Kramer Electronics PL-150 user manual Connecting the PL-50 Power Controller Monitor

Page 12

Connecting the PL-50 Power Controller - Monitor

6 Connecting the PL-50 Power Controller - Monitor

To connect the PL-50, as illustrated in the example in Figure 4, do the following1:

1.Connect up to five2 outlets (from 1 to 5). For example, connect:

OUT 1 to a DVD player

OUT 2 to an LCD display

OUT 4 to a power amplifier with speakers

OUT 5 to a lighting system

2.Set the DIP-switches (see Table 2).

3.Connect an item (for example, an alarm) via the RELAY and/or DIGITAL CONTROL terminal block connectors (not shown in Figure 4).

4.As an option you can connect a PC and/or controller to the RS-232 port, RS-485 port and/or the ETHERNET connector (see section 6.2.1)

5.Connect the power cord3 (not shown in Figure 4).

Figure 4: Connecting the PL-50

1 Be sure that the power is switched OFF on each device before connecting it to your PL-50. After connecting all the devices to your PL-50, switch on the power of the PL-50, and then switch on the power of each device

2 You do not have to connect all the outlets. In this example OUT 3 is not connected

3 We recommend that you use only the power cord that is supplied with this machine

8

KRAMER: SIMPLE CREATIVE TECHNOLOGY

Image 12
Contents Model Contents Figures Instruction Codes43Tables Introduction Getting StartedP3K Wizard Software Quick StartGetting Started Overview EthernetYour PL-50 Power Controller Monitor Your PL-50 Power Controller MonitorPL-50 Power Controller Monitor Front Panel PL-50 Power Controller Monitor Features Feature FunctionInstalling in a Rack Before Installing in a RackConnecting the PL-50 Power Controller Monitor Connecting the PL-50Connecting the Relays Controlling the PL-50 via the Ethernet PortRight-click Local Area Connection Properties Local Area Connection Properties window appearsConnecting via a Straight-Through Cable Click the Connect button Connect screen appears as follows Upload Main ScreenIf required, make changes and click Save. If not, click Exit Controlling via the Embedded Web Pages Following window appearsRunning the Application Panel Screen Scheduler Screen Features Scheduler ScreenHelp BOX Define the Channel Settings screen Channel Settings Screen FeaturesAlerts Screen Features Define the Alerts screenSetting the Alarms Define the Power Measurement screen Power Measurement Screen FeaturesPower ON/OFF Order Screen This page lets you set the power on and OFF order and delay Configurations Screen Enable Security System Security System EnabledSecurity System Operating Your PL-50 Power Controller Monitor DIP-switch SettingsDIP-switch Definitions Calibrating via the Front Panel ButtonsOperating Your PL-50 Power Controller Monitor Flash Memory Upgrade Upgrading the FirmwareClick the Connect button Connect Window appears see Figure Upload ScreenMachine is now connected Connection Time Out MessageUpload Connected Upload Progress When the update is finished, the restart message appears Restart MessageTechnical Specifications Includes the technical specificationsTechnical Specifications1 of the PL-50 Changing the Device ParametersKramer Protocol Protocol 3000 SyntaxHost message format CR LFCommand Terms CommandCommon Commands Factory NameNAME? NAME? NameResult and Error Codes Security CommandsNetwork Setting Commands These commands are used by network devices running ProtocolNET-DHCP NET-DHCP?NET-GATE NET-GATE?Instruction Codes ALARM-OFF ALARM-ONALARM-ON Result ALARM-ON? ALARM-START-ASSwitch MES-MODELVL SCHED?SWITCH? SWITCH-ORDERSWITCH-ORDER-DELAY SWITCH-ORDER-DELAY?Limited Warranty 2900-000576 REV