Compaq MTEK6000 user manual Label Description Address

Page 49

MTEK6000 SERIES USER'S MANUAL

Table A-7: Standard display mode and function keys for MTEK6000 EFC w/2 Aux Pressure

Label

I.D.

Description

Address

F1

1

CV

Corr Volume MCF

051102

F2

2

UV

Uncor Volume MCF 051108

F3

3

PR

PRessure PSG

030302

F4

4

FT

Flow Temp deg F

020304

F6

5

A1

Aux 1 press PSG

020305

F7

6

A2

Aux 2 press PSG

020306

F5

7

SV

Supply Volts VDC

020309

 

8

FR

Flow Rate MCH

050302

 

9

UF

Uncorr Flow MCH

050306

 

10

CT

Case Temp F

020302

 

11

FC

Flow Constant

050601

 

12

PD

Prev Day vol MCF

050903

 

13

CD

Curr Day vol MCF

050905

 

14

CU

Cubic Unit/p CFP

050802

 

15

PS

Press Scale PSG

020402

 

16

AS

Aux 1p Scale psg

020404

 

17

AS

Aux 2p Scale psg

020405

January 2002

Table A-8: Standard

alarms for

MTEK6000 EFCV w/2 Aux Pressure

Alarms

Alarm Code

First Time Power

190401

Low Supply Volts

190501

High Flow Rate

190601

Low Flow Rate

190701

High Pressure

200401

Low Pressure

200501

Current Day Flow

200601

High Temperature

210401

Low Temperature

210501

Lost Pressure

210601

Lost Temperature

210701

Faulty Counter

200701

LowVolt Shutdown

230401

Open Door

230501

Software Error

230601

High Aux 1 Press

220401

Low Aux 1 Press

220501

Lost Aux 1 Press

220601

High Aux 2 Press

240401

Low Aux 2 Press

240501

Lost Aux 1 Press

240601

Switch #1 Alarm

230701

Switch #2 Alarm

240701

A-3

Image 49
Contents MTEK6000 Series Table of Contents Optional Equipment List of Figures January January Hazardous Locations OverviewCompliance ONE-YEAR WarrantySecurity Options MTEK6000 exterior view MTEK6000 interior view Initial Check OUT UnpackingOptional Power Supplies Power for the MTEK6000Mounting the Instrument on the Meter Output Shaft Rotation Setting UP the Index AssemblyCounter Masking Unit and Index RotationWall and Pipe Mounting Pulse Input to the MTEK6000Wall Mounting Transducers in the MTEK6000 Connecting the Pressure TubingTypical Installation for MTEK6000 EFC Pipe Size Insertion Thermowell Length Part Number Installing the Thermal ProbePulse Output Wiring Installing the Pulse Output WiringUncorrected Pulse Output Specifications Volume and Alarm Pulse SpecificationsCommunications Connecting the Telephone LineRS-232C Serial Direct Communications 9600 Baud Modem Communications 2400 BaudActivity Indicator MTEK6000 Function RS232 cable connected January References GroundingJanuary Display Mode SLEEP/WAKE-UP ModeViewing and clearing alarms using the magnet Alarm ModeFirst Time Power Alarm Faulty Counter Alarm EFCHigh Flow Rate Alarm EFC & EFM High Differential Pressure Alarm EFMLow Supply Volts Alarms Low Pressure AlarmLow Temperature Alarm Lost Temperature AlarmSoftware Error Alarm Open Door Alarm optionalMemory History Logging Editing Parameters Configuration ModeOptional Keypad and Display Audit Trail Assigning Function KeysWake-Up on Pulse Event Driven Analog SamplingSpecial Key Combinations Calibrating the Pressure Transducer Calibration ModeZero NEW? Calibrating the Temperature TransducerCalibrating the Differential Pressure Transmitter EFM Only Analog Output AO Option Optional EquipmentAnalog Output Option MTEK6000 Analog Output Specifications Zero x.xxx 04.000 +y.yyy mA Changing the Battery Enclosure MaintenanceCalibration PcGas Customer Monitor PcGas Meter Utility PackageMtek Manager DC2000 January Label I.D Description Address Alarms Alarm CodeTable A-5 Standard alarms for MTEK6000 EFC w/ Aux Pressure Label Description Address Aux Pressure Table A-11 Standard alarms for MTEK6000 EFC2 w/2 Aux Press Table A-14 Standard alarms for MTEK6000 EFM w/ Aux Press MTEK6000 EPR MTEK6000 ETR MTEK6000 Eptr January NX19 Supercompressibility Report AGA-7 Volume CalculationsJanuary Alarm Pulse Time ms Alarm Pulse Output Enable/DisableAudit Trail Logging Enable Analog Sampling Rate secondsCalibrate Mode Time-out Base TemperatureCalibration Password Configuration PasswordCubic Unit/Pulse In or Meter Drive Flow Rate Update Interval sDate Month, Day, Year High Pressure Alarm Setpoint High Flow Rate Alarm SetpointHigh Pressure Alarm Reset High Temperature Alarm ResetLow Supply Voltage Alarm Reset Low Pressure Alarm SetpointLow Supply Voltage Alarm Setpoint Low Temperature Alarm ResetTime Hhmmss Hours, Minutes, Seconds Uncorrected VolumeWake Up Interval seconds Wake Up On Pulse event driven EFCTemperature Differential Flow & VolumeUnits of Measure AccumulationsJanuary SBC Revision a Corrector Board Description Jumper position OPT Revision a Option BoardPulse Input #1 PLI Revision C Phone Line Interface Consumer Information and FCC Requirements Service RequirementWarranty & Repair Service EL0001 Sheet 1 of 2 Class I Division 2 Installation EL0001 Sheet 2 of 2 Class I Division 2 Installation Warranty Information January Appendix G TII Station Protector January Appendix H Hazardous Area Installation Control Drawings October October