IBM Example Connecting an AS/400 to a 3174 control unit, 3274 AS/400, Prompt Parameter Number

Page 67

 

 

3274

 

AS/400

AS/400

Sequence

 

Prompt

Parameter

Number

Notes

 

 

 

 

Connection

CNNNBR

411

3274 DTE Address

number

 

 

For X.25 SVCs, the connection number specified on the

 

 

 

 

 

 

CRTCTLRWS command and in sequence number 411 must

 

 

 

match.

 

 

 

 

Exchange

EXCHID

215

Physical Unit Identification

identifier

 

 

For switched connections, the 5-digit hexadecimal value specified

 

 

 

 

 

 

for sequence number 215 must match the last 5 digits of the

 

 

 

exchange identifier specified on the CRTCTLRWS command.

 

 

 

 

X.25 link

LINKPCL

403

Logical Link Control

protocol

 

 

For X.25 connections, values specified must match. Specify

 

 

 

 

 

 

LINKPCL(*QLLC) on the CRTCTLRWS command; specify 1

 

 

 

(QLLC) for sequence number 403.

 

 

 

 

Link type

LINKTYPE

331

BSC/SDLC/X.25 Protocol

 

 

 

Values specified on the CRTCTLRWS command and in

 

 

 

sequence number 331 must match as follows:

 

 

 

v If LINKTYPE(*SDLC), 331 = 1

 

 

 

v If LINKTYPE(*X25), 331 = 2

Local network

NETADR

410

Host DTE Address (HNAD)

address

 

 

For X.25 SVCs, the network address specified on the

 

 

 

 

 

 

CRTLINX25 command and in sequence number 410 must match.

 

 

 

 

Modem data

MODEMRATE

318

Full- or Half-Speed Transmission

rate select

 

 

The values specified for the MODEMRATE parameter on the

 

 

 

 

 

 

CRTLINSDLC and CRTLINX25 commands must match sequence

 

 

 

number 318 as follows:

 

 

 

v If MODEMRATE(*FULL), 318 = 0

 

 

 

v If MODEMRATE(*HALF), 318 = 1

NRZI data

NRZI

313

NRZ or NRZI Encoding

encoding

 

 

For SDLC lines only, the values specified must match as follows:

 

 

 

 

 

 

v If NRZI(*NO), 313 = 0

 

 

 

v If NRZI(*YES), 313 = 1

Short-hold

SHM

362

X.21 Switched Options

mode

 

 

If SHM(*YES) is specified on the CRTCTLRWS command, digit 7

 

 

 

 

 

 

or 8 of question 362 must be set to 1. (For example, xxxxxx10

 

 

 

indicates that the DCE is supported for direct calls.)

 

 

 

 

Station address

STNADR

302

Control Unit Address

 

 

 

Value specified for item 302 must match that specified on the

 

 

 

CRTCTLRWS command.

 

 

 

 

Example: Connecting an AS/400 to a 3174 control unit

Configuration parameters must be coordinated when you connect an AS/400 system to a 3174 controller.

Chapter 7. Communicating with remote workstation controllers 61

Image 67
Contents ERserver Page ERserver Page Contents Troubleshooting communications problems Part 1. Getting started with AS/400 communications Version Print this topic Version Creating a line description Configuring AS/400 for communicationsCreating a network interface description Creating a network server descriptionVersion Improving wide area network performance Adjusting WAN protocols for optimum AS/400 performanceAdjusting the WAN line speed for optimum AS/400 performance Optimizing communications performanceWAN line speed considerations for IOPs Adjusting LAN lines for optimum communications performance Adjusting LANs for optimum communications performanceImproving local area network performance Improving data path performance LAN line speed considerations for IOPsAddcmne SBSDlibname/sbsname DEVdevname* MODEmodename Set up the communication entries Example Communications subsystem configurationCommunications performance considerations for batch jobs Example Interactive subsystem configurationMixing interactive and batch jobs on a WAN line Performance considerations for AnyNet communications Setting up the AnyNet environmentAnyNet communications for the AS/400 system Qusrwrk SubsystemsVersion User written Appc applications Communications applicationsDistributed data management DDM Version Communications applications Version Matching AS/400 parameters for a host system Communicating with host systemsSSAP/DSAP/remote-adapter-address Name Ssap Sapaddr Maxframe Group MaxdataRmtcpname Vtamlst Sscpname Rmtnetid Vtamlst NetidLocpwd Dfhtct Bindpwd Mode Modeent LogmodeLcllocname Dfhtct Netname Locadr LocaddrCosd Modeent COS Examples Connecting AS/400 to a host systemAS/400 Host Definition AS/400 Prompt Modd Modeent LogmodeCommunicating with host systems Version Communicating with host systems Version Configuring the host controller description Configuring dependent LU requester DlurConfiguring the device descriptions Version Adrinsert Communicating with a remote AS/400 systemAS/400 Remote AS/400 AS/400 Prompt AdptadrAS/400 Remote AS/400 AS/400 Prompt Parameter Dsap Ssap X25DCECnnnbr Netadr CnnpwdRmtnetid Lclnetid InlcnnLinkpcl Rmtcpname LclcpnameConnecting one AS/400 to another AS/400 system Version Communicating with a remote AS/400 system Version Matching AS/400 parameters for 5494 controllers Communicating with remote workstation controllersRmtnetid AS/400 5494 Prompt AS/400 Parameter Field Subfield ValueLAN RmtcpnameLinktype LAN AS/400 5494 Prompt AS/400 Parameter Field SubfieldMatching AS/400 parameters for a 5494 connected by Ethernet AS/400 5494 Prompt Parameter Field Subfield Value Version LAN Adptadr Matching AS/400 parameters for a 5494 connected by Sdlc Prompt Parameter Field Subfield AS/400 Value AS/400Field Subfield AS/400 Value Communicating with remote workstation controllers Matching AS/400 parameters for a 5494 connected by Linktype Example Connecting AS/400 to a 5494 controller connected byIBM 5494 Remote Control Unit Planning Guide, GA27-3936 Netlvl DftpktsizeLinkpcl Qllc EllcField Subfield Value AS/400 5494 PromptCommunicating with remote workstation controllers Questions 3174 AS/400 Configuration Prompt Matching AS/400 parameters for 3x74 controller Matching AS/400 parameters for a 3174 controller3174 AS/400 Configuration Prompt Parameter Questions Control Unit Address Switched Short-Hold ModeMatching AS/400 parameters for a 3274 controller NRZ or Nrzi Encoding3274 AS/400 Example Connecting an AS/400 to a 3174 control unitPrompt Parameter Number Matching AS/400 parameters for 470x finance controllers Matching AS/400 parameters for finance controllersAS/400 AS/400 Prompt Parameter Macro AS/400 AS/400 Prompt Matching AS/400 parameters for Fbss finance controllersMacro Parameter PC address Switched lineService access point for PC Line modeData Link Control Service access point for Host/37xx/4700Identification block and Identification number Matches the Fbss Identification numberMatching AS/400 parameters for retail controllers Example Connecting AS/400 to a finance networkAS/400 Definition AS/400 Prompt Parameter Statement Matching AS/400 parameters for 3651 retail controllersAS/400 Parameter Sdlclin Bit Bit Value AS/400 Definition AS/400 Prompt3684 AS/400 Definition Prompt Matching AS/400 parameters for 3684 retail controllers3684 AS/400 Definition Prompt Parameter SNBU*YES MODEMRATE*FULL Matching AS/400 parameters for 4680/4690 Line parameterAS/400 Parameter Linecon Bit Bit Value CNN*MP SNBU*NOCNN Exchid parameter specified on the AS/400 Crtctlrtl commandMatching AS/400 parameters for 4680/4690 Link parameter AS/400 Prompt AS/400 Parameter Line ParameterRemote node Hex Wire constant RTS?Matching AS/400 parameters for 4684 retail controllers Local node HexExamples Connecting AS/400 to a 4690 retail controller Version Communicating with remote workstation controllers Version Displaying message queues to solve communication problems Troubleshooting communications problemsQsysarb Job logs and communication problemsQpasvrp Solving communication problems using communications traceTrace option setting System service tools and communication problemsTrace full Solving communication problems using the system problem logSolving communication problems using reason codes Solving communication problems using status informationConsiderations for system tuning during error recovery Using error messages to aid in error recoveryReason Code Reason Description Reason Codes for Rejected Program Start RequestsReason Code Reason Description Advanced Peer-to-Peer Networking Networking conceptsDependent LU requester support Advanced program-to-program communicationsHPR architecture option sets High-performance routingInternetwork packet exchange support What is TCP/IP What is Systems Network ArchitectureDistributed data interface network Common networking standardsLocal area network standards ATM on AS/400Token-ring networks Wireless networkFrame relay networks Wide area network standardsAsynchronous communications Binary synchronous communicationsSynchronous data link control network Integrated services digital networkIsdn data link control network Network Version