ATTO Technology SC 5700 SCSIPortList, SCSIPortResetOnStartup, SCSIPortSyncTransfer

Page 63

SCSIPortList

SC 5300

Lists the status of all available SCSI ports.

SCSIPortList

SCSIPortReset

SC 5300

Resets the specified SCSI bus.

SCSIPortReset [sb]

SCSIPortResetOnStartup

SC 5300

Controls whether the specified SCSI bus is reset each time the unit is powered up.

Default: enabled

set SCSIPortResetOnStartup [sb] [enabled disabled] get SCSIPortResetOnStartup [sb]

SCSIPortSyncTransfer

SC 5300

Controls the unit’s attempts to negotiate synchronous SCSI transfers with devices on the specified bus.

Default: enabled

set SCSIPortSyncTransfer [sb] [enabled disabled] get SCSIPortSyncTransfer [sb]

SCSIPortTermination

SC 5300

Configures the SCSI internal termination of the specified SCSI port. Enabling termination allows the unit to act as a terminator at the end of a SCSI chain.

Default: enabled

set SCSIPortTermination [sb] [enabled disabled] get SCSIPortTermination [sb]

SCSIPortWideTransfer

SC 5300

Controls the unit’s attempts to negotiate wide SCSI transfers with devices on the specified bus.

Default: enabled

set SCSIPortWideTransfer [sb] [enabled disabled] get SCSIPortWideTransfer [sb]

SCSITargetLUNs

SC 5300

Controls the maximum number of SCSI LUNs per target the unit queries during a SCSI bus scan.

Default: 8

set SCSITargetLUNs [sb] [8 64] get SCSITargetLUNs [sb]

SCSITargets

SC 5300

Lists the physical devices that are connected and running on the specified SCSI port.

SCSITargets [sb]

SerialNumber

Displays the serial number of the unit. The serial number is a 13 character field. The first seven alphanumeric characters are an abbreviation representing the product name. The remaining six digits are the individual unit’s number.

get SerialNumber

SerialPortBaudRate

Configures the baud rate for the unit’s RS-232 serial port. The number of data bits per character is fixed at 8 with no parity.

Default: 115200

set SerialPortBaudRate [9600 19200 38400 57600 115200]

SaveConfiguration Restart command required get SerialPortBaudRate

SerialPortEcho

Controls if the unit echoes characters on its RS-232 port. When enabled, all non-control character keyboard input is output to the display.

Default: enabled

set SerialPortEcho [enabled disabled] get SerialPortEcho

SES

SC 5500, SC 5700

Enables support for SES enclosures that have been discovered by the appliance.

Default: enabled

set SES [enabled disabled] get SES

SESAlarmTest

SC 5500, SC 5700

Turns on the specified enclosure's audible alarm at the specified warning level. Reset turns off the alarm.

Note

The SESEnclosures command must be executed before executing

SESAlarmTest [EnclosureIndex] [SET RESET] [INFO

NON-CRIT CRIT UNRECOV]

xvi

Image 63
Contents FastStream SC Atto Technology, Inc Contents Scsi Enclosure Services SES Configure Storage into RAID GroupsMonitor Storage, Configurations Phone Home Email Alerts Drive DiagnosticsAppendix B Design RAID Groups Xix Manage Atto Devices, ConfigurationsAppendix E Warranty Xxvi Interface OptionsAdditional FastStream 5300 features FastStream 5000 Series featuresRAID protection features Audio/video featuresAdditional FastStream 5700 features Additional FastStream 5500 featuresFastStream SC 5300 Physical Attributes Exhibit 1.1-1 The connector side of the FastStream SC5300 SAS/SATA ports Reset/restore factory default switchOperating Temperature 5 C-40 C FastStream SC 5500 Physical AttributesLEDs on the faceplate are FastStream SC 5700 Physical Attributes Cooling and airflow Fibre Channel portsDo not block the enclosure’s vents. Page Setting up Internet Explorer Install the FastStream Storage ControllerUnpacking the packing box verifying contents Installing the FastStreamBeginning initial configuration Select Internet OptionsUncheck the Require server verification check box Ensure Drive Integrity Before creating RAID groupsSelect Initialize and Verify Drives After creating RAID groups Configure Storage into RAID Groups Features you may chooseAuto-Rebuild Preliminary steps Fault ToleranceSelecting an application InitializationClick Commit Quick Digital VideoAudio General Digital Video, General IT or DatabaseCreating a custom setup Page Page Changing system variables Changing current user name, passwordCreating a read-only user name, password Modify System ValuesWhen you have completed your changes, click on Commit Monitor Storage, Configurations Health and Status MonitorHealth and Status Monitor page appears Scsi Enclosure Services SES Configuration DisplayClick the Set up Error Notification button ConfigurationPhone Home Email Alerts Exhibit 6.1-1 The Error Notification Drive Diagnostics Read only drive testClick the Read-Only Drive Test button Drive performance and health Identifying a drive attached to the FastStreamClick on Identify Drive Setting up SES Scsi Enclosure Services SESIdentifying SES elements Use the Health and Status Monitor Monitoring SES elementsUse the Manage menu Select the Monitor Enclosure Services buttonDeleting RAID groups Modify StorageRAID group processes Creating RAID groupsAdding mirrors to a RAID configuration Changing RAID configuration RAID migrationAdding drives to a RAID group Click on the Modify RAID Group Mapping button Modifying RAID group mappingModifying RAID group partitions Rebuilding RAID groupsFastStream process adding or removing Hot Spares Modifying RAID optionsSelect the Add/Remove Hot Spares button Advanced CLI Removing RAID configuration dataPage Appliance Name Manage Atto Devices, ConfigurationsCreating a unique name for your FastStream Discovering, managing other Atto devicesClick on the System Configuration Save/Restore button Saving or restoring a configurationInterface Options Using the ExpressNAV Storage ManagerEnter Using the serial portUsing Telnet Type FastStream in the New Connection dialog boxClick Upload Update FirmwarePage Appendix a CLI Provides an ASCII-based Interface Symbol/Abbreviation IndicatesCLI summary CLI error messagesIii Command Default ExampleIpdhcp Command Default Example CLI command explanations AutoMapAutoResume BlockDevIdentify BlockDevCleanBoot Delay DefaultInterleaveDriveTest DriveTestConfigDumpConfiguration EmailPasswordEventLogFilter FCPortErrorsEthernetSpeed EventLogFCWWName FCPortListFCSCSIBusyStatus FCTargetsMetrics IPSubnetMaskIsReserved MaxOpTempRestoreConfiguration PasswordReadOnlyPassword ResetFCPortErrors RGCreate RGCancelAddStorage RGAutoRebuild RGCommitRGResumeConversion RGWaitTimeoutRGPreFetch RGRebuildRouteDisplay SaveConfigurationRMStatus RouteSerialPortEcho SCSIPortResetSCSIPortResetOnStartup SerialPortBaudRateSESIdentify SESDiskFailureAlarmDefault disabled SESEnclosuresTimeZone TemperatureTailEventLog TimeAppendix B Design RAID Groups Jbod Just a Bunch of DisksDvraid Digital Video RAID RAID Level 0 striping, no redundancy RAID Level 1 mirroring duplicate drivesRAID Level 1 plus additional mirroring RAID Level 1+0 striping, mirror spans two drives RAID Level 4 striping, one parity driveRAID Level 5 striping, parity distributed among drives Disk Stripe Data Connecting Scsi devices to Scsi ports Appendix C Scsi CablingCable types Max Bits Ended SupportDeclaration of Conformity Appendix D Standards and CompliancesManufacturer limited warranty Appendix E Warranty