Compaq user manual Table A-5 Standard alarms for MTEK6000 EFC w/ Aux Pressure

Page 48

MTEK6000 SERIES USER'S MANUAL

Table A-4: Standard display mode and function keys for MTEK6000 EFC w/ Aux Pressure

Label I.D.

Description

Address

F1

1

CV

Corr Volume MCF

051102

F2

2

UV

Uncor Volume MCF 051108

F3

3

PR

PRessure PSG

030302

F4

4

FT

Flow Temp F

020304

 

5

FR

Flow Rate MCH

050302

F6

6

AP

Aux Pressure PSG

020305

F5

7

SV

Supply Volts VDC

020309

 

8

CT

Case Temp F

020302

 

9

FL

Flow Constant

050601

 

10

PD

Prev Day vol MCF

050903

 

11

CD

Curr Day vol MCF

050905

 

12

CU

Cubic Unit/p CFP

050802

 

13

PS

Press Scale PSG

020402

 

14

AS

Aux p Scale PSG

020404

Table A-6: Standard history data stored in the MTEK6000 EFC w/ Aux Pressure

40 days of daily corrected volume

40 days of daily uncorrected volume

40 days of daily maximum flow rate

40 days of daily minimum flow rate

40 days of daily average pressure

40 days of daily average aux. pressure 1

40 days of hourly average aux. pressure 1

40 days of hourly uncorrected volume

40 days of hourly average pressure

40 days of hourly average temperature

40 days of hourly instantaneous supply voltage (snapshots).

40 days of hourly case temperature (snapshots)

Table A-5: Standard alarms for

MTEK6000 EFC w/ Aux Pressure

Alarms

Alarm Code

First Time Power

160401

Low Supply Volts

160501

High Flow Rate

160601

Low Flow Rate

160701

High Pressure

170401

Low Pressure

170501

Current Day Flow

170601

High Temperature

180401

Low Temperature

180501

Lost Pressure

180601

Lost Temperature

180701

Faulty Counter

170701

LowVolt Shutdown

200401

Open Door

200501

Software Error

200601

High Aux Press

190401

Low Aux Press

190501

Lost Aux Press

190601

A-2

January 2002

Image 48
Contents MTEK6000 Series Table of Contents Optional Equipment List of Figures January January Overview Hazardous LocationsONE-YEAR Warranty ComplianceSecurity Options MTEK6000 exterior view MTEK6000 interior view Unpacking Initial Check OUTPower for the MTEK6000 Optional Power SuppliesMounting the Instrument on the Meter Setting UP the Index Assembly Output Shaft RotationUnit and Index Rotation Counter MaskingPulse Input to the MTEK6000 Wall and Pipe MountingWall Mounting Connecting the Pressure Tubing Transducers in the MTEK6000Typical Installation for MTEK6000 EFC Installing the Thermal Probe Pipe Size Insertion Thermowell Length Part NumberInstalling the Pulse Output Wiring Pulse Output WiringVolume and Alarm Pulse Specifications Uncorrected Pulse Output SpecificationsConnecting the Telephone Line CommunicationsRS-232C Serial Direct Communications 9600 Baud Modem Communications 2400 BaudActivity Indicator MTEK6000 Function RS232 cable connected January Grounding ReferencesJanuary SLEEP/WAKE-UP Mode Display ModeAlarm Mode Viewing and clearing alarms using the magnetFaulty Counter Alarm EFC First Time Power AlarmHigh Flow Rate Alarm EFC & EFM High Differential Pressure Alarm EFMLow Pressure Alarm Low Supply Volts AlarmsLow Temperature Alarm Lost Temperature AlarmOpen Door Alarm optional Software Error AlarmMemory History Logging Configuration Mode Editing ParametersOptional Keypad and Display Assigning Function Keys Audit TrailWake-Up on Pulse Event Driven Analog SamplingSpecial Key Combinations Calibration Mode Calibrating the Pressure TransducerCalibrating the Temperature Transducer Zero NEW?Calibrating the Differential Pressure Transmitter EFM Only Optional Equipment Analog Output AO OptionAnalog Output Option MTEK6000 Analog Output Specifications Zero x.xxx 04.000 +y.yyy mA Enclosure Maintenance Changing the BatteryCalibration PcGas Meter Utility Package PcGas Customer MonitorMtek Manager DC2000 January Alarms Alarm Code Label I.D Description AddressTable A-5 Standard alarms for MTEK6000 EFC w/ Aux Pressure Label Description Address Aux Pressure Table A-11 Standard alarms for MTEK6000 EFC2 w/2 Aux Press Table A-14 Standard alarms for MTEK6000 EFM w/ Aux Press MTEK6000 EPR MTEK6000 ETR MTEK6000 Eptr January AGA-7 Volume Calculations NX19 Supercompressibility ReportJanuary Alarm Pulse Output Enable/Disable Alarm Pulse Time msAudit Trail Logging Enable Analog Sampling Rate secondsBase Temperature Calibrate Mode Time-outCalibration Password Configuration PasswordFlow Rate Update Interval s Cubic Unit/Pulse In or Meter DriveDate Month, Day, Year High Flow Rate Alarm Setpoint High Pressure Alarm SetpointHigh Pressure Alarm Reset High Temperature Alarm ResetLow Pressure Alarm Setpoint Low Supply Voltage Alarm ResetLow Supply Voltage Alarm Setpoint Low Temperature Alarm ResetUncorrected Volume Time Hhmmss Hours, Minutes, SecondsWake Up Interval seconds Wake Up On Pulse event driven EFCFlow & Volume Temperature DifferentialUnits of Measure AccumulationsJanuary SBC Revision a Corrector Board OPT Revision a Option Board Description Jumper positionPulse Input #1 PLI Revision C Phone Line Interface Service Requirement Consumer Information and FCC RequirementsWarranty & Repair Service EL0001 Sheet 1 of 2 Class I Division 2 Installation EL0001 Sheet 2 of 2 Class I Division 2 Installation Warranty Information January Appendix G TII Station Protector January Appendix H Hazardous Area Installation Control Drawings October October