The cable you use depends on your network speed. The switcher supports both 10 Mbps (10Base-T — Ethernet) and 100 Mbps (100Base-T — Fast Ethernet), half-duplex and full-duplex, Ethernet connections.

•• 10Base-T Ethernet requires CAT 3 or higher UTP or STP cable.

•• 100Base-T Fast Ethernet requires CAT 5e or higher UTP or STP cable.

Terminate the Ethernet cable as required:

•• Network connection — Wire as a patch (straight-through)cable.

•• Computer or control system connection — Wire as a crossover cable.

NOTE: The factory default IP address is 192.168.254.254.

EReset LED — When the unit is being reset, this LED blinks the appropriate number of times to indicate the level of reset that has been performed.

FReset button — This recessed button initiates four levels (modes) of reset. Use a pointed object such as a small Phillips screwdriver or a stylus to press and hold the Reset button while the switcher is running or being powered up.

•• Hard reset (mode 1) — Hold the Reset button while powering up the switcher to restore the DXP to the default factory conditions. This reset restores the factory-installed firmware.

NOTE: This type of reset does not clear the current configuration.

•• Events reset (mode 3) — Press and hold the Reset button for 3 seconds, then release and press it again momentarily to toggle events monitoring on and off.

•• IP settings reset (mode 4) — Press and hold the Reset button for 6 seconds, then release it and press it again momentarily to reset the switcher IP functions.

NOTE: IP settings reset does not replace any user-installed firmware.

•• Absolute reset (mode 5) — Press and hold the Reset button for 9 seconds, then release it and press it again momentarily to restore the switcher to the default factory conditions.

For more details on these reset modes, see the DXP DVI Pro and DXP HDMI User Guide, available on the provided Extron Product Software DVD or the Extron website at www.extron.com.

DXP DVI Pro and DXP HDMI Series • Setup

9

Image 15
Contents DXP Hdmi Precaucion AchtungAvertissement VorsichtFCC Class a Notice 安全须知 中文Conventions Used in this Guide Contents Vi DXP DVI Pro and DXP Hdmi Series Contents About this Guide About the DXP DVI Pro and DXP Hdmi Series Matrix SwitchersTypical DXP DVI Pro Application Application Diagram ExamplesTypical DXP Hdmi Application DXP DVI Pro and DXP Hdmi Series Introduction Setup Procedure SetupDXP DVI Pro Rear Panel Rear Panels and ConnectionsInstalling the LockIt Lacing Bracket Input connectorsRJ-45 Connector and Pinout Tables Output connectorsDXP DVI Pro and DXP Hdmi Series Setup Remote RS232/RS422 Connector Front Panel Config PortMm Connector Cable for the Configuration Port DXP DVI Pro and DXP Hdmi Series Introduction DXP Switchers Front Panel Front Panel FeaturesDXP DVI Pro and DXP Hdmi Series Operation Creating a Tie OperationsLocking and Unlocking the Front Panel Executive Modes Saving or Recalling a PresetSelecting lock mode 2 or toggling between lock modes 2 To toggle mute on and off, press and hold Viewing Ties and Muting OutputsRS-232/RS-422 and Baud Rate Display RS-232/RS-422 and Baud Rate Selection Establishing a Network Ethernet Connection Remote ControlHost-to-switcher Instructions SIS CommandsConnection Timeouts Verbose ModeMLP Edid Extended Display Identification Data720p default Edid Table DDC Source Selection SIS Value Resolution Refresh@*X#$ Command and Response Table for SIS Commands@*X# @*X#%Tie an Input to All Outputs InX@RGB@*% InX@Vid @*$ InX@AudX1 X2. . . Xn Front Panel Lock Executive Modes Edid Extended Display Identification Data CommandsX1 = X1$ X X1%A X1$ X X1%Information Requests IpsX3 IP SetupX1X1X1&X1*X$ IpiX3EX5# CV VrbX5# EX3 CG IpgX3EX4 DH IdhX4 X5* TCFactory default settings Clear all ties and presets and reset unit toSoftware Button on the Software DVD Window Installing the ProgramStarting the Program Matrix Switchers Control Program Install LinkPassword Prompt for Control Program Loading the Start-up Accessing the Html PagesPassword Prompt for Web Pages System Settings Using the Web Pages to Configure the DXPControl DXP DVI Pro and DXP Hdmi Series Remote Control Europe USA, Canada, South America Japan Central AmericaEurope, Africa, and the Middle China East Asia Middle EastExtron Europe Extron India