Cisco Systems IE200016TCB, IE20004TSB manual Grounding the Switch, Dimensions, Attachable?, Usage

Page 44

Chapter 2 Switch Installation

Connecting to Power

 

Table 2-1

Supported Power Supplies

 

 

 

 

 

 

 

 

5.9 in H x 2.1 in. W x

5.9 in. H x 2.1 in. W x

5.8 in. H x 2 in. W x

5.8 in. H x 2 in. W x

Dimensions

4.9 in. D

 

4.9 in. D

4.4 in. D

4.4 in. D

 

 

 

 

 

 

Attachable?

Non-attachable

 

Non-attachable

Attachable unit

Attachable unit

 

 

 

 

 

 

Designed for PoE1

Designed for PoE

Powers the switch.

Powers the switch.

 

modules, can be used to

modules, can be used to

Cannot be used to

Cannot be used to

 

power the switch.

power the switch.

power PoE modules,

power PoE modules,

Usage

 

 

 

which require 48V DC.

which require 48V DC.

 

 

 

 

 

 

1.The models that support PoE provide up to four ports of either PoE (15.4 W per port; IEEE 802.3af) or PoE+ (30 W per port; IEEE 802.3at), depending on the power source used. See Power Requirements, page A-2.

Installing the Power Converter on a DIN Rail, Wall, or Rack Adapter

You install the power converter on a DIN rail, wall, or rack as you would a switch module.

Warning This equipment is supplied as “open type” equipment. It must be mounted within an enclosure that is suitably designed for those specific environmental conditions that will be present and appropriately designed to prevent personal injury resulting from accessibility to live parts. The interior of the enclosure must be accessible only by the use of a tool.

The enclosure must meet IP 54 or NEMA type 4 minimum enclosure rating standards. Statement 1063

Caution To prevent the switch assemble from overheating, there must be a minimum of 3 inches (76.19 mm) between any other device and the top, bottom, or sides of the switch assembly.

Grounding the Switch

Make sure to follow any grounding requirements at your site.

Warning This equipment must be grounded. Never defeat the ground conductor or operate the equipment in the absence of a suitably installed ground conductor. Contact the appropriate electrical inspection authority or an electrician if you are uncertain that suitable grounding is available. Statement 1024

Warning This equipment is intended to be grounded to comply with emission and immunity requirements. Ensure that the switch functional ground lug is connected to earth ground during normal use. Statement 1064

Caution To make sure that the equipment is reliably connected to earth ground, follow the grounding procedure instructions, and use a UL-listed ring terminal lug suitable for number 10-to-12 AWG wire, such as Hollingsworth part number R3456B or equivalent)

 

Cisco IE 2000 Switch Hardware Installation Guide

2-14

OL-25818-04

Image 44
Contents Cisco IE 2000 Switch Hardware Installation Guide Americas HeadquartersPage N T E N T S Installation Guidelines Connecting to a Dual-Purpose Port Verifying Switch Operation IP Settings Conventions AudiencePurpose Related Publications Product Overview Switch Models Model Description Software ImageModel Description Software Image Model Description Software Image Front Panel Cisco IE-2000-4TS-L Front Panel ViewCisco IE-2000-8TC-L Front Panel Cisco IE-2000-16TC-L Front Panel View Cisco IE-2000-16PTC-G-E Switch Front Panel View 10/100BASE-T Downlink Ports10/100BASE-T Uplink Ports 10/100/1000BASE-T Uplink Ports100 Mb/s SFP Module Uplink Slots 100/1000 Mb/s SFP Module Uplink SlotsType of SFP Module Model Dual-Purpose Gigabit Ethernet Uplink PortsSFP Modules Power Connectors GLC-LH-SMAlarm Connector PoE Power ConnectorManagement Ports USB Mini-Type B PortLEDs on the Cisco IE 2000 Switch LEDsUSB-Mini Console LED Express Setup LEDSystem LED Alarm LEDs Power Status LEDsPort Status LEDs Dual-Purpose Port LEDs Dual-Purpose Port LEDsColor PoE Status Flash Memory CardPoE Status LED 10 Flash Memory Card Slot Rear Panel Management OptionsNetwork Configurations Switch Installation Preparing for Installation140F 60C Statement Hazardous Area Installation Warnings 1080 Environment and Enclosure Guidelines Installation GuidelinesNorth American Hazardous Location Approval General Guidelines Installing or Removing the Flash Memory Card Optional Verifying Package ContentsInstalling the Flash Memory Card in the Switch Connecting to a Console Port RJ-45 Console Port USB Mini-Type B Console PortConnecting the Console Cable RJ-45 Console PortUSB Mini-Type B Console Port Removing the USB Mini-Type B Console Port CoverChoose Start Control Panel Systems Tools and Equipment Connecting to PowerSupported Power Supplies Grounding the Switch DimensionsAttachable? UsageSlide the ground screw through the terminal Ground cable Connecting the Power Converter to an AC Power Source Preparing the AC Power ConnectionConnecting the AC Power Source to the Power Converter Connecting AC PowerConnecting the Power Converter to a DC Power Source Wiring the DC Power Source Statement 12 Stripping the Power Connection Wire Label14 Inserting Wires in the Power Connector 15 Torquing the Power Connector Captive Screws Attaching the Power Connectors to the Switch 16 Completed DC Power Connections on the Power Connectors17 Attaching the Power Connectors to the Switch 18 Connecting the Power Connectors to the Switch Connecting Power to the Switch PoE DC-Input Optional 332021 Powering On the Switch Applying Power to the Power ConverterRunning Boot Fast Disconnecting Power Installing the SwitchVerifying Boot Fast Installing the Switch on a DIN Rail DIN Rail SwitchRemoving the Switch from a DIN Rail Connecting Alarm Circuits Wiring the Protective Ground and DC Power for Alarm CircuitsWiring the External Alarms Label Connection21 Removing the Alarm Connector 332225 Attaching the Alarm Connector to the Switch Connecting Destination Ports 25 Connecting the Alarm Connector to the SwitchConnecting to 10/100 and 10/100/1000 Ports 26 Connecting to an Ethernet Port Installing and Removing SFP Modules Installing SFP Modules into SFP Module Slots28 Installing an SFP Module into an SFP Module Slot Removing SFP Modules from SFP Module SlotsConnecting to SFP Modules LC connector Connecting to a Dual-Purpose Port Verifying Switch Operation Where to Go NextSwitch Installation Where to Go Next Diagnosing Problems Switch Boot FastSwitch LEDs Switch ConnectionsBad or Damaged Cable Ethernet and Fiber-Optic CablesInterface Settings 10/100 and 10/100/1000 Port ConnectionsSFP Module Ping End DeviceSwitch Performance Speed, Duplex, and AutonegotiationAutonegotiation and Network Interface Cards Cabling DistanceResetting the Switch How to Recover PasswordsFinding the Switch Serial Number Serial Number Location for the Cisco IE-2000 SwitchesTechnical Specifications Operating Temperature SpecificationsEnvironmental Ranges Technical SpecificationsPower Requirements Table A-2 Cisco IE 2000 Series Technical Specifications Physical Dimensions Table A-2 Cisco IE 2000 Series Technical Specifications Alarm Ratings Alarm Ratings SpecificationHazardous Locations Standards Hazardous Locations StandardsConnector Specifications 10/100 PortsConsole Port SFP Module ConnectorsDual-Purpose Ports Alarm Port Figure B-5 USB Type A-to-USB 5-Pin Mini-Type B CableCables and Adapters SFP Module CablesCore Modal Wavelength Commercial SFPsMHz/km1 Cable Distance Extended temperature SFPs Bandwidth Type of SFP Module Nanometers Fiber TypeCable Pinouts TP3Console Port Adapter Pinouts Figure B-9Switch Console RJ-45-to-DB-25 Port DTE Adapter Device DSR DTR CTS RTSOL-25818-04 Accessing the CLI Through the Console Port Removing the USB Mini-Type B Console Port CoverFigure C-1 Removing the USB Mini-Type B Console Port Cover Figure C-2 Connecting the Console Cable Figure C-3 Connecting the USB-Mini Console Cable Installing the Cisco Microsoft Windows USB Device Driver Installing the Cisco Microsoft Windows XP USB DriverInstalling the Cisco Microsoft Windows 2000 USB Driver Uninstalling the Cisco Microsoft Windows USB Driver Using the Add or Remove Programs UtilityCompleting the Setup Program Entering the Initial Configuration InformationIP Settings Enter an enable password, and press Return These choices appear