Compaq MTEK6000 user manual Label I.D Description Address, Alarms Alarm Code

Page 47

MTEK6000 SERIES USER'S MANUAL

APPENDIX A: PROCESS CONFIGURATION STANDARD

The MTEK6000 uses Process configuration for database organization and management.

Table A-1: Standard display mode and function keys for MTEK6000 EFC

Label I.D.

Description

Address

F1

1

CV

Corr Volume MCF

051102

F2

2

UV

Uncor Volume MCF 051108

F3

3

PR

PRessure PSG

030302

F4

4

FT

Flow Temp F

020304

 

5

FR

Flow Rate MCH

050302

F5

6

SV

Supply Volts VDC

020309

 

7

CT

Case Temp F

020302

 

8

FL

Flow Constant

050601

 

9

PD

Prev Day vol MCF

050903

 

10

CD

Curr Day vol MCF

050905

 

11

CU

Cubic Unit/p CFP

050802

 

12

PS

Press Scale PSG

020402

Table A-2: Standard

alarms for

MTEK6000 EFC

 

Alarms

Alarm Code

First Time Power

130401

Low Supply Volts

130501

High Flow Rate

130601

Low Flow Rate

130701

High Pressure

140401

Low Pressure

140501

Current Day Flow

140601

Faulty Counter

140701

*High Temperature

150401

*Low Temperature

150501

Lost Pressure

150601

*Lost Temperature

150701

LowVolt Shutdown

160401

Open Door

160501

Software Error

160601

Switch #1 Alarm

160701

Switch #2 Alarm

170401

*MTEK6000 EFCV only

Table A-3: Standard history data stored in the MTEK6000 EFC and EFCP

40 days of daily corrected volume

40 days of daily uncorrected volume

40 days of daily maximum flow rate

40 days of daily minimum flow rate

40 days of daily average pressure

40 days of daily average temperature

40 days of hourly corrected volume

40 days of hourly uncorrected volume

40 days of hourly average pressure

40 days of hourly average temperature

40 days of hourly instantaneous supply voltage (snapshots).

40 days of hourly case temperature (snapshots)

January 2002

A-1

Image 47
Contents MTEK6000 Series Table of Contents Optional Equipment List of Figures January January Hazardous Locations OverviewSecurity Options ONE-YEAR WarrantyCompliance MTEK6000 exterior view MTEK6000 interior view Initial Check OUT UnpackingMounting the Instrument on the Meter Power for the MTEK6000Optional Power Supplies Output Shaft Rotation Setting UP the Index AssemblyCounter Masking Unit and Index RotationWall and Pipe Mounting Pulse Input to the MTEK6000Wall Mounting Transducers in the MTEK6000 Connecting the Pressure TubingTypical Installation for MTEK6000 EFC Pipe Size Insertion Thermowell Length Part Number Installing the Thermal ProbePulse Output Wiring Installing the Pulse Output WiringUncorrected Pulse Output Specifications Volume and Alarm Pulse SpecificationsModem Communications 2400 Baud Connecting the Telephone LineCommunications RS-232C Serial Direct Communications 9600 BaudActivity Indicator MTEK6000 Function RS232 cable connected January References GroundingJanuary Display Mode SLEEP/WAKE-UP ModeViewing and clearing alarms using the magnet Alarm ModeHigh Differential Pressure Alarm EFM Faulty Counter Alarm EFCFirst Time Power Alarm High Flow Rate Alarm EFC & EFMLost Temperature Alarm Low Pressure AlarmLow Supply Volts Alarms Low Temperature AlarmMemory History Logging Open Door Alarm optionalSoftware Error Alarm Editing Parameters Configuration ModeOptional Keypad and Display Analog Sampling Assigning Function KeysAudit Trail Wake-Up on Pulse Event DrivenSpecial Key Combinations Calibrating the Pressure Transducer Calibration ModeZero NEW? Calibrating the Temperature TransducerCalibrating the Differential Pressure Transmitter EFM Only Analog Output AO Option Optional EquipmentAnalog Output Option MTEK6000 Analog Output Specifications Zero x.xxx 04.000 +y.yyy mA Calibration Enclosure MaintenanceChanging the Battery Mtek Manager PcGas Meter Utility PackagePcGas Customer Monitor DC2000 January Label I.D Description Address Alarms Alarm CodeTable A-5 Standard alarms for MTEK6000 EFC w/ Aux Pressure Label Description Address Aux Pressure Table A-11 Standard alarms for MTEK6000 EFC2 w/2 Aux Press Table A-14 Standard alarms for MTEK6000 EFM w/ Aux Press MTEK6000 EPR MTEK6000 ETR MTEK6000 Eptr January NX19 Supercompressibility Report AGA-7 Volume CalculationsJanuary Analog Sampling Rate seconds Alarm Pulse Output Enable/DisableAlarm Pulse Time ms Audit Trail Logging EnableConfiguration Password Base TemperatureCalibrate Mode Time-out Calibration PasswordDate Month, Day, Year Flow Rate Update Interval sCubic Unit/Pulse In or Meter Drive High Temperature Alarm Reset High Flow Rate Alarm SetpointHigh Pressure Alarm Setpoint High Pressure Alarm ResetLow Temperature Alarm Reset Low Pressure Alarm SetpointLow Supply Voltage Alarm Reset Low Supply Voltage Alarm SetpointWake Up On Pulse event driven EFC Uncorrected VolumeTime Hhmmss Hours, Minutes, Seconds Wake Up Interval secondsAccumulations Flow & VolumeTemperature Differential Units of MeasureJanuary SBC Revision a Corrector Board Description Jumper position OPT Revision a Option BoardPulse Input #1 PLI Revision C Phone Line Interface Consumer Information and FCC Requirements Service RequirementWarranty & Repair Service EL0001 Sheet 1 of 2 Class I Division 2 Installation EL0001 Sheet 2 of 2 Class I Division 2 Installation Warranty Information January Appendix G TII Station Protector January Appendix H Hazardous Area Installation Control Drawings October October