ATTO Technology VT-Class manual TapeVolumeInfo, ZoneInfo

Page 88

Volume

Partition

Total % Capacity

Write

ID

LUN VDID ID

Capacity Used

Protection

===============================================

059

- 59

0

3439315MB

0% disabled

Ready.

 

 

 

 

TapeVolumeInfo 059

Volume ID

: 059

LUN

:

VDID

: 59

Partition ID

: 0

Device Kind

: RAID5

Device State

: OFFLINE

Total Capacity

: 3439315MB

% Capacity Used

: 0%

Write Protection

: disabled

Primary Volume ID : G80FQC2E____________5AA0000

Volume Sequence Number : 0

VirtualDriveInfo

TYPE

VDID #Parts

State

Capacity

Serial Number

====== ==== ====== ======= =======

=========

RAID5

59

4

ONLINE 305165MB V80EE4YC5AN

RAID5

60

1

ONLINE 305167MB V80DTCWC5AN

RAID5

61

1

ONLINE 305167MB V80D44LC5AN

RAID5

62

1

ONLINE 293227MB V80ED9GC5AN

VirtualDriveInfo active 59

 

 

TYPE

VDID #Parts State

Capacity

Serial Number

====== ==== ==== ====== =======

==========

RAID5

59

4

ONLINE 305165MB

V80EE4YC5AN

VirtualDriveInfo active 59

 

 

TYPE

VDID #Parts State

Capacity

Serial Number

====== ==== ==== ====== =======

==========

RAID5

59

4

ONLINE 305165MB

V80EE4YC5AN

Verbose return

 

 

 

 

ZoneInfo

ZoneInfo abcd

Zone: abcd disabled

Host: Remaining

IID: none

Port: 0

Device: 123

ZoneInfo 1234

Zone 1234 disabled

Host: 20:00:00:10:86:00:21:12

IID: none

Port: 0 1

Device: 3 4 5 6

ZoneInfo 1

Zone: zone1 enabled

Host: 20:00:00:10:00:00:00

IID: none

Port: 1

Device: 12345

A-vii

ATTO Technology Inc. Diamond Storage Array Installation and Operation Manual

Image 88
Contents Diamond Storage Array VT-Class Page Page Contents Atto ExpressNAV Browser-based Interface ExpressNAV PagesFibre Channel Configuration Commands Serial Port Configuration CommandsMaintenance Services Commands Diagnostic CommandsDrive Management Commands ECCConfiguring the Diamond-VT Diagnostics, Upgrade and Maintenance TroubleshootingResetting Defaults Virtual TapeAppendix D Sample Zoning Command Sequences Appendix E Specifications XiiAppendix F Product Safety Xiii Appendix G Part numbers Xiv Appendix H WarrantyDisclaimer PrefaceAtto Technology, Inc Page Diamond-VT features Diamond Storage Array-VT Product OverviewFibre Channel model Scsi modelDiamond-VT Technical Overview RS-232Ethernet 400MB/secAdxt Powers ATA to New Levels ATA Interface Engine AIE The interface to eachInstallation Instructions Physical setupSet up the Ethernet connection Connect to EthernetSet up Virtual Tape configuration Configuration examplesConnect to Ethernet, on page 5, follow RAID Level 10 with Hot Spare sledsDiamond-VT Components Floor modelRack mount model Floor Model Diamond-VT Physical SetupRack Mount Physical setup Autoconfiguration Connecting a Fibre Channel ArrayManual configuration Fibre Channel connections Connecting a Scsi Array To connect the Scsi Diamond-VTBus speed, MB/sec Bus width Max. bus lengths Max. device BitsScsi connections Accessing the Diamond-VT Command Line InterfaceAtto ExpressNAV RS-232 portSnmp Details In-band CLI Over Fibre ChannelInitiator Host Diamond-VT Initiator/Host Diamond-VT Serial Port Access Serial port access Ethernet Access Telnet and Snmp Protocols To connect to the Ethernet portTo use Telnet To use SnmpTraps are generated for the following situations Navigating ExpressNAV Atto ExpressNAV Browser-based InterfaceBrowser compatibility Reset button Parameter name Submit buttonExpressNAV Pages Tape Volumes ConfigurationLogical Units PartitionsSaveConfiguration command CLI Interface via ASCII-based CommandsReady Return type/mode Return format/content HostnameSummary of CLI Commands Command Defaults ExampleCLI index Zoneaddhost zone1 General Use Commands Ethernet Commands SNMPUpdates TelnetPasswordTelnetTimeout SNMPTrapsFibre Channel Configuration Commands FcPortList FcPortNameFcScsiBusyStatus FcWWNameSerial Port Configuration Commands SerialPortBaudRateSerialPortHandshake SerialPortEchoMaintenance Services Commands Diagnostic Commands PowerAudibleAlarm SledFaultLEDTapeVolumeInfo RAID5ClearDataStatusDrive Management Commands DriveWipe LUNStateIdeTransferRate IdeWriteCacheRAID5ClearData RAIDInterleaveRAIDHaltRebuild RAIDManualRebuildRestoreModePages TapeVolumeBlockSizeRebuildPriority TapeWriteProtectZoneClearAll ZoneCreateZoneDelete ZoneRemoveDeviceCLI configure drives Configuring the Diamond-VT Virtual Tape VolumesRAID Level Hot Spare sledsInterleave Enhancing performanceVirtual Tape To set up RAID Level 10 with Hot Spare sleds Optional Hot Spare SledPlanned configuration is a work-in-process ZonesPrinciples of Zoning Device portion defines the LUNsStatus and Sense Data Factors to considerType ZoneInfo Configuring Zoning To create a zoneTo remove zones To change current zonesErrors Zone definition tables The Zone commandsUpdating firmware via the RS-232 serial port Updating FirmwareUpdating firmware via the optional Ethernet card Cd c\diamond\flash Type put ....imaDiagnostics, Upgrade and Maintenance Power On Self Test Post Each timeRS-232 Monitoring Port and CLI One tool to Ethernet Monitoring Port and CLI If the optionalSystem Fault LED and Error Codes If a serious Power Supply Monitoring The Diamond-VT25C 32C 35C 40C Disk Drive Activity and Disk Fault LEDs Each Monitoring, reporting Troubleshooting Windows 2000 special instructions Error MessagesCommand Line Interface messages Specific situations and suggestionsIf a power supply fails If you can’t access the Diamond-VT CLI via EthernetIf you cannot read or write to the Diamond-VT Type FirmwareRestart in CLIResetting Defaults Factory DefaultDefault Return to Default settingsCommand Default Rebuilding RAID Level 5 and 10 Configurations To synchronize mirrored drives manually Hardware Maintenance Hardware maintenance Hot Swap Operating Instructions Disk DrivesTo replace a blower assembly Power SuppliesBlower Assemblies Appendix a Glossary Fibre Channel technologySAN technology Scsi protocolAppendix Appendix B ATA Disk Technology FeatureFibre Channel Appendix C LunInfo for a Jbod setup LunInfo PartitionInfo active 59TapeVolumeInfo ZoneInfoViii Appendix D Sample Zoning Command Sequences First time configuration after downloadSimple configuration Symmetric ModelAsymmetric Model ZoneClearAll ZoneCreate zone1ZoneAddPort zone1 ZoneCreate zone2 ZoneAddPort zone2 ZoneCreate zone3Combined Symmetric/Asymmetric Model Appendix E Specifications Rack Mount DimensionsFloor Mount Dimensions Environmental and physicalAppendix F Product Safety Safety compliancesEMC specifications Radio and television interferenceAppendix G Part numbers Description All modelsManufacturer limited warranty Appendix H WarrantyContact Atto Technology, Inc