Compaq mar345 manual Image Area

Page 27

mar345 Program Manual

2 7

______________________________________________________________________________________

4.3 Image Area

In this area, the image is displayed. With the pointer (3−way mouse button) several addition al functions can be accessed.

________________________________________________________________________

Button Action Result

________________________________________________________________________

Left

Press

Pops up an empty mar345−Cross section window

 

Drag

A red line is drawn from the position of the first mouse press

 

 

to the position of the last mouse press.

 

Release

The (interpolated) intensities of the pixels along the line are

 

 

displayed in the mar345−Cross section window.

________________________________________________________________________

Center

Press

The x,y−coordinate, intensity and resolution of the pixel is

 

 

displayed in the information area in the upper left corner of

the image area.

________________________________________________________________________

The right mouse button functions depend on the current zoom factor. At zoom factors < 1, the behaviour is as follows:

________________________________________________________________________

Button Action Result

________________________________________________________________________

Right

Press

Marks one corner of a zoom area.

 

Drag

A red box is drawn from the position of the first mouse press

 

 

to the position of the last mouse press.

 

Release

The pixels contained in the red box are displayed in the

 

 

"Image Area". The magnification factor depends on the size

 

 

of the box and the size of the window.

________________________________________________________________________

At zoom factors >= 1, the currently displayed magnified part of the image will be recentered at the position where the right mouse button has been pressed. By this method, one can move around in the image by always recentering at new positions.

Image 27
Contents Mar research All Rights Reserved Mar345 Program Manual Version February 24Contents Introduction Computer RequirementsEnvironment Running mar345 Command LineOutput Files Input FilesMar.lp Basic Concepts and RulesMar.log Mar.spyStarting Up User Interface Main WindowMenu Bar Windows Submenu Menu BarScanner Status Area Scanner Command Area Editing Data Collection Parameters Directory Scan modeCollect mode ItemDescription TitleOscillations ItemDescription First image noNo. of images Exp. timeWavelength variable Loading and Saving Data Collection Parameters Moving Distance and Phi Stopping Data Collection Starting Data CollectionSingle Scan Shutter TimerHardware Status Getting Help14 X−ray Setup Errors and Warnings Display Window Image DisplayShow/Hide statistics Options SubmenuFiles ColorsNext image Reset colorsDo not/Keep color scales Turn On/Off 3D−plotImage Area Mar345 Program Manual Zoom Buttons Work AreaInformation Areas Load ButtonsRainbow Window TitleColors Window Blue scalesMax MinCross−Section Window No. of peaksMessage area Lower horizontal axis Moved using the right mouse buttonVertical axis Upper horizontal axisStrategies Data CollectionImageroot.html Checking ParametersEnd of Data Collection Imageroot.SUMMARYReason TroubleshootingNo. Description MessageTabel from previous 1101 Appendix Configuration File Calibration Files