ATTO Technology VT-Class manual Appendix D Sample Zoning Command Sequences, Simple configuration

Page 90

Appendix D Sample Zoning Command Sequences

First time configuration (after download)

QuickRAID under Zoning “first time” configuration, an all/all/all configuration in the selected QuickRAID configuration. All zone commands except

ZoneCommit affect only the planned configuration. ZoneCommit sets the Planned Configuration into the Active Configuration.

ZoneClearAll

Clears any previously-defined zones

 

 

ZoneCommit

Sets the new zoning configuration.

 

 

Simple configuration

2 hosts. Hosts can use different operating systems. All zone commands except ZoneCommit affect only the

planned configuration. ZoneCommit sets the Planned Configuration into the Active Configuration.

ZoneClearAll

Clears any previously defined zones from the planned

 

configuration.

 

 

ZoneCreate zone_1

Creates a zone named zone_1

 

 

ZoneAddHost zone_1 20:00:00:10:86:00:01:34

Adds host WWPN to zone_1

 

 

ZoneAddDevice zone_1 1 4

Adds LUN 1 and 4 to zone_1

 

 

ZoneAddPort zone_1 0

LUN 1 and LUN 4 will be available through HIC 0 for only the host

 

in zone_1

 

 

ZoneCreate zone_2

Creates a zone named zone_2

 

 

ZoneAddHost zone_2 20:00:00:60:00:00:12:34

Adds host WWPN to zone_2

 

 

ZoneAddDevice zone_2 7

Adds LUN 7 to zone_2

 

 

ZoneAddPort zone_2 1

LUN 7 will be available through HIC 1 for only the host in zone_2

 

 

ZoneState zone_1 enabled

Enables zone_1.

 

 

ZoneState zone_2 enabled

Enables zone_2.

 

 

ZoneCommit

Sets the Planned Zoning Configuration into the Active

 

configuration. No other LUNs will be available to any host.

 

 

Symmetric Model

1 host, 1 switch. All host ports travel through a switch to both Diamond ports. Zoning is not required, since there is no reason to restrict host/HBA/Port access. All

zone commands except ZoneCommit affect only the planned configuration. ZoneCommit sets the Planned Configuration into the Active Configuration.

ZoneClear all

Clears any previously-defined zones from the planned configuration

 

 

ZoneCommit

Copies what is in the Planned Zoning Configuration to the Active Configuration: in this case, clears

 

any previously-defined zones.

 

 

A-ix

ATTO Technology Inc. Diamond Storage Array Installation and Operation Manual

Image 90
Contents Diamond Storage Array VT-Class Page Page Contents Atto ExpressNAV Browser-based Interface ExpressNAV PagesMaintenance Services Commands Fibre Channel Configuration CommandsSerial Port Configuration Commands Diagnostic CommandsDrive Management Commands ECCResetting Defaults Configuring the Diamond-VTDiagnostics, Upgrade and Maintenance Troubleshooting Virtual TapeAppendix F Product Safety Xiii Appendix D Sample Zoning Command SequencesAppendix E Specifications Xii Appendix G Part numbers Xiv Appendix H WarrantyPreface DisclaimerAtto Technology, Inc Page Diamond-VT features Diamond Storage Array-VT Product OverviewFibre Channel model Scsi modelEthernet Diamond-VT Technical OverviewRS-232 400MB/secAdxt Powers ATA to New Levels ATA Interface Engine AIE The interface to eachSet up the Ethernet connection Installation InstructionsPhysical setup Connect to EthernetConnect to Ethernet, on page 5, follow Set up Virtual Tape configurationConfiguration examples RAID Level 10 with Hot Spare sledsDiamond-VT Components Floor modelRack mount model Diamond-VT Physical Setup Floor ModelRack Mount Physical setup Connecting a Fibre Channel Array AutoconfigurationManual configuration Fibre Channel connections Bus speed, MB/sec Bus width Max. bus lengths Max. device Connecting a Scsi ArrayTo connect the Scsi Diamond-VT BitsScsi connections Atto ExpressNAV Accessing the Diamond-VTCommand Line Interface RS-232 portSnmp In-band CLI Over Fibre Channel DetailsInitiator Host Diamond-VT Initiator/Host Diamond-VT Serial Port Access Serial port access To use Telnet Ethernet Access Telnet and Snmp ProtocolsTo connect to the Ethernet port To use SnmpTraps are generated for the following situations Atto ExpressNAV Browser-based Interface Navigating ExpressNAVBrowser compatibility Reset button Parameter name Submit buttonExpressNAV Pages Logical Units Tape VolumesConfiguration PartitionsCLI Interface via ASCII-based Commands SaveConfiguration commandReady Return type/mode Return format/content HostnameSummary of CLI Commands Command Defaults ExampleCLI index Zoneaddhost zone1 General Use Commands Ethernet Commands TelnetTimeout SNMPUpdatesTelnetPassword SNMPTrapsFibre Channel Configuration Commands FcScsiBusyStatus FcPortListFcPortName FcWWNameSerialPortHandshake Serial Port Configuration CommandsSerialPortBaudRate SerialPortEchoMaintenance Services Commands Diagnostic Commands TapeVolumeInfo PowerAudibleAlarmSledFaultLED RAID5ClearDataStatusDrive Management Commands IdeTransferRate DriveWipeLUNState IdeWriteCacheRAIDHaltRebuild RAID5ClearDataRAIDInterleave RAIDManualRebuildRebuildPriority RestoreModePagesTapeVolumeBlockSize TapeWriteProtectZoneDelete ZoneClearAllZoneCreate ZoneRemoveDeviceCLI configure drives RAID Level Configuring the Diamond-VTVirtual Tape Volumes Hot Spare sledsInterleave Enhancing performanceVirtual Tape To set up RAID Level 10 with Hot Spare sleds Optional Hot Spare SledPrinciples of Zoning Planned configuration is a work-in-processZones Device portion defines the LUNsFactors to consider Status and Sense DataType ZoneInfo To remove zones Configuring ZoningTo create a zone To change current zonesErrors Zone definition tables The Zone commandsUpdating Firmware Updating firmware via the RS-232 serial portUpdating firmware via the optional Ethernet card Cd c\diamond\flash Type put ....imaRS-232 Monitoring Port and CLI One tool to Diagnostics, Upgrade and MaintenancePower On Self Test Post Each time Ethernet Monitoring Port and CLI If the optionalPower Supply Monitoring The Diamond-VT System Fault LED and Error Codes If a serious25C 32C 35C 40C Disk Drive Activity and Disk Fault LEDs Each Monitoring, reporting Command Line Interface messages TroubleshootingWindows 2000 special instructions Error Messages Specific situations and suggestionsIf you cannot read or write to the Diamond-VT If a power supply failsIf you can’t access the Diamond-VT CLI via Ethernet Type FirmwareRestart in CLIDefault Resetting DefaultsFactory Default Return to Default settingsCommand Default Rebuilding RAID Level 5 and 10 Configurations To synchronize mirrored drives manually Hardware Maintenance Hardware maintenance Hot Swap Operating Instructions Disk DrivesPower Supplies To replace a blower assemblyBlower Assemblies SAN technology Appendix a GlossaryFibre Channel technology Scsi protocolAppendix Feature Appendix B ATA Disk TechnologyFibre Channel Appendix C LunInfo for a Jbod setup LunInfo PartitionInfo active 59TapeVolumeInfo ZoneInfoViii Simple configuration Appendix D Sample Zoning Command SequencesFirst time configuration after download Symmetric ModelZoneAddPort zone1 ZoneCreate zone2 Asymmetric ModelZoneClearAll ZoneCreate zone1 ZoneAddPort zone2 ZoneCreate zone3Combined Symmetric/Asymmetric Model Floor Mount Dimensions Appendix E SpecificationsRack Mount Dimensions Environmental and physicalEMC specifications Appendix F Product SafetySafety compliances Radio and television interferenceAppendix G Part numbers Description All modelsAppendix H Warranty Manufacturer limited warrantyContact Atto Technology, Inc