Specifications

General

Power (pass-through)

250 VAC, 50/60 Hz, 10 A (max.)

Mounting options

 

Track system (track and ramps)

 

Mountable on base flooring, beneath the finished carpet

Connectivity box

Mountable through the metal track, onto base flooring

Optional AAP plates/devices

 

Mountable in the two double-space and two triple-space Architectural Adapter Plate (AAP)

 

openings in the connectivity box

Enclosure type

Metal track base and top, metal connectivity box and cover, plastic ramps

Enclosure dimensions: see diagrams on opposite page.

Track system

 

End ramps

0.67" (1.7 cm) H x 9.36" (23.8 cm) radius, approximately 4.5° slope

Side ramps

0.67" (1.7 cm) H x 7.50" (19.0 cm) W on either side of track x 96" (243.8 cm) L, approximately 4.5°

 

slope

AVTrac 480C track base and top

 

1.03" H x 3.70" W x 96" L

 

(2.6 cm H x 9.4 cm W x 243.8 cm L)

AVTrac 480R track base and top

 

0.95" H x 3.70" W x 96" L

 

(2.4 cm H x 9.4 cm W x 243.8 cm L)

Connectivity box

3.55" (9.0 cm) H x 10.00" (25.4 cm) W x 4.91" (12.5 cm) D

Product weight

 

Parts in package 1 of 2

16.9 lbs (7.7 kg)

Parts in package 2 of 2

10.6 lbs (4.8 kg)

Shipping weight

 

Package 1 of 2

22 lbs (10 kg)

Package 2 of 2

13 lbs (6 kg)

Vibration

ISTA 1A in carton (International Safe Transit Association)

Listings

CE

Warranty

3 years parts and labor

NSpecifications are subject to change without notice.

All trademarks mentioned in this manual are the properties of their respective owners.

AVTrac • Reference Material

19

Image 21
Contents AVTrac Installation GuideSafety Instructions English PrecautionsConsignes de Sécurité Français Sicherheitsanleitungen DeutschIntroduction OverviewAVTrac Floor System Kit Contents Kit Contents Planning Before Getting StartedFloor Considerations In-Wall Cable Routing ConsiderationsWheelchair Accessibility Room ConsiderationsAVTrac maximum slope is Before Getting Started, cont’d Tools and Equipment Required for InstallationFloor InstallationRemove carpet tiles to expose concrete Cut prelaid carpet roll to expose concreteCut cable access hole in wall WallMark wall Track Cut aluminum base trackMeasure and cut track Pre-drill holes in track and ramps Track, cont’dPositions of mounting holes Pre-drill holes to secure connectivity boxMate side ramp to base track Drill into concrete and screw down trackScrew side ramps to floor Secure connectivity box to the floor Connectivity BoxConnect wires to AC receptacle Power ModuleAttach AC power module Power Module cont’dConnect double isolated cable to junction box Connect AC conduit to junction boxInstall AAPs AAPsRun cable to AAPs Ensure cables lay flat Finishing UpFit cover track Cut carpetRefit carpet Use template to cut base board Reattach base board to wallAttach carpet tile to track raceway Finishing up cont’d AVTrac installedReference Material SpecificationsAVTrac 480R Cont’dConnectivity box USA Universal AC Compatibility GuideTrack Accessories Optional AccessoriesActive AAPs Passive AAPsReference Material Extron’s Warranty Before Getting Started Quick Installation Checklist