Cisco Systems IE20004TSB, IE20004TSL, IE200016TCB manual General Guidelines

Page 36

Chapter 2 Switch Installation

Preparing for Installation

This equipment is considered Group 1, Class A industrial equipment, according to IEC/CISPR Publication 11. Without appropriate precautions, there may be potential difficulties ensuring electromagnetic compatibility in other environments due to conducted as well as radiated disturbance.

This equipment is supplied as open-type equipment. It must be mounted within an enclosure that is suitably designed for those specific environmental conditions that will be present and appropriately designed to prevent personal injury resulting from accessibility to live parts. The enclosure must have suitable flame-retardant properties to prevent or minimize the spread of flame, complying with a flame-spread rating of 5VA, V2, V1, V0 (or equivalent) if nonmetallic. The interior of the enclosure must be accessible only by the use of a tool. Subsequent sections of this publication might contain additional information regarding specific enclosure-type ratings that are required to comply with certain product safety certifications.

General Guidelines

Before installation, observe these general guidelines:

Caution Proper ESD protection is required whenever you handle Cisco equipment. Installation and maintenance personnel should be properly grounded by using ground straps to eliminate the risk of ESD damage to the switch.

Do not touch connectors or pins on component boards. Do not touch circuit components inside the switch. When not in use, store the equipment in appropriate static-safe packaging.

If you are responsible for the application of safety-related programmable electronic systems (PES), you need to be aware of the safety requirements in the application of the system and be trained in using the system.

This product is grounded through the DIN rail to chassis ground. Use zinc-plated yellow-chromate steel DIN rail to assure proper grounding. The use of other DIN rail materials (such as aluminum, plastic, and so on) that can corrode, oxidize, or are poor conductors can result in improper or intermittent grounding. Secure the DIN rail to the mounting surface approximately every 7.8 in. (200 mm), and use end-anchors appropriately.

When determining where to place the switch, observe these guidelines:

Before installing the switch, first verify that the switch is operational by powering it on and observing boot fast. Follow the procedures in the “Verifying Switch Operation” section on page 2-47.

For 10/100 ports and 10/100/1000 ports, the cable length from a switch to an attached device cannot exceed 328 feet (100 meters).

For 100BASE-FX fiber-optic ports, the cable length from a switch to an attached device cannot exceed 6562 ft (2 km).

Operating environment is within the ranges listed in Appendix A, “Technical Specifications.”

Clearance to front and rear panels meets these conditions:

Front-panel LEDs can be easily read.

Access to ports is sufficient for unrestricted cabling.

Front-panel direct current (DC) power connectors and the alarm connector are within reach of the connection to the DC power source.

Cisco IE 2000 Switch Hardware Installation Guide

2-6

OL-25818-04

 

 

Image 36
Contents Cisco IE 2000 Switch Hardware Installation Guide Americas HeadquartersPage N T E N T S Installation Guidelines Connecting to a Dual-Purpose Port Verifying Switch Operation IP Settings Audience PurposeConventions Related Publications Product Overview Switch Models Model Description Software ImageModel Description Software Image Model Description Software Image Front Panel Cisco IE-2000-4TS-L Front Panel ViewCisco IE-2000-8TC-L Front Panel Cisco IE-2000-16TC-L Front Panel View Cisco IE-2000-16PTC-G-E Switch Front Panel View 10/100BASE-T Downlink Ports10/100BASE-T Uplink Ports 10/100/1000BASE-T Uplink Ports100 Mb/s SFP Module Uplink Slots 100/1000 Mb/s SFP Module Uplink SlotsDual-Purpose Gigabit Ethernet Uplink Ports SFP ModulesType of SFP Module Model Power Connectors GLC-LH-SMAlarm Connector PoE Power ConnectorManagement Ports USB Mini-Type B PortLEDs on the Cisco IE 2000 Switch LEDsExpress Setup LED System LEDUSB-Mini Console LED Alarm LEDs Power Status LEDsPort Status LEDs Dual-Purpose Port LEDs Dual-Purpose Port LEDsFlash Memory Card PoE Status LEDColor PoE Status 10 Flash Memory Card Slot Rear Panel Management OptionsNetwork Configurations Switch Installation Preparing for Installation140F 60C Statement Hazardous Area Installation Warnings 1080 Installation Guidelines North American Hazardous Location ApprovalEnvironment and Enclosure Guidelines General Guidelines Installing or Removing the Flash Memory Card Optional Verifying Package ContentsInstalling the Flash Memory Card in the Switch Connecting to a Console Port RJ-45 Console Port USB Mini-Type B Console PortConnecting the Console Cable RJ-45 Console PortUSB Mini-Type B Console Port Removing the USB Mini-Type B Console Port CoverChoose Start Control Panel Systems Connecting to Power Supported Power SuppliesTools and Equipment Grounding the Switch DimensionsAttachable? UsageSlide the ground screw through the terminal Ground cable Connecting the Power Converter to an AC Power Source Preparing the AC Power ConnectionConnecting the AC Power Source to the Power Converter Connecting AC PowerConnecting the Power Converter to a DC Power Source Wiring the DC Power Source Statement 12 Stripping the Power Connection Wire Label14 Inserting Wires in the Power Connector 15 Torquing the Power Connector Captive Screws Attaching the Power Connectors to the Switch 16 Completed DC Power Connections on the Power Connectors17 Attaching the Power Connectors to the Switch 18 Connecting the Power Connectors to the Switch Connecting Power to the Switch PoE DC-Input Optional 332021 Applying Power to the Power Converter Running Boot FastPowering On the Switch Installing the Switch Verifying Boot FastDisconnecting Power Installing the Switch on a DIN Rail DIN Rail SwitchRemoving the Switch from a DIN Rail Connecting Alarm Circuits Wiring the Protective Ground and DC Power for Alarm CircuitsWiring the External Alarms Label Connection21 Removing the Alarm Connector 332225 Attaching the Alarm Connector to the Switch Connecting Destination Ports 25 Connecting the Alarm Connector to the SwitchConnecting to 10/100 and 10/100/1000 Ports 26 Connecting to an Ethernet Port Installing and Removing SFP Modules Installing SFP Modules into SFP Module Slots28 Installing an SFP Module into an SFP Module Slot Removing SFP Modules from SFP Module SlotsConnecting to SFP Modules LC connector Connecting to a Dual-Purpose Port Verifying Switch Operation Where to Go NextSwitch Installation Where to Go Next Diagnosing Problems Switch Boot FastSwitch LEDs Switch ConnectionsBad or Damaged Cable Ethernet and Fiber-Optic CablesInterface Settings 10/100 and 10/100/1000 Port ConnectionsSFP Module Ping End DeviceSwitch Performance Speed, Duplex, and AutonegotiationAutonegotiation and Network Interface Cards Cabling DistanceResetting the Switch How to Recover PasswordsFinding the Switch Serial Number Serial Number Location for the Cisco IE-2000 SwitchesTechnical Specifications Operating Temperature SpecificationsTechnical Specifications Power RequirementsEnvironmental Ranges Table A-2 Cisco IE 2000 Series Technical Specifications Physical Dimensions Table A-2 Cisco IE 2000 Series Technical Specifications Alarm Ratings Alarm Ratings SpecificationHazardous Locations Standards Hazardous Locations StandardsConnector Specifications 10/100 PortsSFP Module Connectors Dual-Purpose PortsConsole Port Alarm Port Figure B-5 USB Type A-to-USB 5-Pin Mini-Type B CableCables and Adapters SFP Module CablesCore Modal Wavelength Commercial SFPsMHz/km1 Cable Distance Extended temperature SFPs Bandwidth Type of SFP Module Nanometers Fiber TypeCable Pinouts TP3Console Port Adapter Pinouts Figure B-9Switch Console RJ-45-to-DB-25 Port DTE Adapter Device DSR DTR CTS RTSOL-25818-04 Accessing the CLI Through the Console Port Removing the USB Mini-Type B Console Port CoverFigure C-1 Removing the USB Mini-Type B Console Port Cover Figure C-2 Connecting the Console Cable Figure C-3 Connecting the USB-Mini Console Cable Installing the Cisco Microsoft Windows USB Device Driver Installing the Cisco Microsoft Windows XP USB DriverInstalling the Cisco Microsoft Windows 2000 USB Driver Uninstalling the Cisco Microsoft Windows USB Driver Using the Add or Remove Programs UtilityEntering the Initial Configuration Information IP SettingsCompleting the Setup Program Enter an enable password, and press Return These choices appear