ATTO Technology SC 5700 operation manual CLI error messages, CLI summary

Page 49

Symbol/Abbreviation

Indicates

 

 

GroupName

The name of the RAID group, designated by the user, to which a block

 

device is assigned. Use RGDisplay to discover RAID group names

 

 

MemberIndex

Index designation of a RAID group member as found by using the

 

RMStatus command

 

 

mp1

Ethernet port used to manage the FastStream

 

 

PartitionIndex

Index designation of a partition as found by using the PartitionDisplay

 

command

 

 

CLI error messages

The following error messages may be returned by the Command line Interface:

ERROR. Invalid Command. Type 'Help' for command list.

ERROR. Wrong/Missing Parameters

Usage: <usage string>

ERROR Invalid RAID Group state

ERROR Invalid Block Device index

ERROR Invalid RAID MemberIdx

ERROR Maximum number of RAID Groups exceeded

ERROR Insufficient number of RAID Group members

ERROR

Block Device at specified index no longer available

ERROR Insufficient RAID Group members for RAID type

CLI summary

The following chart summarizes the Command Line Interface commands, their defaults, and an example of how to enter the commands. Commands which have no default values have a blank entry in that column of the table.

CAUTION

Do not use CLI unless you are directed to by an ATTO technician.

Changing parameters may cause loss of data and/or disruption to performance and reliability of the FastStream.

The ExpressNAV Storage Manager is the preferred method to operate and manage the FastStream. Refer to Interface Options on page 39 for details.

Command

Default

Example

 

 

 

AutoMap

 

automap

 

 

 

AutoResume

initialization = enabled

set autoresume all disabled

 

rebuild = enabled

 

 

erase = disabled

 

 

 

 

BlockDevClean

 

blockdevclean 30

 

 

 

BlockDevIdentify

 

blockdevidentify 30

 

 

 

BlockDevIDStop

 

blockdevidstop

 

 

 

BlockDevScan

 

blockdevscan

 

 

 

BootDelay

5

set bootdelay 25

 

 

 

ii

Image 49
Contents FastStream SC Atto Technology, Inc Contents Monitor Storage, Configurations Configure Storage into RAID GroupsPhone Home Email Alerts Drive Diagnostics Scsi Enclosure Services SESAppendix E Warranty Xxvi Manage Atto Devices, ConfigurationsInterface Options Appendix B Design RAID Groups XixRAID protection features FastStream 5000 Series featuresAudio/video features Additional FastStream 5300 featuresAdditional FastStream 5700 features Additional FastStream 5500 featuresFastStream SC 5300 Physical Attributes Exhibit 1.1-1 The connector side of the FastStream SC5300 Operating Temperature 5 C-40 C Reset/restore factory default switchFastStream SC 5500 Physical Attributes SAS/SATA portsLEDs on the faceplate are Cooling and airflow Fibre Channel ports FastStream SC 5700 Physical AttributesDo not block the enclosure’s vents. Page Unpacking the packing box verifying contents Install the FastStream Storage ControllerInstalling the FastStream Setting up Internet ExplorerSelect Internet Options Beginning initial configurationUncheck the Require server verification check box Before creating RAID groups Ensure Drive IntegritySelect Initialize and Verify Drives After creating RAID groups Features you may choose Configure Storage into RAID GroupsAuto-Rebuild Selecting an application Fault ToleranceInitialization Preliminary stepsAudio Quick Digital VideoGeneral Digital Video, General IT or Database Click CommitCreating a custom setup Page Page Creating a read-only user name, password Changing current user name, passwordModify System Values Changing system variablesWhen you have completed your changes, click on Commit Health and Status Monitor Monitor Storage, ConfigurationsHealth and Status Monitor page appears Scsi Enclosure Services SES Configuration DisplayConfiguration Click the Set up Error Notification buttonPhone Home Email Alerts Exhibit 6.1-1 The Error Notification Read only drive test Drive DiagnosticsClick the Read-Only Drive Test button Identifying a drive attached to the FastStream Drive performance and healthClick on Identify Drive Setting up SES Scsi Enclosure Services SESIdentifying SES elements Use the Health and Status Monitor Monitoring SES elementsUse the Manage menu Select the Monitor Enclosure Services buttonRAID group processes Modify StorageCreating RAID groups Deleting RAID groupsChanging RAID configuration RAID migration Adding mirrors to a RAID configurationAdding drives to a RAID group Modifying RAID group partitions Modifying RAID group mappingRebuilding RAID groups Click on the Modify RAID Group Mapping buttonModifying RAID options FastStream process adding or removing Hot SparesSelect the Add/Remove Hot Spares button Advanced CLI Removing RAID configuration dataPage Creating a unique name for your FastStream Manage Atto Devices, ConfigurationsDiscovering, managing other Atto devices Appliance NameClick on the System Configuration Save/Restore button Saving or restoring a configurationInterface Options Using the ExpressNAV Storage ManagerUsing Telnet Using the serial portType FastStream in the New Connection dialog box EnterClick Upload Update FirmwarePage Appendix a CLI Provides an ASCII-based Interface Symbol/Abbreviation IndicatesCLI summary CLI error messagesIii Command Default ExampleIpdhcp Command Default Example AutoMap CLI command explanationsAutoResume Boot Delay BlockDevCleanDefaultInterleave BlockDevIdentifyDumpConfiguration DriveTestConfigEmailPassword DriveTestEthernetSpeed FCPortErrorsEventLog EventLogFilterFCSCSIBusyStatus FCPortListFCTargets FCWWNameIsReserved IPSubnetMaskMaxOpTemp MetricsReadOnlyPassword PasswordResetFCPortErrors RestoreConfigurationRGAutoRebuild RGCancelAddStorageRGCommit RGCreateRGPreFetch RGWaitTimeoutRGRebuild RGResumeConversionRMStatus SaveConfigurationRoute RouteDisplaySCSIPortResetOnStartup SCSIPortResetSerialPortBaudRate SerialPortEchoDefault disabled SESDiskFailureAlarmSESEnclosures SESIdentifyTailEventLog TemperatureTime TimeZoneJbod Just a Bunch of Disks Appendix B Design RAID GroupsDvraid Digital Video RAID RAID Level 1 mirroring duplicate drives RAID Level 0 striping, no redundancyRAID Level 1 plus additional mirroring RAID Level 4 striping, one parity drive RAID Level 1+0 striping, mirror spans two drivesRAID Level 5 striping, parity distributed among drives Disk Stripe Data Appendix C Scsi Cabling Connecting Scsi devices to Scsi portsCable types Max Bits Ended SupportDeclaration of Conformity Appendix D Standards and CompliancesManufacturer limited warranty Appendix E Warranty