MTEK6000 SERIES USER'S MANUAL

CHAPTER 4: OPTIONAL EQUIPMENT

ANALOG OUTPUT (AO) OPTION

The Analog Output Module (part # 1021- 0001B-001) and connecting cable (part # 1002-0245B-001) provides a two-wire, loop-powered, optically isolated, precision 4-20mA output. This module interfaces with the MTEK6000 series product line to provide a 4-20mA output for flow rate, pressure, or numerous other control and monitoring applications. Up to two modules can be installed in the MTEK6000 in place of the batteries by using the AO module adapter plate, (Metretek stk #1008-0011B- 001).

Power for the digital interface section of the AO is selectable by using the DIPswitches, and can be supplied by Vcc of the MTEK6000 or from the main supply voltage. The AO module interfaces to an MTEK6000 series product via the standard I2C serial interface bus. The MTEK6000 unit requests the desired mA output from the AO module using this bus. An I2C digital I/O chip is used to send the information to the analog output section of the AO board.

The analog output section of the board derives its power from the current loop, and is optically isolated from the digital control interface section. The analog output section receives commands from the digital I/O chip through opto-isolators. Commands are in the form of a serial data stream. The AO module provides 4-20mA output signals with a resolution of 1 part in 65536 (16 bit). The D/A also allows for over-ranging of the output to a minimum of 3.5mA and a maximum of 24mA. The field interface to the D/A is a simple two-wire connection. Reverse polarity protection is provided.

January 2002

4 - 1

Image 39
Contents MTEK6000 Series Table of Contents Optional Equipment List of Figures January January Hazardous Locations OverviewONE-YEAR Warranty ComplianceSecurity Options MTEK6000 exterior view MTEK6000 interior view Initial Check OUT UnpackingPower for the MTEK6000 Optional Power SuppliesMounting the Instrument on the Meter Output Shaft Rotation Setting UP the Index AssemblyCounter Masking Unit and Index RotationWall and Pipe Mounting Pulse Input to the MTEK6000Wall Mounting Transducers in the MTEK6000 Connecting the Pressure TubingTypical Installation for MTEK6000 EFC Pipe Size Insertion Thermowell Length Part Number Installing the Thermal ProbePulse Output Wiring Installing the Pulse Output WiringUncorrected Pulse Output Specifications Volume and Alarm Pulse SpecificationsModem Communications 2400 Baud Connecting the Telephone LineCommunications RS-232C Serial Direct Communications 9600 BaudActivity Indicator MTEK6000 Function RS232 cable connected January References GroundingJanuary Display Mode SLEEP/WAKE-UP ModeViewing and clearing alarms using the magnet Alarm ModeHigh Differential Pressure Alarm EFM Faulty Counter Alarm EFCFirst Time Power Alarm High Flow Rate Alarm EFC & EFMLost Temperature Alarm Low Pressure AlarmLow Supply Volts Alarms Low Temperature AlarmOpen Door Alarm optional Software Error AlarmMemory History Logging Editing Parameters Configuration ModeOptional Keypad and Display Analog Sampling Assigning Function KeysAudit Trail Wake-Up on Pulse Event DrivenSpecial Key Combinations Calibrating the Pressure Transducer Calibration ModeZero NEW? Calibrating the Temperature TransducerCalibrating the Differential Pressure Transmitter EFM Only Analog Output AO Option Optional EquipmentAnalog Output Option MTEK6000 Analog Output Specifications Zero x.xxx 04.000 +y.yyy mA Enclosure Maintenance Changing the BatteryCalibration PcGas Meter Utility Package PcGas Customer MonitorMtek Manager DC2000 January Label I.D Description Address Alarms Alarm CodeTable A-5 Standard alarms for MTEK6000 EFC w/ Aux Pressure Label Description Address Aux Pressure Table A-11 Standard alarms for MTEK6000 EFC2 w/2 Aux Press Table A-14 Standard alarms for MTEK6000 EFM w/ Aux Press MTEK6000 EPR MTEK6000 ETR MTEK6000 Eptr January NX19 Supercompressibility Report AGA-7 Volume CalculationsJanuary Analog Sampling Rate seconds Alarm Pulse Output Enable/DisableAlarm Pulse Time ms Audit Trail Logging EnableConfiguration Password Base TemperatureCalibrate Mode Time-out Calibration PasswordFlow Rate Update Interval s Cubic Unit/Pulse In or Meter DriveDate Month, Day, Year High Temperature Alarm Reset High Flow Rate Alarm SetpointHigh Pressure Alarm Setpoint High Pressure Alarm ResetLow Temperature Alarm Reset Low Pressure Alarm SetpointLow Supply Voltage Alarm Reset Low Supply Voltage Alarm SetpointWake Up On Pulse event driven EFC Uncorrected VolumeTime Hhmmss Hours, Minutes, Seconds Wake Up Interval secondsAccumulations Flow & VolumeTemperature Differential Units of MeasureJanuary SBC Revision a Corrector Board Description Jumper position OPT Revision a Option BoardPulse Input #1 PLI Revision C Phone Line Interface Consumer Information and FCC Requirements Service RequirementWarranty & Repair Service EL0001 Sheet 1 of 2 Class I Division 2 Installation EL0001 Sheet 2 of 2 Class I Division 2 Installation Warranty Information January Appendix G TII Station Protector January Appendix H Hazardous Area Installation Control Drawings October October