ATTO Technology SC 5700 operation manual Appendix a CLI Provides an ASCII-based Interface

Page 48

Appendix A CLI Provides an ASCII-based Interface

The command line interface (CLI) uses ASCII commands typed while in CLI mode.

CAUTION

Do not use CLI unless you are directed to by an ATTO technician.

Changing parameters may cause loss of data and/or disruption to performance and reliability of the FastStream.

The ExpressNAV Storage Manager is the preferred method to operate and manage the FastStream. Refer to Using the ExpressNAV Storage Manager on page 39 for details.

The command line interface (CLI) is a set of ASCII- based commands which perform configuration and diagnostic tasks. You may use them through the ExpressNAV Storage Manager Advanced CLI page (refer to Advanced CLI page on page 35) or by using the serial port interface or the Ethernet management port (refer to Interface Options on page 39).

CLI commands are context sensitive and generally follow a standard format

[GetSet] Command [Parameter1Parameter2]

followed by the return or enter key.

CLI commands are case insensitive: you may type all upper or all lower case or a mixture. Upper and lower case in this manual and the help screen are for clarification only.

Commands generally have three types of operation: get, set and immediate.

The get form returns the value of a parameter or setting and is an informational command.

Responses to get commands are followed by Ready.

The set form is an action that changes the value of a parameter or configuration setting. It may require a SaveConfiguration command and a restart of the system before it is implemented. The restart can be accomplished as part of the SaveConfiguration command or by using a separate FirmwareRestart command. A number of set commands may be issued before the SaveConfiguration command.

Responses to set commands are either an error message or Ready. *. The asterisk indicates you must use a SaveConfiguration command to finalize the set command.

Set commands which do not require a SaveConfiguration command are immediately executed.

Note

Using certain CLI commands during normal operation can cause a performance drop. Once command actions are complete, performance should return to normal levels.

Exhibit A-1 Symbols, typefaces and abbreviations used to indicate functions and elements of the command line interface used in this manual.

Symbol/Abbreviation

Indicates

 

 

 

 

-

A range (6 – 9 = 6, 7, 8, 9)

 

 

 

 

...

Indicates optional repetition of the preceding item

 

 

 

[

]

Required entry

 

 

 

 

Pick one of

 

 

 

<

>

Optional entry

 

 

BlockDevID

Index designation of a block as found by using the BlockDevScan

 

 

command

 

 

EnclosureIndex

Index designation of an enclosure found by using the SESIdentify

 

 

command

 

 

 

 

fl

Fibre Channel LUN ID (0 <= fl <= 31)

 

 

 

 

fp

Fibre Channel port number (1 <= fp <= 2)

 

 

 

i

ATTO Technology Inc. FastStream SC Installation and Operation Manual

Image 48
Contents FastStream SC Atto Technology, Inc Contents Configure Storage into RAID Groups Monitor Storage, ConfigurationsPhone Home Email Alerts Drive Diagnostics Scsi Enclosure Services SESManage Atto Devices, Configurations Appendix E Warranty XxviInterface Options Appendix B Design RAID Groups XixFastStream 5000 Series features RAID protection featuresAudio/video features Additional FastStream 5300 featuresAdditional FastStream 5500 features Additional FastStream 5700 featuresFastStream SC 5300 Physical Attributes Exhibit 1.1-1 The connector side of the FastStream SC5300 Reset/restore factory default switch Operating Temperature 5 C-40 CFastStream SC 5500 Physical Attributes SAS/SATA portsLEDs on the faceplate are FastStream SC 5700 Physical Attributes Cooling and airflow Fibre Channel portsDo not block the enclosure’s vents. Page Install the FastStream Storage Controller Unpacking the packing box verifying contentsInstalling the FastStream Setting up Internet ExplorerBeginning initial configuration Select Internet OptionsUncheck the Require server verification check box Ensure Drive Integrity Before creating RAID groupsSelect Initialize and Verify Drives After creating RAID groups Configure Storage into RAID Groups Features you may chooseAuto-Rebuild Fault Tolerance Selecting an applicationInitialization Preliminary stepsQuick Digital Video AudioGeneral Digital Video, General IT or Database Click CommitCreating a custom setup Page Page Changing current user name, password Creating a read-only user name, passwordModify System Values Changing system variablesWhen you have completed your changes, click on Commit Monitor Storage, Configurations Health and Status MonitorHealth and Status Monitor page appears Configuration Display Scsi Enclosure Services SESClick the Set up Error Notification button ConfigurationPhone Home Email Alerts Exhibit 6.1-1 The Error Notification Drive Diagnostics Read only drive testClick the Read-Only Drive Test button Drive performance and health Identifying a drive attached to the FastStreamClick on Identify Drive Scsi Enclosure Services SES Setting up SESIdentifying SES elements Monitoring SES elements Use the Health and Status MonitorSelect the Monitor Enclosure Services button Use the Manage menuModify Storage RAID group processesCreating RAID groups Deleting RAID groupsAdding mirrors to a RAID configuration Changing RAID configuration RAID migrationAdding drives to a RAID group Modifying RAID group mapping Modifying RAID group partitionsRebuilding RAID groups Click on the Modify RAID Group Mapping buttonFastStream process adding or removing Hot Spares Modifying RAID optionsSelect the Add/Remove Hot Spares button Removing RAID configuration data Advanced CLIPage Manage Atto Devices, Configurations Creating a unique name for your FastStreamDiscovering, managing other Atto devices Appliance NameSaving or restoring a configuration Click on the System Configuration Save/Restore buttonUsing the ExpressNAV Storage Manager Interface OptionsUsing the serial port Using TelnetType FastStream in the New Connection dialog box EnterUpdate Firmware Click UploadPage Symbol/Abbreviation Indicates Appendix a CLI Provides an ASCII-based InterfaceCLI error messages CLI summaryCommand Default Example IiiIpdhcp Command Default Example CLI command explanations AutoMapAutoResume BlockDevClean Boot DelayDefaultInterleave BlockDevIdentifyDriveTestConfig DumpConfigurationEmailPassword DriveTestFCPortErrors EthernetSpeedEventLog EventLogFilterFCPortList FCSCSIBusyStatusFCTargets FCWWNameIPSubnetMask IsReservedMaxOpTemp MetricsPassword ReadOnlyPasswordResetFCPortErrors RestoreConfigurationRGCancelAddStorage RGAutoRebuildRGCommit RGCreateRGWaitTimeout RGPreFetchRGRebuild RGResumeConversionSaveConfiguration RMStatusRoute RouteDisplaySCSIPortReset SCSIPortResetOnStartupSerialPortBaudRate SerialPortEchoSESDiskFailureAlarm Default disabledSESEnclosures SESIdentifyTemperature TailEventLogTime TimeZoneAppendix B Design RAID Groups Jbod Just a Bunch of DisksDvraid Digital Video RAID RAID Level 0 striping, no redundancy RAID Level 1 mirroring duplicate drivesRAID Level 1 plus additional mirroring RAID Level 1+0 striping, mirror spans two drives RAID Level 4 striping, one parity driveRAID Level 5 striping, parity distributed among drives Disk Stripe Data Connecting Scsi devices to Scsi ports Appendix C Scsi CablingCable types Support Max Bits EndedAppendix D Standards and Compliances Declaration of ConformityAppendix E Warranty Manufacturer limited warranty