6.6 Maintenance Services Commands
Maintenance commands allow updating and maintenance of the
FcScsiBusyStatus
You may set the Diamond to report busy or queue full when it is unable to accept a command.
Default: Busy
Set syntax: set FcScsiBusyStatus [busyqfull]
FirmwareRestart
Causes a warm restart of the Diamond Storage Array
Immediate command: FirmwareRestart
MaxEnclTempAlrm
Sets/displays the maximum enclosure temperature alarm of the Diamond Storage Array in degrees Celsius. Valid entries are between 5 and 52 degrees and above the current minimum enclosure temperature alarm
Default: 47
Set syntax: set MaxEnclTempAlrm
Requires a SaveConfiguration command
Get syntax: get MaxEnclTempAlrm
MinEnclTempAlrm
Sets/displays the minimum enclosure temperature alarm of the Diamond Storage Array in degrees Celsius.Valid entries are between 5 and 47 degrees and below the current maximum enclosure temperature alarm
Default: 5
Set syntax: set MinEnclTempAlrm
Requires a SaveConfiguration command
Get syntax: get MinEnclTempAlrm
ResolveLUNConflicts
Immediate command: ResolveLUNConflicts
RestoreConfiguration
Restores configuration to either the default configuration or the configuration last saved into
Immediate: RestoreConfiguration [DefaultSaved]
SaveConfiguration
If the restart option is selected, the Diamond will cycle its power. The norestart option will save changes without restarting. Please note: certain modifications require a
SaveConfiguration command and a system restart. If required, the return Ready. * will be displayed after the return for the modification. You may make several changes through commands and SaveConfiguration before implementing a restart, but once you have restarted the Diamond, all the command changes created before the restart and saved will be implemented. Restart or no Restart parameter is optional
Immediate: SaveConfiguration <Restart NoRestart>
SpeedWrite
SpeedWrite is a method to improve the performance of FCP WRITE commands to SCSI devices attached to the array.
Default: disabled
Set syntax: set SpeedWrite [enabled disabled] Requires a SaveConfiguration Restart command Get syntax: get SpeedWrite
Temperature
Returns the current internal temperature of this Diamond Storage Array in degrees Celsius. The value is read only.
Get syntax: get Temperature
Zmodem
Use the Zmodem protocol to transfer a file to or from the Diamond Storage Array. The filename is required if the ‘send’ option is specified. Available only through the RS- 232 interface
CAUTION
After a firmware image is downloaded to the Diamond Storage Array, the image is placed into flash memory. During this time (about 90 seconds), DO NOT remove power to the Diamond Storage Array or the flash may become corrupted. Power should not be removed until the READY prompt appears.
Immediate command: Zmodem [Send filenameReceive]
ZoneRetrieve
Retrieves the Active Zone Configuration into the Planned Zone Configuration to allow modifications of the current configuration.
Zone syntax: ZoneRetrieve
38 CLI: maintenance