Cisco Systems SFS 3012R manual InfiniBand Port LEDs

Page 74

Chapter 5 Cisco SFS 3012R Server Switch LEDs

InfiniBand LEDs

InfiniBand Port LEDs

Two port LEDs (both green) appear next to each InfiniBand port on the switch module, as shown in Figure 5-6.

Both the top and bottom InfiniBand port LEDs are solid green. The top LED indicates a logical link has taken place. (A logical link is established when the subnet manager makes a sweep. A logical link must be established if you are to use the port.) The bottom LED indicates a physical link has occurred. (A physical link requires that the drivers on the attached InfiniBand host have been installed and are running).

Table 5-10explains InfiniBand port LED indications.

Table 5-10

Management Ethernet LED Indications

 

 

 

LED States

 

Indication

 

 

Bottom LED off

No Rx-Character detected.

 

 

Bottom LED on

Valid Rx-Character detected.

 

 

Bottom LED on, top LED on

Link is OK.

 

 

Bottom LED on, top LED off

Logical link not established.

 

 

 

Cisco SFS 3012R Multifabric Server Switch Hardware Installation Guide

5-8

OL-11187-01

 

 

Image 74
Contents Corporate Headquarters Text Part Number OL-11187-01Page N T E N T S Blower Modules Cisco SFS 3012R Server Switch LEDs OL-11187-01 Chapter Title Description AudienceOrganization Conventions Convention DescriptionStatement 1071-Warning Definition Bewaar Deze InstructiesAviso Instruções Importantes DE Segurança Warnung Wichtige SicherheitshinweiseAvvertenza Importanti Istruzioni Sulla Sicurezza Guarde Estas Instrucciones GEM Disse Anvisninger Xiii Related Documentation XivProduct Documentation DVD Ordering Documentation Obtaining DocumentationCisco.com Cisco Product Security Overview Reporting Security Problems in Cisco ProductsDocumentation Feedback Cisco Technical Support & Documentation Website Product Alerts and Field NoticesObtaining Technical Assistance Submitting a Service Request Definitions of Service Request SeverityObtaining Additional Publications and Information XixPreface Obtaining Additional Publications and Information Cisco SFS 3012R Server Switch Overview IntroductionUnified Fabric FeaturesPerformance Transparent TopologyScalability Fully Redundant System ArchitectureCisco SFS 3012R Server Switch Chassis 6 8 10 12Cisco SFS 3012R Server Switch Components Controller ModulesCisco SFS 3012R Server Switch Controller Module Ethernet and Fibre Channel Gateways Ethernet ports Ethernet gateway status LEDs Ejector handleFibre Channel Gateway Expansion Module InfiniBand Switch Modules InfiniBand Switch ModulePower Supply Modules Power Supply ModuleBlower Modules Blower ModuleOL-11187-01 Installing and Booting the Cisco SFS 3012R Server Switch SafetyOL-11187-01 Preparing for Installation Installing Cisco SFS 3012R Server Switch ComponentsMounting the Cisco SFS 3012R Server Switch on a Rack Mounting bracket Shelf railAttaching the Shelf to the Rack Positioning and Sliding the Chassis onto the Shelf Firmly tighten the shelf screws at the cable end Attaching a Serial Console Cable to a PC or Terminal Assigning a Static IP Address Obtaining an IP Address with DhcpConnecting InfiniBand Hosts Following exampleInfiniBand Cable with Pinch Connector Managing the Cisco SFS 3012R Server Switch Removing a Pinch ConnectorA P T E R Installing a Controller Module Inserting the Controller ModuleAdding or Replacing Ethernet or Fibre Channel Gateways Installing an InfiniBand Switch Module Close both fastener levers simultaneously and completely Securing an InfiniBand Switch Module Removing an InfiniBand Switch Module Installing a Power Supply Module180762 Removing a Power Supply Module Installing a Blower ModuleInserting a Power Supply Removing a Blower Module OL-11187-01 Viewing and Updating the Software Image Viewing the Software Image VersionViewing the Software Image Version with the CLI SFS-3012R#show card-inventoryViewing the Software Image Version of the Controller Module Updating the Software Image Viewing Current Image of an Individual ModuleUpdating the Software Image with the CLI This example shows the copy operationUpdating the Software Image with the Element Manager GUI Click the Import button Import File window appears Select Maintenance-Reboot Deleting a Software Image Deleting an Image with the CLISelect Maintenance File Management Deleting an Image with the Element Manager GUICisco SFS 3012R Server Switch LEDs Cisco SFS 3012R Server Switch System Status LED LED State IndicationPower Supply LEDs Power Supply LEDsBlower Module LEDs Blower Module LEDsBlower LED States Indication Controller LEDsController LED States Indication Power LED States Indication Location of Management Ethernet Port LEDsLED States Indication InfiniBand Switch Module LEDsInfiniBand LEDs InfiniBand Port LEDs Fibre Channel LEDs Fibre Channel Gateway LEDsFibre Channel Port LEDs Off Gbps Solid greenEthernet Gateway LEDs Location of Ethernet Gateway and Ethernet Port LEDsEthernet Gateway LEDs Ethernet Port LEDsGeneral Specifications Specification DetailCertifications/Regulatory Electrical SpecificationsLaser Specifications D E IN-2 IN-3 IN-4