Indicator Display on the Control Panel

In addition to the standby mode, operate mode and cool down mode*, this unit also displays other operational states using

different combination of indicators.

Please refer to Page 28 for explanations on warning indication for *1and Page 33 for *2.

[STAND BY] light on

[OPERATE] light on

[STAND BY] blinking

Unit is in standby mode

Unit is in operate mode (during opera-

 

 

tion (projection))

 

 

 

 

 

 

STAND BY

 

 

STAND BY

TEMP

OPERATE

 

 

LAMP

LAMP

TEMP

OPERATE

 

 

Unit is in cool down mode (when cooling lamp)

STAND BY

LAMP TEMP OPERATE

[LAMP] blinking*1

Lamp life has expired

(Lamp usage time has exceeded 2000 hours)

STAND BY

LAMP TEMP OPERATE

[LAMP] light on*1

About time to replace lamp

(Lamp usage time has exceeded 1900 hours)

STAND BY

LAMP TEMP OPERATE

[LAMP] and [STAND BY] blink- ing*2

Lamp does not light up and unit is unable to project

STAND BY

LAMP TEMP OPERATE

[LAMP] and [OPERATE]

[LAMP] and [TEMP] blinking*2

[LAMP] and [OPERATE] blinking

blinking simultaneously*1,*2

Circuits are not functioning properly

alternately*2

Lamp turned off during projection

(Abnormal circuit functioning)

Lamp cover has been removed

Time to replace lamp

(when lamp usage time has reached

2010 hours)

 

 

 

 

 

 

 

STAND BY

 

 

 

 

 

 

 

 

 

 

STAND BY

 

 

STAND BY

LAMP

TEMP

OPERATE

 

 

 

 

 

 

 

LAMP

TEMP

OPERATE

LAMP

TEMP

OPERATE

 

 

 

[TEMP] blinking*2

[TEMP] and [STAND BY]

Internal temperature is abnormally high

blinking*2

 

(Abnormal internal temperature)

Temperature at air inlets is high

 

 

(Abnormal external temperature)

 

STAND BY

 

STAND BY

 

 

 

LAMP

TEMP OPERATE

LAMP

TEMP OPERATE

 

 

*About Cool Down Mode

 

Note

All blinking*2

When inner fan has stopped (fan lock)

STAND BY

LAMP TEMP OPERATE

After projection, the heated lamp will go through a 90- second cool-down process known as the cool down mode. This function is to prevent damage and defor- mation that heat from the heated lamp may cause to the internal components of this unit. It also prevents lamp breakage and shortened lamp life.

The cool down mode is indicated by the blinking [STAND BY] indicator. When in the cool down mode, the [OPERATE] button will be disabled.

After the cool down process is completed, the unit will automatically switch to the standby mode.

When in the cool down mode, do not pull out the plug from the power outlet. Also, do not block the air inlets/ exhaust vents by standing this unit on its end or lay- ing it on its side.

11

Image 11
Contents ILA 1080MF2 About burning-in of the D-ILA device About the installation placeFCC Information U.S.A. only Machine Noise Information Germany onlyPower cord Do not allow any unqualified person to install the unitDo not cut off the main plug from this equipment How To Replace The FuseStandard for gauging replacement time of components Accessories ContentsFront Side/Top Surface/Left Side Controls and FeaturesRear Side/Right Side/Bottom Surface DVI Terminal DVI-D 24 Pin Connector PanelService Terminal Sync OUT Terminal RS-232C Terminal D-sub 9 PinControl Panel Indicator Display on the Control Panel Remote Control Load the batteries Loading Batteries into the Remote ControlPrecautions for Using Batteries Open the back coverAdjusting the Inclination Installing the ProjectorInstallation Environment Precaution for UsageMounting this Unit Projector and Screen InstallationPrecautions for Ceiling-mount Screen Size and Projection Distance  Screen Installation When directing remote control unit toward this unit Effective Range of Remote Control Unit When reflecting off a screen  Control from external device Connecting to Various DevicesConnecting to Devices Right Side of this unitWhen using this unit, remove the lens cap Connecting the Power Cord suppliedAdjusting focus Basic Operation ProceduresTurning on the power Adjusting zoom screen sizePress Hide Turning off the powerPull out the power plug from the power outlet Hiding the image temporarilyMenu Structure Adjustments and Settings Using MenusMenu Operation Buttons Button Function This Unit Remote Control UnitTo confirm Press the Menu buttonPress 5/ ∞ to select a main menu item and Enter Options Menu Menu ConfigurationImage adjust Menu Set up MenuPress the Menu button Press 5/∞ to select Set up, followed by pressingScreen Masking Project image onto the screenPress 5/∞ to select Options, followed by press Ing Enter Picture Shift SettingLight-source Lamp and Lamp Usage Time About Lamp ReplacementReplacing the Lamp Tighten the screws of the lamp unit Close the handle Loosen the screws on the lamp unit and lift up the handlePull out the lamp unit Insert the new lamp unit until it is fullyExit Resetting Lamp TimeInsert plug into the power outlet To ensure the lamp time has been resetCleaning and Replacing the Filter Message Cause Details What to do when these messages are displayed Actions to be taken upon warning indications  About warning indicatorsIndicator Please follow the procedures belowTroubleshooting  RS-232C Terminal Pin No Signal NameTerminal Description Pin ArrangementRS-232C External Control Special parameters External control command tableOperation mode Only Asking command is possible Specifications Side  Dimensions Unit mm TopFront BottomMF2MIman v0.90ß