| 3274 |
|
AS/400 | AS/400 | Sequence |
|
Prompt | Parameter | Number | Notes |
|
|
|
|
Connection | CNNNBR | 411 | 3274 DTE Address |
number |
|
| For X.25 SVCs, the connection number specified on the |
|
|
| |
|
|
| CRTCTLRWS command and in sequence number 411 must |
|
|
| match. |
|
|
|
|
Exchange | EXCHID | 215 | Physical Unit Identification |
identifier |
|
| For switched connections, the |
|
|
| |
|
|
| for sequence number 215 must match the last 5 digits of the |
|
|
| exchange identifier specified on the CRTCTLRWS command. |
|
|
|
|
X.25 link | LINKPCL | 403 | Logical Link Control |
protocol |
|
| For X.25 connections, values specified must match. Specify |
|
|
| |
|
|
| LINKPCL(*QLLC) on the CRTCTLRWS command; specify 1 |
|
|
| (QLLC) for sequence number 403. |
|
|
|
|
Link type | LINKTYPE | 331 | BSC/SDLC/X.25 Protocol |
|
|
| Values specified on the CRTCTLRWS command and in |
|
|
| sequence number 331 must match as follows: |
|
|
| v If LINKTYPE(*SDLC), 331 = 1 |
|
|
| v If LINKTYPE(*X25), 331 = 2 |
Local network | NETADR | 410 | Host DTE Address (HNAD) |
address |
|
| For X.25 SVCs, the network address specified on the |
|
|
| |
|
|
| CRTLINX25 command and in sequence number 410 must match. |
|
|
|
|
Modem data | MODEMRATE | 318 | Full- or |
rate select |
|
| The values specified for the MODEMRATE parameter on the |
|
|
| |
|
|
| CRTLINSDLC and CRTLINX25 commands must match sequence |
|
|
| number 318 as follows: |
|
|
| v If MODEMRATE(*FULL), 318 = 0 |
|
|
| v If MODEMRATE(*HALF), 318 = 1 |
NRZI data | NRZI | 313 | NRZ or NRZI Encoding |
encoding |
|
| For SDLC lines only, the values specified must match as follows: |
|
|
| |
|
|
| v If NRZI(*NO), 313 = 0 |
|
|
| v If NRZI(*YES), 313 = 1 |
SHM | 362 | X.21 Switched Options | |
mode |
|
| If SHM(*YES) is specified on the CRTCTLRWS command, digit 7 |
|
|
| |
|
|
| or 8 of question 362 must be set to 1. (For example, xxxxxx10 |
|
|
| indicates that the DCE is supported for direct calls.) |
|
|
|
|
Station address | STNADR | 302 | Control Unit Address |
|
|
| Value specified for item 302 must match that specified on the |
|
|
| CRTCTLRWS command. |
|
|
|
|
Example: Connecting an AS/400 to a 3174 control unit
Configuration parameters must be coordinated when you connect an AS/400 system to a 3174 controller.