ATTO Technology SC 5700 operation manual Iii, Command Default Example

Page 50

Command

Default

Example

 

 

 

BridgeModel

 

get bridgemodel

 

 

 

BridgeName

“ “

set bridgename Omega6

 

 

 

ClearEventLog

 

cleareventlog

 

 

 

Date

 

set date 03/03/2003

 

 

 

DefaultInterleave

128

set defaultinterleave 64

 

 

 

DeleteAllMaps

 

deleteallmaps

 

 

 

DisplayEventLog

 

displayeventlog

 

 

 

DisplayEventLogFilter

all all all

set displayeventlogfilter gen info all

 

 

 

DriveTest

 

drivetest begin

 

 

 

DriveTestConfig

 

set drivetestconfig read

 

 

 

DriveTestList

 

set drivetestlist all

 

 

 

DriveTestStatus

 

get driveteststatus

 

 

 

DumpConfiguration

 

dumpconfiguration

 

 

 

DumpEventLog

 

dumpeventlog

 

 

 

EmailFromAddress

 

set emailfromaddress

 

 

 

EmailNotify

disabled

set emailnotify enabled

 

 

 

EmailNotifyAddress

 

get emailnotifyaddress

 

 

 

EmailPassword

 

set emailpassword

 

 

 

EmailServerAddress

0.0.0.0

get emailserveraddress

 

 

 

EmailUsername

 

get emailusername

 

 

 

EthernetSpeed

auto

set ethernetspeed mp1 100

 

 

 

EventLog

enabled

set eventlog disabled

 

 

 

EventLogFilter

all all all

set eventlogfilter gen info all

 

 

 

Exit

 

exit

 

 

 

FCConnMode

loop

set fcconnmode all ptp

 

 

 

FCDataRate

auto

get fcdatarate all

 

 

 

FCHard

disabled

set fchard enabled

 

 

 

FCHardAddress

fp1=3; fp2=4

set fchardaddress 1 122

 

fp3=5, fp4=6

 

 

 

 

FCMultiNode

disabled

set fcmultinode enabled

 

 

 

FCPortErrors

 

get fcporterrors all

 

 

 

FCPortList

 

fcportlist

 

 

 

FCSCSIBusyStatus (SC 5300)

busy

set fcscsibusystatus qfull

 

 

 

FCTargets (SC 5700, 7700)

 

fctargets

 

 

 

FCWWName

 

get fcwwname 1

 

 

 

FirmwareRestart

 

firmwarerestart

 

 

 

Help

 

help driveinfo

 

 

 

HSAdd

 

hsadd 3

 

 

 

HSDisplay

 

hsdisplay

 

 

 

iii

ATTO Technology Inc. FastStream SC Installation and Operation Manual

Image 50
Contents FastStream SC Atto Technology, Inc Contents Phone Home Email Alerts Drive Diagnostics Configure Storage into RAID GroupsMonitor Storage, Configurations Scsi Enclosure Services SESInterface Options Manage Atto Devices, ConfigurationsAppendix E Warranty Xxvi Appendix B Design RAID Groups XixAudio/video features FastStream 5000 Series featuresRAID protection features Additional FastStream 5300 featuresAdditional FastStream 5500 features Additional FastStream 5700 featuresFastStream SC 5300 Physical Attributes Exhibit 1.1-1 The connector side of the FastStream SC5300 FastStream SC 5500 Physical Attributes Reset/restore factory default switchOperating Temperature 5 C-40 C SAS/SATA portsLEDs on the faceplate are Do not block the enclosure’s vents. FastStream SC 5700 Physical AttributesCooling and airflow Fibre Channel ports Page Installing the FastStream Install the FastStream Storage ControllerUnpacking the packing box verifying contents Setting up Internet ExplorerUncheck the Require server verification check box Beginning initial configurationSelect Internet Options Select Initialize and Verify Drives Ensure Drive IntegrityBefore creating RAID groups After creating RAID groups Auto-Rebuild Configure Storage into RAID GroupsFeatures you may choose Initialization Fault ToleranceSelecting an application Preliminary stepsGeneral Digital Video, General IT or Database Quick Digital VideoAudio Click CommitCreating a custom setup Page Page Modify System Values Changing current user name, passwordCreating a read-only user name, password Changing system variablesWhen you have completed your changes, click on Commit Health and Status Monitor page appears Monitor Storage, ConfigurationsHealth and Status Monitor Configuration Display Scsi Enclosure Services SESPhone Home Email Alerts Click the Set up Error Notification buttonConfiguration Exhibit 6.1-1 The Error Notification Click the Read-Only Drive Test button Drive DiagnosticsRead only drive test Click on Identify Drive Drive performance and healthIdentifying a drive attached to the FastStream Scsi Enclosure Services SES Setting up SESIdentifying SES elements Monitoring SES elements Use the Health and Status MonitorSelect the Monitor Enclosure Services button Use the Manage menuCreating RAID groups Modify StorageRAID group processes Deleting RAID groupsAdding drives to a RAID group Adding mirrors to a RAID configurationChanging RAID configuration RAID migration Rebuilding RAID groups Modifying RAID group mappingModifying RAID group partitions Click on the Modify RAID Group Mapping buttonSelect the Add/Remove Hot Spares button FastStream process adding or removing Hot SparesModifying RAID options Removing RAID configuration data Advanced CLIPage Discovering, managing other Atto devices Manage Atto Devices, ConfigurationsCreating a unique name for your FastStream Appliance NameSaving or restoring a configuration Click on the System Configuration Save/Restore buttonUsing the ExpressNAV Storage Manager Interface OptionsType FastStream in the New Connection dialog box Using the serial portUsing Telnet EnterUpdate Firmware Click UploadPage Symbol/Abbreviation Indicates Appendix a CLI Provides an ASCII-based InterfaceCLI error messages CLI summaryCommand Default Example IiiIpdhcp Command Default Example AutoResume CLI command explanationsAutoMap DefaultInterleave BlockDevCleanBoot Delay BlockDevIdentifyEmailPassword DriveTestConfigDumpConfiguration DriveTestEventLog FCPortErrorsEthernetSpeed EventLogFilterFCTargets FCPortListFCSCSIBusyStatus FCWWNameMaxOpTemp IPSubnetMaskIsReserved MetricsResetFCPortErrors PasswordReadOnlyPassword RestoreConfigurationRGCommit RGCancelAddStorageRGAutoRebuild RGCreateRGRebuild RGWaitTimeoutRGPreFetch RGResumeConversionRoute SaveConfigurationRMStatus RouteDisplaySerialPortBaudRate SCSIPortResetSCSIPortResetOnStartup SerialPortEchoSESEnclosures SESDiskFailureAlarmDefault disabled SESIdentifyTime TemperatureTailEventLog TimeZoneDvraid Digital Video RAID Appendix B Design RAID GroupsJbod Just a Bunch of Disks RAID Level 1 plus additional mirroring RAID Level 0 striping, no redundancyRAID Level 1 mirroring duplicate drives RAID Level 5 striping, parity distributed among drives RAID Level 1+0 striping, mirror spans two drivesRAID Level 4 striping, one parity drive Disk Stripe Data Cable types Connecting Scsi devices to Scsi portsAppendix C Scsi Cabling Support Max Bits EndedAppendix D Standards and Compliances Declaration of ConformityAppendix E Warranty Manufacturer limited warranty