3M™ Digital Projector X30N/X35N
SECURITY menu
Item
Description
If this function is set to ON when the vertical angle of the projector or MIRROR setting at which the projector is turned on is different than the previously recorded, the TRANSITION DETECTOR ON alarm will be displayed and the projector will not display the input signal.
•To display the signal again, set this function OFF.
•After about 5 minutes of displaying the TRANSITION DETECTOR ON alarm, the lamp will turn off.
•Keystone adjustment feature has been prohibited as long as the Transition Detector function is on.
1 Turning on the TRANSITION DETECTOR
ENTER NEW PASSWORD
box (small)
TRANSITION
DETECTOR
Pressing the ENTER button on the remote control or the ► button on the projector will return to the TRANSITION DETECTOR on/off menu.
•Please do not forget your TRANSITION DETECTOR password.
•This function will activate only when the projector is started after turning off the AC power.
•This feature may not function properly if the projector is not in a stable position when ON is selected.
2 Turning off the TRANSITION DETECTOR
PASSWORD box (large). Enter the registered password and the screen will return to the TRANSITION DETECTOR on/off menu.
If an incorrect password is input, the menu will | ENTER PASSWORD box |
close. If necessary, repeat the process from | (large) |
|
3 If you have forgotten your password
Inquiring Code will be displayed inside the box.