30 DXP DVI Pro and DXP HDMI Series • Remote Control
Command Function | ASCII Command | Response | Additional Description | |||||
(Host to Switcher) | (Switcher to Host) | |||||||
|
|
|
| |||||
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
| |
Information Requests (Continued) |
|
|
|
|
|
|
| |
Query controller firmware version | Q | X2!] |
|
|
| |||
Example: | Q | 1.23] |
|
| The | |||
|
|
|
|
| version is 1.23 (sample value only). | |||
Request system status | S | X1^•X1^•X1&•X1*•X$] |
|
|
| |||
|
|
|
|
| Display voltages X1^, internal temperature | |||
|
|
|
|
| X1&, fan speed X1*, and power supply | |||
|
|
|
|
| status X$. For X$: 0 = not OK, 1 = OK | |||
Example: | S | 3.29•4.85•+077.00•03750•1] |
| |||||
|
|
|
|
| Internal |
| ||
|
| 3.3 V Power System at 3.29 | Temperature | Power supply is on and ok. | ||||
|
|
|
|
|
|
|
| |
|
| 3.29 • 4.85 • +077.00 • 03750 • 1 | ||||||
|
|
|
|
|
|
| ||
|
| 5 V Power System at 4.85 V | Fan 1 rotating at 3750 RPM | |||||
|
|
|
|
|
|
|
| |
IP Setup |
|
|
|
|
|
|
| |
Set IP address | EX3^CI} | IpiX3^] |
|
|
| |||
Read IP address | ECI} | X3^] |
|
|
| |||
Set subnet mask | EX3^CS} | IpsX3^] |
|
|
| |||
Read subnet mask | ECS} | X3^] |
|
|
|
NOTE: X$ = Mute status for individual output | 0 = unmuted | 1 = muted |
X1^ = Voltage |
|
|
X1& = Internal temperature in degrees F |
|
|
X1* = Fan speed in RPM |
|
|
X2! | = Firmware version number to second decimal place (n.nn) |
X3^ | = IP or Gateway address or subnet mask nnn.nnn.nnn.nnn |