ATTO Technology SC 5700 operation manual FastStream SC

Page 1

ATTO FastStream Storage Controller Installation and Operation Manual

FastStream SC 5300

Fibre Channel to SCSI SAN Storage Appliance

FastStream SC 5500

Fibre Channel to SAS/SATA SAN Storage Appliance

FastStream SC 5700

Fibre Channel to Fibre Channel SAN Storage Appliance

Image 1
Contents FastStream SC Atto Technology, Inc Contents Monitor Storage, Configurations Configure Storage into RAID GroupsPhone Home Email Alerts Drive Diagnostics Scsi Enclosure Services SESAppendix E Warranty Xxvi Manage Atto Devices, ConfigurationsInterface Options Appendix B Design RAID Groups XixRAID protection features FastStream 5000 Series featuresAudio/video features Additional FastStream 5300 featuresAdditional FastStream 5700 features Additional FastStream 5500 featuresFastStream SC 5300 Physical Attributes Exhibit 1.1-1 The connector side of the FastStream SC5300 Operating Temperature 5 C-40 C Reset/restore factory default switchFastStream SC 5500 Physical Attributes SAS/SATA portsLEDs on the faceplate are Cooling and airflow Fibre Channel ports FastStream SC 5700 Physical AttributesDo not block the enclosure’s vents. Page Unpacking the packing box verifying contents Install the FastStream Storage ControllerInstalling the FastStream Setting up Internet ExplorerSelect Internet Options Beginning initial configurationUncheck the Require server verification check box Before creating RAID groups Ensure Drive IntegritySelect Initialize and Verify Drives After creating RAID groups Features you may choose Configure Storage into RAID GroupsAuto-Rebuild Selecting an application Fault ToleranceInitialization Preliminary stepsAudio Quick Digital VideoGeneral Digital Video, General IT or Database Click CommitCreating a custom setup Page Page Creating a read-only user name, password Changing current user name, passwordModify System Values Changing system variablesWhen you have completed your changes, click on Commit Health and Status Monitor Monitor Storage, ConfigurationsHealth and Status Monitor page appears Scsi Enclosure Services SES Configuration DisplayConfiguration Click the Set up Error Notification buttonPhone Home Email Alerts Exhibit 6.1-1 The Error Notification Read only drive test Drive DiagnosticsClick the Read-Only Drive Test button Identifying a drive attached to the FastStream Drive performance and healthClick on Identify Drive Setting up SES Scsi Enclosure Services SESIdentifying SES elements Use the Health and Status Monitor Monitoring SES elementsUse the Manage menu Select the Monitor Enclosure Services buttonRAID group processes Modify StorageCreating RAID groups Deleting RAID groupsChanging RAID configuration RAID migration Adding mirrors to a RAID configurationAdding drives to a RAID group Modifying RAID group partitions Modifying RAID group mappingRebuilding RAID groups Click on the Modify RAID Group Mapping buttonModifying RAID options FastStream process adding or removing Hot SparesSelect the Add/Remove Hot Spares button Advanced CLI Removing RAID configuration dataPage Creating a unique name for your FastStream Manage Atto Devices, ConfigurationsDiscovering, managing other Atto devices Appliance NameClick on the System Configuration Save/Restore button Saving or restoring a configurationInterface Options Using the ExpressNAV Storage ManagerUsing Telnet Using the serial portType FastStream in the New Connection dialog box EnterClick Upload Update FirmwarePage Appendix a CLI Provides an ASCII-based Interface Symbol/Abbreviation IndicatesCLI summary CLI error messagesIii Command Default ExampleIpdhcp Command Default Example AutoMap CLI command explanationsAutoResume Boot Delay BlockDevCleanDefaultInterleave BlockDevIdentifyDumpConfiguration DriveTestConfigEmailPassword DriveTestEthernetSpeed FCPortErrorsEventLog EventLogFilterFCSCSIBusyStatus FCPortListFCTargets FCWWNameIsReserved IPSubnetMaskMaxOpTemp MetricsReadOnlyPassword PasswordResetFCPortErrors RestoreConfigurationRGAutoRebuild RGCancelAddStorageRGCommit RGCreateRGPreFetch RGWaitTimeoutRGRebuild RGResumeConversionRMStatus SaveConfigurationRoute RouteDisplaySCSIPortResetOnStartup SCSIPortResetSerialPortBaudRate SerialPortEchoDefault disabled SESDiskFailureAlarmSESEnclosures SESIdentifyTailEventLog TemperatureTime TimeZoneJbod Just a Bunch of Disks Appendix B Design RAID GroupsDvraid Digital Video RAID RAID Level 1 mirroring duplicate drives RAID Level 0 striping, no redundancyRAID Level 1 plus additional mirroring RAID Level 4 striping, one parity drive RAID Level 1+0 striping, mirror spans two drivesRAID Level 5 striping, parity distributed among drives Disk Stripe Data Appendix C Scsi Cabling Connecting Scsi devices to Scsi portsCable types Max Bits Ended SupportDeclaration of Conformity Appendix D Standards and CompliancesManufacturer limited warranty Appendix E Warranty