Installation
Step 5: Power Module
By this point, the connectivity box must be securely fastened to the floor.
If the AVTrac system does not include the AC power module, ignore this section. To attach the AC power module, follow these instructions:
WSwitch off all electrical power before connecting the AC conduit to a junction box, and keep power off until installation is complete.
CAll electrical installation should be performed by qualified personnel in accordance with local and national electrical codes.
(F) | (J) | (D) | (E) |
Receptacles for the AC power modules are available in Australian (F), universal (J), central European (D), and French (E) models. The Australian and Universal models are provided with 24' of metal conduit, without wires (CO models). The Central European, French, and Universal models are provided with 24' of double insulated cable (ISO models).
NSome plug types are not fully compatible with the Universal Receptacle. For more details refer to the Universal AC Outlet Compatibility Guide on page 22.
Loosen the holding screws in the AC receptacle.
Insert the wire into appropriate hole and tighten the holding screws.
Snap the AC receptacle into power module.
WThe blue or black wire must be connected to the neutral slot, the brown or red wire must be connected to the live slot, and the solid green or green and yellow striped wire must be connected to the ground.
| Green |
|
Brown | or Green/ | Blue or |
Yellow | ||
or Red | (ground) | Black |
(live) |
| (neutral) |
L N
Connect wires to AC receptacle
AVTrac • Installation | 13 |