Firmware and Diagnostic Utility 5-7
Test Host Bus Adapters
Select this option to run
1 = Yes. The default is 0.
Choose 0 (No) if you do not have an external loopback connector.
NOTE: Testing the HBA while it is connected to an arbitrated loop is not recommended.
Modify Test Options
Select Test and specify the number of passes on one or more of these tests: PCI loopback, Internal loopback, External Loopback, or all three.
Choose the number of passes (default is 0x50; 0=infinity), and the action to take upon encountering errors (0 = stop, 1 = repeat, 2 = ignore). 0 is the default.
Restart Host Bus Adapters
Select this option to reset the HBA. When a restart HBA occurs, the HBA will perform POST testing and will reload functional firmware.
Input/Output
Select this option to open or close input and output files. The contents of the Input file are interpreted and executed by the program. The output file contains a log of all messages. Note that nesting of input files is not supported.
Maintenance
Select this option to update firmware or