Chapter 3 Installing and Removing Server Switch Field Replaceable Units (FRUs)
Installing a Power Supply Module
To insert a power supply, perform the following steps:
Step 1 Ground yourself using an approved ground wrist strap.
Step 2 Remove the blanking panel if one resides in the slot.
Step 3 Remove the power supply module from any packaging.
Step 4 Insert the power supply into an open slot such that the pull handle sits toward the outside of the chassis, away from the blower module. The arrow on top of the power supply or underneath the power supply must always point to the outside of the chassis.
Note The power supplies should be inserted in opposite directions of each other.
Step 5 Press the power supply firmly into the chassis.
180762
Note The power socket on the back (cable end) of the Cisco SFS 3012R Server Switch corresponds to the power supply module on the same side of the server switch.
Cisco SFS 3012R Multifabric Server Switch Hardware Installation Guide
|
| |
|