Compaq mar345 manual Work Area, Information Areas, Load Buttons, Zoom Buttons, Colors

Page 29

mar345 Program Manual

2 9

______________________________________________________________________________________

4.4 Work Area

4.4.1 Load Buttons

By pressing the single left or right arrow one can decrease or increase the current image number and load the previous or next image, respectively. The double arrow will continously increase image numbers and continuously load the next image until the stop button is pressed.

4.4.2 Zoom Buttons

By pressing the full image button, the image will be displayed such that it fits entirely into the window. The other buttons will zoom in or zoom out.

4.4.3 Colors

The upper text field has the same function as the "Max"−field in the mar345−Colors window and the lower text field corresponds to the "Min"−field (see chapter 4.9). Dragging the cente r mouse button in the color area, the color distribution changes. Try it out to see what happens!. This doesn’t work for Rainbow mode (see below) and it doesn’t work on 16/24/32−bit color screens, only with 8−bit colors.

4.5 Information Areas

Upper left corner:

When pressing the center mouse button in the image area, the x,y−coordinate, intensity an d resolution of the pixel under the pointer is displayed.

Lower left corner:

Once an image has been loaded successfully, some information (wavelength, distance, maximum intensity and average intensity) is displayed, unless "Hide statistics" was pressed (see 4.2.2).

Upper right corner:

When pressing the "Integrate" button in the "Options" submenu (see 4.2.2) the following information is displayed: number of pixels in x and y, maximum, minimum and average intensity, sum of pixel intensities, standard deviation of intensities, average background and mean intensity over background (all relative to the pixels displayed in the Image Area). The background is calculated from a histogram of intensities of a box of 50x50 pixels around the center of the zoomed area. Pixel values > 1000 are not included in the histogram. This option works for zoom factors >= 1.0 only.

Image 29
Contents Mar research All Rights Reserved Mar345 Program Manual Version February 24Contents Environment IntroductionComputer Requirements Running mar345 Command LineOutput Files Input FilesMar.log Basic Concepts and RulesMar.spy Mar.lpStarting Up Menu Bar User InterfaceMain Window Windows Submenu Menu BarScanner Status Area Scanner Command Area Editing Data Collection Parameters Collect mode Scan modeItemDescription Title DirectoryNo. of images ItemDescription First image noExp. time OscillationsWavelength variable Loading and Saving Data Collection Parameters Moving Distance and Phi Stopping Data Collection Starting Data CollectionSingle Scan Shutter TimerHardware Status Getting Help14 X−ray Setup Errors and Warnings Display Window Image DisplayFiles Options SubmenuColors Show/Hide statisticsDo not/Keep color scales Reset colorsTurn On/Off 3D−plot Next imageImage Area Mar345 Program Manual Information Areas Work AreaLoad Buttons Zoom ButtonsColors Window Window TitleBlue scales RainbowMax MinMessage area Cross−Section WindowNo. of peaks Vertical axis Moved using the right mouse buttonUpper horizontal axis Lower horizontal axisStrategies Data CollectionEnd of Data Collection Checking ParametersImageroot.SUMMARY Imageroot.htmlNo. Description TroubleshootingMessage ReasonTabel from previous 1101 Appendix Configuration File Calibration Files