Compaq user manual MTEK6000 ETR

Page 54

MTEK6000 SERIES USER'S MANUAL

Table A-19: Standard display mode and function keys for MTEK6000 ETR

Label I.D.

Description

Address

F4

1

FT

Flow Temp F

020304

 

2

HI

High temp In al

080605

 

3

HO

High temp Out al

080606

 

4

LI

Low temp In al

080705

 

5

LO

Low temp Out al

080706

F5

6

SV

Supply Volts DC

020309

 

7

CT

Case Temp F

020302

F6

8

AO

Analog Output #1

160302

 

9

AO

AOut Hi Scale #1

160402

 

10

AO

AOut Lo Scale #1

160403

F7

11

AO

Analog Output #2

170302

 

12

AO

AOut Hi Scale #2

170402

 

13

AO

AOut Lo Scale #2

170403

 

14

OD

Open Door status

070302

 

15

S1

Status input #1

070401

 

16

S2

Status input #2

070402

Table A-20: Standard

alarms for

MTEK6000 ETR

 

Alarms

Alarm Code

First Time Power

080401

Low Supply Volts

080501

High Temperature

080601

Low Temperature

080701

Lost Temperature

090401

LowVolt Shutdown

090501

Open Door

090601

Software Error

090701

Table A-21: Standard history data stored in the MTEK6000 ETR

40 days of daily average temperature

40 days of daily maximum temperature

40 days of daily minimum temperature

40 days of hourly average temperature

40 days of hourly instantaneous supply voltage (snapshots).

40 days of hourly case temperature (snapshots)

15days of 10-minute temperature (snapshots)

A-8

January 2002

Image 54
Contents MTEK6000 Series Table of Contents Optional Equipment List of Figures January January Overview Hazardous LocationsONE-YEAR Warranty ComplianceSecurity Options MTEK6000 exterior view MTEK6000 interior view Unpacking Initial Check OUTPower for the MTEK6000 Optional Power SuppliesMounting the Instrument on the Meter Setting UP the Index Assembly Output Shaft RotationUnit and Index Rotation Counter MaskingPulse Input to the MTEK6000 Wall and Pipe MountingWall Mounting Connecting the Pressure Tubing Transducers in the MTEK6000Typical Installation for MTEK6000 EFC Installing the Thermal Probe Pipe Size Insertion Thermowell Length Part NumberInstalling the Pulse Output Wiring Pulse Output WiringVolume and Alarm Pulse Specifications Uncorrected Pulse Output SpecificationsRS-232C Serial Direct Communications 9600 Baud Connecting the Telephone LineCommunications Modem Communications 2400 BaudActivity Indicator MTEK6000 Function RS232 cable connected January Grounding ReferencesJanuary SLEEP/WAKE-UP Mode Display ModeAlarm Mode Viewing and clearing alarms using the magnetHigh Flow Rate Alarm EFC & EFM Faulty Counter Alarm EFCFirst Time Power Alarm High Differential Pressure Alarm EFMLow Temperature Alarm Low Pressure AlarmLow Supply Volts Alarms Lost Temperature AlarmOpen Door Alarm optional Software Error AlarmMemory History Logging Configuration Mode Editing ParametersOptional Keypad and Display Wake-Up on Pulse Event Driven Assigning Function KeysAudit Trail Analog SamplingSpecial Key Combinations Calibration Mode Calibrating the Pressure TransducerCalibrating the Temperature Transducer Zero NEW?Calibrating the Differential Pressure Transmitter EFM Only Optional Equipment Analog Output AO OptionAnalog Output Option MTEK6000 Analog Output Specifications Zero x.xxx 04.000 +y.yyy mA Enclosure Maintenance Changing the BatteryCalibration PcGas Meter Utility Package PcGas Customer MonitorMtek Manager DC2000 January Alarms Alarm Code Label I.D Description AddressTable A-5 Standard alarms for MTEK6000 EFC w/ Aux Pressure Label Description Address Aux Pressure Table A-11 Standard alarms for MTEK6000 EFC2 w/2 Aux Press Table A-14 Standard alarms for MTEK6000 EFM w/ Aux Press MTEK6000 EPR MTEK6000 ETR MTEK6000 Eptr January AGA-7 Volume Calculations NX19 Supercompressibility ReportJanuary Audit Trail Logging Enable Alarm Pulse Output Enable/DisableAlarm Pulse Time ms Analog Sampling Rate secondsCalibration Password Base TemperatureCalibrate Mode Time-out Configuration PasswordFlow Rate Update Interval s Cubic Unit/Pulse In or Meter DriveDate Month, Day, Year High Pressure Alarm Reset High Flow Rate Alarm SetpointHigh Pressure Alarm Setpoint High Temperature Alarm ResetLow Supply Voltage Alarm Setpoint Low Pressure Alarm SetpointLow Supply Voltage Alarm Reset Low Temperature Alarm ResetWake Up Interval seconds Uncorrected VolumeTime Hhmmss Hours, Minutes, Seconds Wake Up On Pulse event driven EFCUnits of Measure Flow & VolumeTemperature Differential AccumulationsJanuary SBC Revision a Corrector Board OPT Revision a Option Board Description Jumper positionPulse Input #1 PLI Revision C Phone Line Interface Service Requirement Consumer Information and FCC RequirementsWarranty & Repair Service EL0001 Sheet 1 of 2 Class I Division 2 Installation EL0001 Sheet 2 of 2 Class I Division 2 Installation Warranty Information January Appendix G TII Station Protector January Appendix H Hazardous Area Installation Control Drawings October October