GRemote RS232/RS422 connector — Connect an
REMOTE
1
5
6 | RS232/RS422 |
9 |
|
Pin |
| Function |
| Function |
1 | — | Not used | — | Not used |
2 | Tx | Transmit data | Tx– | Transmit data |
3 | Rx | Receive data | Rx– | Receive data |
4 | — | Not used | — | Not used |
5 | Gnd | Signal ground | Gnd | Signal ground |
6 | — | Not used | — | Not used |
7 | — | Not used | Rx+ | Receive data (+) |
8 | — | Not used | Tx+ | Transmit data (+) |
9 | — | Not used | — | Not used |
Figure 7. Remote RS232/RS422 Connector
In the "Remote Control" section, see “SIS Commands” for definitions of some of the SIS commands (serial commands to control the switcher via this connector) and "Installing and Starting the Matrix Switchers Control Program" for details on how to install and use the control software.
Front Panel Config Port
If desired, connect a control system or computer to the front panel
•• 9600 baud
•• 8 data bits
•• 1 stop bit
•• No parity
•• No flow control
| CONTROL |
|
| I/O | |
ENTER | PRESET | VIEW | ESC | VIDEO | AUDIO |
CONFIG |
|
|
|
|
|
|
|
|
| DXP SERIES | |
|
|
| DIGITAL MATRIX SWITCHER |