Compaq mar345 manual Scanner Command Area

Page 12

mar345 Program Manual

1 2

______________________________________________________________________________________

Note: Timing is a crucial issue when operating the scanner. If the computer is very busy doing other computations, the internal clock of the program will work slower. A good check for excessive computer activity is if the X−windows server is not able to repaint the user interac e at a reasonable speed.

3.4 Scanner Command Area

The buttons in the command area can be used to send commands directly to the scanner or to pop up further windows, i.e. the mar345−Scan and mar345−Change Paramete rs windows. The functions of the individual buttons are:

_______________________________________________________________________

ButtonDescription

________________________________________________________________________

Collect

Changes layout of the button choices, i.e. the Collect Menu buttons are

 

displayed.

Scan

Pops up the mar345−Scan window.

Erase

Immediately starts to erase the imaging plate. Erasing is identical to doing

 

a scan, but no data are taken.

Initialize

The scanner will move to its distance reference position (usually at the far end

 

of the translation stage). This distance initialization may have to be done if the

 

scanner looses the information about the distance for some reasons. The re−

 

ference positions are taken from the configuration file. The detector move−

 

ment has to be confirmed.

 

The configuration file will be reread when pressing this button.

Open Shutter Opens (or closes) the local X−ray beam shutter.

________________________________________________________________________

And in the Collect Menu there are:

________________________________________________________________________

Single Set

Pops up the mar345−Change Parameters

window for programming

 

a single data set.

 

Multiple Sets

Pops up the mar345−Change Parameters

window for programming

 

up to 64 data sets.

 

Index Crystal

Pops up the mar345−Change Parameters

window for programming

 

a small number of images to be used for indexing a crystal.

MAD Data

Pops up the mar345−Change Parameters

window for programming

 

a data collection typical for anomalous and/or MAD data.

Cancel

Returns to the original layout.

 

________________________________________________________________________

Image 12
Contents Mar research Mar345 Program Manual Version February 24 All Rights ReservedContents Introduction Computer RequirementsEnvironment Command Line Running mar345Input Files Output FilesBasic Concepts and Rules Mar.logMar.spy Mar.lpStarting Up User Interface Main WindowMenu Bar Menu Bar Windows SubmenuScanner Status Area Scanner Command Area Editing Data Collection Parameters Scan mode Collect modeItemDescription Title DirectoryItemDescription First image no No. of imagesExp. time OscillationsWavelength variable Loading and Saving Data Collection Parameters Moving Distance and Phi Starting Data Collection Stopping Data CollectionShutter Timer Single ScanGetting Help Hardware Status14 X−ray Setup Errors and Warnings Image Display Display WindowOptions Submenu FilesColors Show/Hide statisticsReset colors Do not/Keep color scalesTurn On/Off 3D−plot Next imageImage Area Mar345 Program Manual Work Area Information AreasLoad Buttons Zoom ButtonsWindow Title Colors WindowBlue scales RainbowMin MaxCross−Section Window No. of peaksMessage area Moved using the right mouse button Vertical axisUpper horizontal axis Lower horizontal axisData Collection StrategiesChecking Parameters End of Data CollectionImageroot.SUMMARY Imageroot.htmlTroubleshooting No. DescriptionMessage ReasonTabel from previous 1101 Appendix Configuration File Calibration Files