/400 5494 Prompt Parameter Field Subfield Value Version LAN Adptadr Matching AS/400 parameters for a 5494 connected by Sdlc AS/400 Prompt Parameter Field Subfield AS/400 ValueField Subfield AS/400 Value Communicating with remote workstation controllers Matching AS/400 parameters for a 5494 connected by Example Connecting AS/400 to a 5494 controller connected by LinktypeIBM 5494 Remote Control Unit Planning Guide, GA27-3936 Ellc DftpktsizeLinkpcl Qllc NetlvlAS/400 5494 Prompt Field Subfield ValueCommunicating with remote workstation controllers Matching AS/400 parameters for a 3174 controller 3174 AS/400 Configuration PromptMatching AS/400 parameters for 3x74 controller Questions3174 AS/400 Configuration Prompt Parameter Questions NRZ or Nrzi Encoding Switched Short-Hold ModeMatching AS/400 parameters for a 3274 controller Control Unit Address3274 AS/400 Example Connecting an AS/400 to a 3174 control unitPrompt Parameter Number Matching AS/400 parameters for finance controllers Matching AS/400 parameters for 470x finance controllersAS/400 AS/400 Prompt Parameter Macro AS/400 AS/400 Prompt Matching AS/400 parameters for Fbss finance controllersMacro Parameter Line mode Switched lineService access point for PC PC addressMatches the Fbss Identification number Service access point for Host/37xx/4700Identification block and Identification number Data Link ControlExample Connecting AS/400 to a finance network Matching AS/400 parameters for retail controllersMatching AS/400 parameters for 3651 retail controllers AS/400 Definition AS/400 Prompt Parameter StatementAS/400 Definition AS/400 Prompt AS/400 Parameter Sdlclin Bit Bit ValueMatching AS/400 parameters for 3684 retail controllers 3684 AS/400 Definition Prompt3684 AS/400 Definition Prompt Parameter CNN*MP SNBU*NO Matching AS/400 parameters for 4680/4690 Line parameterAS/400 Parameter Linecon Bit Bit Value SNBU*YES MODEMRATE*FULLAS/400 Prompt AS/400 Parameter Line Parameter Exchid parameter specified on the AS/400 Crtctlrtl commandMatching AS/400 parameters for 4680/4690 Link parameter CNNLocal node Hex Wire constant RTS?Matching AS/400 parameters for 4684 retail controllers Remote node HexExamples Connecting AS/400 to a 4690 retail controller Version Communicating with remote workstation controllers Version Troubleshooting communications problems Displaying message queues to solve communication problemsJob logs and communication problems QsysarbSolving communication problems using communications trace QpasvrpSystem service tools and communication problems Trace option settingSolving communication problems using the system problem log Trace fullUsing error messages to aid in error recovery Solving communication problems using status informationConsiderations for system tuning during error recovery Solving communication problems using reason codesReason Codes for Rejected Program Start Requests Reason Code Reason DescriptionReason Code Reason Description Networking concepts Advanced Peer-to-Peer NetworkingAdvanced program-to-program communications Dependent LU requester supportHPR architecture option sets High-performance routingInternetwork packet exchange support What is Systems Network Architecture What is TCP/IPATM on AS/400 Common networking standardsLocal area network standards Distributed data interface networkWireless network Token-ring networksBinary synchronous communications Wide area network standardsAsynchronous communications Frame relay networksSynchronous data link control network Integrated services digital networkIsdn data link control network Network Version
Related manuals
Manual 489 pages 47.95 Kb Manual 516 pages 58.6 Kb

AS/400 specifications

The IBM AS/400, now known as the IBM iSeries, is a midrange computer system that has been a cornerstone of enterprise computing since its introduction in 1988. Designed to provide a robust platform for business applications, the AS/400 is celebrated for its reliability, scalability, and integrated database capabilities.

One of the key features of the AS/400 is its Integrated Operating Environment, which blends hardware and software resources seamlessly. This integration allows businesses to execute diverse workloads, ranging from traditional applications to modern web-based services, all on a single platform. The operating system, OS/400 (now IBM i), offers a rich set of APIs and tools for developers, simplifying application development and management.

Another standout characteristic of the AS/400 is its built-in database, DB2 for i. This powerful relational database management system allows for efficient data handling and provides advanced features such as support for SQL, XML, and JSON, making it easier for businesses to manage their data and integrate it with other systems. The database's tight integration with the operating system enables high performance and security.

In terms of scalability, the AS/400 can accommodate small businesses as well as large enterprises, with the ability to support hundreds of users simultaneously. Its architecture allows for easy upgrades in hardware, meaning that organizations can scale their systems without replacing the entire infrastructure.

Security is another critical attribute of the AS/400. With a sophisticated security model, it offers built-in user authentication, access control, encryption, and auditing capabilities to protect data and applications from unauthorized access.

The AS/400 also supports multiple programming languages, including RPG, COBOL, Java, and PHP, giving organizations the flexibility to choose the development tools that best fit their needs. This diversity helps maintain legacy applications while also developing new ones that leverage modern technologies.

Moreover, the platform supports both traditional green-screen interfaces and modern graphical user interfaces, allowing organizations to transition smoothly into contemporary user experience paradigms.

Overall, the IBM AS/400 stands out as a resilient, flexible, and secure computing platform that enables organizations to effectively manage their business operations, streamline processes, and adapt to changing market demands. Its unique combination of integrated features and capabilities ensures that it remains relevant in today's fast-paced technology landscape.