3.1 Diamond-VT Components

The Diamond-VT has been designed to be easy to use, maintain and upgrade. It features a durable steel outer case and modular components in either a floor or a rack mount model.

Immediately upon receipt, check the shipping carton for damage from mishandling. Contact us at once via the means that is easiest for you (see Warranty on page A-xv)if the carton has been mishandled or displays any signs of damage.

The front of the Diamond-VT provides access to the management card and disk drive sleds. The

rear of the unit holds the host interface cards, power supplies and blower assemblies.

CAUTION

All modular components must be replaced by qualified personnel only. Refer to Hot Swap Operating Instructions on page 69.

Floor model

The management system card is at the top front of the case. At its center is a DB-9 serial RS-232 port, a connection for setup, monitoring and upgrade of the unit from any computer system with an RS-232 interface. The optional 10/100 BaseT Ethernet management services card enables Telnet-based monitoring and management. It also provides the ability to update the firmware in the array via FTP.

LEDs to the port’s right indicate fault, unit ready, host interface cards A and B installation status, and the power status for each power supply.

Below the management system card are individual disk drive sleds which also have LEDs for each drive’s status. Each sled contains two hard drives. Up to 24 hard drives may be installed on the 12 sleds. Empty bays should be covered by blank faceplates

or empty sleds. Access is provided by loosening two screws and gently pulling on the sled handle.

On the rear of the unit are blowers which support hard drive, cabinet and power supply cooling. The blowers are held in by removable screws. Correct operation is displayed by a LED at the top of each panel.

The power supplies for the Diamond-VT, also in the rear of the unit, are accessible by loosening two screws and pulling on the power supply module handle. The power standby on/off switch is at the top of each module. A yellow LED indicates caution and a green LED indicates on. The power cord socket is at the bottom of each power supply.

Between the power supplies and blower assemblies are two slots that hold the Host Interface cards. The HIC is the connection point into the Diamond-VT and is available in a 2- Gigabit Fibre Channel or Ultra 160 SCSI. Host Interface cards have fault and on-lineor fault and activity LED indicators, depending on the model. SCSI The SCSI card faceplate has a rotary binary-coded hex switch to set the SCSI ID of the Diamond-VT. The SCSI card also has an in channel, to connect via cable to the unit’s communication source, and an out channel, available for daisy-chaining arrays together or to complete termination using an external LVD terminator.

7

ATTO Technology Inc. Diamond Storage Array Installation and Operation Manual

Image 18
Contents Diamond Storage Array VT-Class Page Page Contents Atto ExpressNAV Browser-based Interface ExpressNAV PagesMaintenance Services Commands Fibre Channel Configuration CommandsSerial Port Configuration Commands Diagnostic CommandsDrive Management Commands ECCResetting Defaults Configuring the Diamond-VTDiagnostics, Upgrade and Maintenance Troubleshooting Virtual TapeAppendix F Product Safety Xiii Appendix D Sample Zoning Command SequencesAppendix E Specifications Xii Appendix G Part numbers Xiv Appendix H WarrantyPreface DisclaimerAtto Technology, Inc Page Diamond-VT features Diamond Storage Array-VT Product OverviewFibre Channel model Scsi modelEthernet Diamond-VT Technical OverviewRS-232 400MB/secAdxt Powers ATA to New Levels ATA Interface Engine AIE The interface to eachSet up the Ethernet connection Installation InstructionsPhysical setup Connect to EthernetConnect to Ethernet, on page 5, follow Set up Virtual Tape configurationConfiguration examples RAID Level 10 with Hot Spare sledsDiamond-VT Components Floor modelRack mount model Diamond-VT Physical Setup Floor ModelRack Mount Physical setup Connecting a Fibre Channel Array AutoconfigurationManual configuration Fibre Channel connections Bus speed, MB/sec Bus width Max. bus lengths Max. device Connecting a Scsi ArrayTo connect the Scsi Diamond-VT BitsScsi connections Atto ExpressNAV Accessing the Diamond-VTCommand Line Interface RS-232 portSnmp In-band CLI Over Fibre Channel DetailsInitiator Host Diamond-VT Initiator/Host Diamond-VT Serial Port Access Serial port access To use Telnet Ethernet Access Telnet and Snmp ProtocolsTo connect to the Ethernet port To use SnmpTraps are generated for the following situations Atto ExpressNAV Browser-based Interface Navigating ExpressNAVBrowser compatibility Reset button Parameter name Submit buttonExpressNAV Pages Logical Units Tape VolumesConfiguration PartitionsCLI Interface via ASCII-based Commands SaveConfiguration commandReady Return type/mode Return format/content HostnameSummary of CLI Commands Command Defaults ExampleCLI index Zoneaddhost zone1 General Use Commands Ethernet Commands TelnetTimeout SNMPUpdatesTelnetPassword SNMPTrapsFibre Channel Configuration Commands FcScsiBusyStatus FcPortListFcPortName FcWWNameSerialPortHandshake Serial Port Configuration CommandsSerialPortBaudRate SerialPortEchoMaintenance Services Commands Diagnostic Commands TapeVolumeInfo PowerAudibleAlarmSledFaultLED RAID5ClearDataStatusDrive Management Commands IdeTransferRate DriveWipeLUNState IdeWriteCacheRAIDHaltRebuild RAID5ClearDataRAIDInterleave RAIDManualRebuildRebuildPriority RestoreModePagesTapeVolumeBlockSize TapeWriteProtectZoneDelete ZoneClearAllZoneCreate ZoneRemoveDeviceCLI configure drives RAID Level Configuring the Diamond-VTVirtual Tape Volumes Hot Spare sledsInterleave Enhancing performanceVirtual Tape To set up RAID Level 10 with Hot Spare sleds Optional Hot Spare SledPrinciples of Zoning Planned configuration is a work-in-processZones Device portion defines the LUNsFactors to consider Status and Sense DataType ZoneInfo To remove zones Configuring ZoningTo create a zone To change current zonesErrors Zone definition tables The Zone commandsUpdating Firmware Updating firmware via the RS-232 serial portUpdating firmware via the optional Ethernet card Cd c\diamond\flash Type put ....imaRS-232 Monitoring Port and CLI One tool to Diagnostics, Upgrade and MaintenancePower On Self Test Post Each time Ethernet Monitoring Port and CLI If the optionalPower Supply Monitoring The Diamond-VT System Fault LED and Error Codes If a serious25C 32C 35C 40C Disk Drive Activity and Disk Fault LEDs Each Monitoring, reporting Command Line Interface messages TroubleshootingWindows 2000 special instructions Error Messages Specific situations and suggestionsIf you cannot read or write to the Diamond-VT If a power supply failsIf you can’t access the Diamond-VT CLI via Ethernet Type FirmwareRestart in CLIDefault Resetting DefaultsFactory Default Return to Default settingsCommand Default Rebuilding RAID Level 5 and 10 Configurations To synchronize mirrored drives manually Hardware Maintenance Hardware maintenance Hot Swap Operating Instructions Disk DrivesPower Supplies To replace a blower assemblyBlower Assemblies SAN technology Appendix a GlossaryFibre Channel technology Scsi protocolAppendix Feature Appendix B ATA Disk TechnologyFibre Channel Appendix C LunInfo for a Jbod setup LunInfo PartitionInfo active 59TapeVolumeInfo ZoneInfoViii Simple configuration Appendix D Sample Zoning Command SequencesFirst time configuration after download Symmetric ModelZoneAddPort zone1 ZoneCreate zone2 Asymmetric ModelZoneClearAll ZoneCreate zone1 ZoneAddPort zone2 ZoneCreate zone3Combined Symmetric/Asymmetric Model Floor Mount Dimensions Appendix E SpecificationsRack Mount Dimensions Environmental and physicalEMC specifications Appendix F Product SafetySafety compliances Radio and television interferenceAppendix G Part numbers Description All modelsAppendix H Warranty Manufacturer limited warrantyContact Atto Technology, Inc