Compaq MTEK6000 Units of Measure, Flow & Volume, Accumulations, Static Pressure, Pipe & Orifice

Page 65

MTEK6000 SERIES USER'S MANUAL

It is disabled if set to 0. In this mode, the EFC should be configured to wake up on the number of pulses entered along with an hourly scheduled wake-up to record history

Units of Measure

data. Therefore, the wake up interval (seconds) parameter should be set to 3600. The Default value is 0.

The MTEK6000 can be configured to calculate volume and flow with English or Metric units. The database ca be setup for the following units of measure:

Flow & Volume

ft3 (cubic feet)

Accumulations

M3 (cubic meters)

Static Pressure

PSI (pounds per square inch)

 

Kpa (Kilopascals)

 

Kg / cm2 (kilograms per square centimeter)

 

Bars

 

MBars (millibars)

 

Atmospheres

 

mmHg (millimeters of mercury)

 

mmH2O (millimeters of water)

 

MH2O (meters of water)

 

inH2O (inches of water)

Temperature*

°F

 

°C

Differential

inH2O (inches of water)

Pressure

mmH2O (mm of water)

Pipe & Orifice

inches

Diameter

centimeters

*The units for temperature are automatically set for °F or °C when the units for volume and flow are chosen. Choosing English units (cubic feet) will set the temperature to F, etc.

January 2002

C - 7

Image 65
Contents MTEK6000 Series Table of Contents Optional Equipment List of Figures January January Hazardous Locations OverviewSecurity Options ONE-YEAR WarrantyCompliance MTEK6000 exterior view MTEK6000 interior view Initial Check OUT UnpackingMounting the Instrument on the Meter Power for the MTEK6000Optional Power Supplies Output Shaft Rotation Setting UP the Index AssemblyCounter Masking Unit and Index RotationWall and Pipe Mounting Pulse Input to the MTEK6000Wall Mounting Transducers in the MTEK6000 Connecting the Pressure TubingTypical Installation for MTEK6000 EFC Pipe Size Insertion Thermowell Length Part Number Installing the Thermal ProbePulse Output Wiring Installing the Pulse Output WiringUncorrected Pulse Output Specifications Volume and Alarm Pulse SpecificationsCommunications Connecting the Telephone LineRS-232C Serial Direct Communications 9600 Baud Modem Communications 2400 BaudActivity Indicator MTEK6000 Function RS232 cable connected January References GroundingJanuary Display Mode SLEEP/WAKE-UP ModeViewing and clearing alarms using the magnet Alarm ModeFirst Time Power Alarm Faulty Counter Alarm EFCHigh Flow Rate Alarm EFC & EFM High Differential Pressure Alarm EFMLow Supply Volts Alarms Low Pressure AlarmLow Temperature Alarm Lost Temperature AlarmMemory History Logging Open Door Alarm optionalSoftware Error Alarm Editing Parameters Configuration ModeOptional Keypad and Display Audit Trail Assigning Function KeysWake-Up on Pulse Event Driven Analog SamplingSpecial Key Combinations Calibrating the Pressure Transducer Calibration ModeZero NEW? Calibrating the Temperature TransducerCalibrating the Differential Pressure Transmitter EFM Only Analog Output AO Option Optional EquipmentAnalog Output Option MTEK6000 Analog Output Specifications Zero x.xxx 04.000 +y.yyy mA Calibration Enclosure MaintenanceChanging the Battery Mtek Manager PcGas Meter Utility PackagePcGas Customer Monitor DC2000 January Label I.D Description Address Alarms Alarm CodeTable A-5 Standard alarms for MTEK6000 EFC w/ Aux Pressure Label Description Address Aux Pressure Table A-11 Standard alarms for MTEK6000 EFC2 w/2 Aux Press Table A-14 Standard alarms for MTEK6000 EFM w/ Aux Press MTEK6000 EPR MTEK6000 ETR MTEK6000 Eptr January NX19 Supercompressibility Report AGA-7 Volume CalculationsJanuary Alarm Pulse Time ms Alarm Pulse Output Enable/DisableAudit Trail Logging Enable Analog Sampling Rate secondsCalibrate Mode Time-out Base TemperatureCalibration Password Configuration PasswordDate Month, Day, Year Flow Rate Update Interval sCubic Unit/Pulse In or Meter Drive High Pressure Alarm Setpoint High Flow Rate Alarm SetpointHigh Pressure Alarm Reset High Temperature Alarm ResetLow Supply Voltage Alarm Reset Low Pressure Alarm SetpointLow Supply Voltage Alarm Setpoint Low Temperature Alarm ResetTime Hhmmss Hours, Minutes, Seconds Uncorrected VolumeWake Up Interval seconds Wake Up On Pulse event driven EFCTemperature Differential Flow & VolumeUnits of Measure AccumulationsJanuary SBC Revision a Corrector Board Description Jumper position OPT Revision a Option BoardPulse Input #1 PLI Revision C Phone Line Interface Consumer Information and FCC Requirements Service RequirementWarranty & Repair Service EL0001 Sheet 1 of 2 Class I Division 2 Installation EL0001 Sheet 2 of 2 Class I Division 2 Installation Warranty Information January Appendix G TII Station Protector January Appendix H Hazardous Area Installation Control Drawings October October