Cisco Systems UBR10012 manual Other Electrical Problems, Ac Ok, Dc Ok, Fault

Page 24

Chapter 2 PEM Faults and Fan Assembly Failures

Other Electrical Problems

The power shelf includes three 1200-watt (W) AC-input power modules that plug into a common power backplane in the 2400W AC-input power shelf. Two 1200W AC-input power modules are capable of powering a fully configured Cisco uBR10012 router. The third power module provides full redundancy.

During normal operation, the three AC-input power modules provide automatic load-sharing with each power module supporting 33 percent of the power load. When you remove one of the AC-input power modules, the remaining power modules immediately ramp up to full power and maintain uninterrupted system power for a limited time. This allows you to replace the affected module without impacting system operations.

Faults on the 2400W AC-input power shelf can occur for the following reasons:

The AC-input power to one or more power modules has failed.

The AC power plug to one or more power modules has been removed or unplugged.

One or more power modules has failed and must be replaced.

Figure 2-4illustrates the AC PEM and its indicators. Table 2-5describes the indicators.

Figure 2-4 AC-Input Power Shelf Front Panel

DC OK AC OK FAULT

DC OK AC OK FAULT

DC OK AC OK FAULT

 

 

36137

 

 

DC OK AC OK FAULT

Table 2-5 AC-Input Power Shelf Module LEDs

 

 

 

LED

Color

Description

 

 

 

AC OK

Green

The AC-input power to the power module is present and is within the proper

 

 

range.

 

 

 

DC OK

Green

The power module is producing DC output power in the proper range.

 

 

 

FAULT

Red

This particular power module has failed and must be replaced. The 2400W

 

 

AC-input power shelf can continue operating with only two out of the three power

 

 

modules installed, but the failed module should still be replaced as soon as

 

 

possible.

 

 

 

Other Electrical Problems

If the electrical problem cannot be traced to a PEM, check the unit for:

Improper power cable connections to the Cisco uBR10012 router

Improper installation of other field-replaceable units (FRUs)

Cisco uBR10012 Universal Broadband Router Troubleshooting Guide

2-6

OL-1237-01

 

 

Image 24
Contents Corporate Headquarters Text Part Number OL-1237-01Copyright 2001-2004, Cisco Systems, Inc All rights reserved N T E N T S ARP Traffic Testing with Digital Multimeters and Cable Testers B-1 OL-1237-01 Purpose AudienceDocument Organization Related DocumentationChapter Description Obtaining Documentation Documentation FeedbackCisco.com Ordering DocumentationObtaining Technical Assistance Cisco TAC WebsiteOpening a TAC Case Obtaining Additional Publications and Information TAC Case Priority DefinitionsXii Basic Troubleshooting Checklist Basic Troubleshooting Tasks and Startup IssuesConfirming the Hardware Installation Last reset from power-on Displaying the Cisco IOS Software VersionHardware Troubleshooting Flowchart Displaying System Environment InformationCisco uBR10012 System Startup Sequence TCC+Startup Event Event Description PEM Faults and Fan Assembly Failures AC PEM FaultsFault Symptom Corrective Action Color Description DC PEM Faults DC PEM Front Panel original model, UBR10-PWR-DC 2400W AC-Input Power Shelf Other Electrical Problems FaultAC OK DC OKFan Assembly Module Faults Fan Assembly ModuleFan Assembly Air Circulation Pattern Symptom Steps to Take Single FAN FailureMULTI-FAN Failure LED OL-1237-01 Troubleshooting PRE-1 Modules PRE Module Not Supported PRE-1 Module Status ScreenMessage Description Booting Up with Redundant PRE-1 Modules IOS ProtIOS Intf IOS RUNPRE-1 Module Faults Fault Steps to Take LEDEthernet Connection Problems C10000config#interface fastethernet0/0/0Console Port Serial Connection Problems Troubleshooting Common System Problems Troubleshooting System CrashesHigh CPU Utilization Problems ARP TrafficRouterconfig-if# ip access-groupnumber Cpuhog Errors Debug and System MessagesExec and Virtual Exec Processes Invalid Scheduler Allocate Configuration Interrupts are Consuming a Large Amount of ResourcesIP Input Processing Bus Errors Problems with Access ListsSnmp Traffic Region Manager Start End Sizeb Class Media Name 0x0A000000 Memory Problems Alignment ErrorsLow Memory Errors Memory Parity ErrorsParticle Pool Fallbacks Spurious Interrupts Spurious Memory Accesses OL-1237-01 Troubleshooting Line Cards General Information for Troubleshooting Line Card Crashes Command DescriptionSIG Value SIG Name Error Reason Cache Parity Errors SigerrorSigreload Bus Errors Software-Forced Crashes Troubleshooting Line Cards TCC+ Front Panel Power MaintenanceStatus Description Fault Type Response Show controllers clock-reference command Troubleshooting the OC-12 Packet-Over-SONET Line Card Fault Corrective Action RX CARRIER-B ActiveRX CARRIER-A Enabled PASS-THROUGHEnable FailPOS SRPSync WrapPass Thru Troubleshooting the Gigabit Ethernet Line Card Gigabit Ethernet Line Card Faceplate and LED DescriptionsGigabit Ethernet Line Card Faults and Recommended Responses OL-1237-01 Password Recovery Procedure Overview Password Recovery ProcedurePress Return. The user Exec prompt appears Change all three passwords using the following commands OL-1237-01 Unsupported Commands Unsupported Frame Relay CommandsHccp Commands Mlppp CommandsUnsupported Mpls VPN Commands Unsupported PPP CommandsSpectrum Management Commands Unsupported Telco-Return CommandsOL-1237-01 Testing with Digital Multimeters and Cable Testers Equipment DescriptionTesting with TDRs and OTDRs Testing with TDRsTesting with OTDRs Testing with Network Monitors Testing with Breakout Boxes, Fox Boxes, and BERTs/BLERTsTesting with Network Analyzers Enable LED Active LEDBert BlertENABLE, OC-48 DPT/POS MAINTENANCE, OC-12 SRP/DPTMAINTENANCE, TCC+ POWER, OC-12 DPT/SRP POWER, TCC+Maintenance LED Power LEDSTATUS, OC-12 DPT/SRP STATUS, TCC+ SYNC, OC-48 DPT/POS TX, OC-48 DPT/POS WRAP, OC-48 DPT/POSOC-12 DPT/SRP TCC+ Present LED TCC+RX Carrier LED RX LED RX Pkts LEDTDR B-2 TX LED OC-48 DPT/POSWrap LED IN-6