ATTO Technology SC 5700 operation manual FastStream SC 5500 Physical Attributes, SAS/SATA ports

Page 10

1.2 FastStream SC 5500 Physical Attributes

The ATTO FastStream SC 5500 is a Fibre Channel to SAS/SATA SAN storage appliance which can be seamlessly integrated into a new or an existing storage environment.

The ATTO FastStream SC 5500 is available in a desktop model, an industry-standard 1U form factor for easy integration into racks and as an embeddable board-level product.

For installation instructions for the desktop and 1U form factor models, refer to Install the FastStream Storage Controller on page 9.

For installation instructions and physical attribute details for the embeddable model, refer to the ATTO Embedded Storage Controller Installation and Operation manual.

Dimensions

Width: 17.31 inches

Length: 9.9 inches

Height: 1.69 inches (1U)

Weight: approximately 8 pounds

Cooling and airflow

Operating Temperature: 5 °C-40 °C

Humidity: 10-90% non-condensing

CAUTION

Do not block the enclosure’s vents. The FastStream does not allow data transfer if overheating occurs. Ambient air should not exceed 40 °C.

Explosionsgefahr, wenn die Batterie falsch entfernt und/oder ersetzt wird. Entsorgen Sie benutzte Batterien in Übereinstimmung mit Ihren lokalen Umweltschutzbestimmungen.

Fibre Channel ports

The two independent 4-Gigabit Fibre Channel ports connect the FastStream SC 7500 to Fibre Channel hosts using optical SFP connectors and multimode fiber optic cable.

Make sure all cables are anchored securely at both ends with the proper connectors.

SAS/SATA ports

The two (x4) 3-Gb SAS/SATA ports connect storage devices into the Storage Area Network (SAN) using mini SAS 4x cable plug connectors.

Management ports

Management is provided using the 10/100/1000 base T Ethernet port accessible from the RJ-45 connector or the RS-232 serial port using an RJ-11 connector.

(See Exhibit 1.2-1).

Power

Input voltage: 100-240 VAC, 2.5A, 47-63 Hz

Battery-backed event log: A rechargeable Lithium ion battery cell holds the event log memory for up to 30 days. If the FastStream has been disconnected from power, recharging begins automatically when power is restored to the system. The battery is fully charged after 36 hours of continuous power application.

WARNING WARNING

Risk of explosion if battery is removed and/or replaced by an incorrect type. Dispose of used batteries in accordance with your local environmental regulations.

Reset/restore factory default switch

To reset the FastStream, briefly insert a tool in the hole in the back panel for less than three seconds. See Exhibit 1.2-1.

To restore factory defaults, insert the tool in the hole in the back panel for more than four seconds until the green Ready LED blinks.

LED indicators

The LED indicators can be viewed from the connector side and the front side of the FastStream. (See Exhibit 1.2-2 and Exhibit 1.2-3)

LEDs on the connector side are: Ready/Fault LED lights green to indicate ready, lights yellow to show a faulted condition, and is off to indicate not ready.

5

ATTO Technology Inc. FastStream SC Installation and Operation Manual

Image 10
Contents FastStream SC Atto Technology, Inc Contents Phone Home Email Alerts Drive Diagnostics Configure Storage into RAID GroupsMonitor Storage, Configurations Scsi Enclosure Services SESInterface Options Manage Atto Devices, ConfigurationsAppendix E Warranty Xxvi Appendix B Design RAID Groups XixAudio/video features FastStream 5000 Series featuresRAID protection features Additional FastStream 5300 featuresAdditional FastStream 5500 features Additional FastStream 5700 featuresFastStream SC 5300 Physical Attributes Exhibit 1.1-1 The connector side of the FastStream SC5300 FastStream SC 5500 Physical Attributes Reset/restore factory default switchOperating Temperature 5 C-40 C SAS/SATA portsLEDs on the faceplate are Cooling and airflow Fibre Channel ports FastStream SC 5700 Physical AttributesDo not block the enclosure’s vents. Page Installing the FastStream Install the FastStream Storage ControllerUnpacking the packing box verifying contents Setting up Internet ExplorerSelect Internet Options Beginning initial configurationUncheck the Require server verification check box Before creating RAID groups Ensure Drive IntegritySelect Initialize and Verify Drives After creating RAID groups Features you may choose Configure Storage into RAID GroupsAuto-Rebuild Initialization Fault ToleranceSelecting an application Preliminary stepsGeneral Digital Video, General IT or Database Quick Digital VideoAudio Click CommitCreating a custom setup Page Page Modify System Values Changing current user name, passwordCreating a read-only user name, password Changing system variablesWhen you have completed your changes, click on Commit Health and Status Monitor Monitor Storage, ConfigurationsHealth and Status Monitor page appears Configuration Display Scsi Enclosure Services SESConfiguration Click the Set up Error Notification buttonPhone Home Email Alerts Exhibit 6.1-1 The Error Notification Read only drive test Drive DiagnosticsClick the Read-Only Drive Test button Identifying a drive attached to the FastStream Drive performance and healthClick on Identify Drive Scsi Enclosure Services SES Setting up SESIdentifying SES elements Monitoring SES elements Use the Health and Status MonitorSelect the Monitor Enclosure Services button Use the Manage menuCreating RAID groups Modify StorageRAID group processes Deleting RAID groupsChanging RAID configuration RAID migration Adding mirrors to a RAID configurationAdding drives to a RAID group Rebuilding RAID groups Modifying RAID group mappingModifying RAID group partitions Click on the Modify RAID Group Mapping buttonModifying RAID options FastStream process adding or removing Hot SparesSelect the Add/Remove Hot Spares button Removing RAID configuration data Advanced CLIPage Discovering, managing other Atto devices Manage Atto Devices, ConfigurationsCreating a unique name for your FastStream Appliance NameSaving or restoring a configuration Click on the System Configuration Save/Restore buttonUsing the ExpressNAV Storage Manager Interface OptionsType FastStream in the New Connection dialog box Using the serial portUsing Telnet EnterUpdate Firmware Click UploadPage Symbol/Abbreviation Indicates Appendix a CLI Provides an ASCII-based InterfaceCLI error messages CLI summaryCommand Default Example IiiIpdhcp Command Default Example AutoMap CLI command explanationsAutoResume DefaultInterleave BlockDevCleanBoot Delay BlockDevIdentifyEmailPassword DriveTestConfigDumpConfiguration DriveTestEventLog FCPortErrorsEthernetSpeed EventLogFilterFCTargets FCPortListFCSCSIBusyStatus FCWWNameMaxOpTemp IPSubnetMaskIsReserved MetricsResetFCPortErrors PasswordReadOnlyPassword RestoreConfigurationRGCommit RGCancelAddStorageRGAutoRebuild RGCreateRGRebuild RGWaitTimeoutRGPreFetch RGResumeConversionRoute SaveConfigurationRMStatus RouteDisplaySerialPortBaudRate SCSIPortResetSCSIPortResetOnStartup SerialPortEchoSESEnclosures SESDiskFailureAlarmDefault disabled SESIdentifyTime TemperatureTailEventLog TimeZoneJbod Just a Bunch of Disks Appendix B Design RAID GroupsDvraid Digital Video RAID RAID Level 1 mirroring duplicate drives RAID Level 0 striping, no redundancyRAID Level 1 plus additional mirroring RAID Level 4 striping, one parity drive RAID Level 1+0 striping, mirror spans two drivesRAID Level 5 striping, parity distributed among drives Disk Stripe Data Appendix C Scsi Cabling Connecting Scsi devices to Scsi portsCable types Support Max Bits EndedAppendix D Standards and Compliances Declaration of ConformityAppendix E Warranty Manufacturer limited warranty