Kramer Electronics PL-150 Define the Power Measurement screen, Power Measurement Screen Features

Page 25

Connecting the PL-50 Power Controller - Monitor

6.3.6The Power Measurement Screen

Figure 21 and Table 7 define the Power Measurement screen:

 

Figure 21: The Power Measurement Screen

Table 7: The Power Measurement Screen Features

 

 

Feature

Function

Power Status

Status indicator per channel:

 

Measured – if the standby and active values are available (Channel 4 in this

 

example)

 

Not Measured – if one or both of the values were not measured (for

 

example, Channel 1)

Power Measurement

Click Standby or active to measure the standby and/or Active values for an

 

outlet connected to a channel (once measured, the status changes from

 

“Not Measured” to “Measured”)

 

Click clear to clear the Standby and Active data for that channel1

HELP BOX

This page lets you start the "Standby" and "Active" mode measurement process. You can also clear the current "Standby" and "Active" thresholds.

1 You can also reset the data for all the channels by pressing the reset button located on the rear panel of the machine (see Figure 2 and Figure 3) and plugging the power ON while pressing

21

Image 25
Contents Model Contents Instruction Codes43 FiguresTables Getting Started IntroductionP3K Wizard Software Quick StartGetting Started Ethernet OverviewYour PL-50 Power Controller Monitor Your PL-50 Power Controller MonitorPL-50 Power Controller Monitor Front Panel Feature Function PL-50 Power Controller Monitor FeaturesBefore Installing in a Rack Installing in a RackConnecting the PL-50 Connecting the PL-50 Power Controller MonitorControlling the PL-50 via the Ethernet Port Connecting the RelaysRight-click Local Area Connection Properties Local Area Connection Properties window appearsConnecting via a Straight-Through Cable Upload Main Screen Click the Connect button Connect screen appears as followsIf required, make changes and click Save. If not, click Exit Following window appears Controlling via the Embedded Web PagesRunning the Application Panel Screen Scheduler Screen Scheduler Screen FeaturesHelp BOX Channel Settings Screen Features Define the Channel Settings screenDefine the Alerts screen Alerts Screen FeaturesSetting the Alarms Power Measurement Screen Features Define the Power Measurement screenPower ON/OFF Order Screen This page lets you set the power on and OFF order and delay Configurations Screen Security System Enabled Enable Security SystemSecurity System DIP-switch Settings Operating Your PL-50 Power Controller MonitorDIP-switch Definitions Calibrating via the Front Panel ButtonsOperating Your PL-50 Power Controller Monitor Upgrading the Firmware Flash Memory UpgradeUpload Screen Click the Connect button Connect Window appears see FigureConnection Time Out Message Machine is now connectedUpload Connected Upload Progress Restart Message When the update is finished, the restart message appearsIncludes the technical specifications Technical SpecificationsTechnical Specifications1 of the PL-50 Changing the Device ParametersProtocol 3000 Syntax Kramer ProtocolHost message format CR LFCommand Command TermsCommon Commands Name FactoryNAME? NAME? NameSecurity Commands Result and Error CodesThese commands are used by network devices running Protocol Network Setting CommandsNET-DHCP? NET-DHCPNET-GATE NET-GATE?Instruction Codes ALARM-ON ALARM-OFFALARM-ON Result ALARM-ON? ALARM-START-ASMES-MODE SwitchLVL SCHED?SWITCH-ORDER SWITCH?SWITCH-ORDER-DELAY SWITCH-ORDER-DELAY?Limited Warranty 2900-000576 REV