Before sending the unit to your authorized dealer for repair, check the following points.

Symptom

 

Probable Cause

 

Corrective Action

Reference Page

 

 

 

 

 

 

 

 

Power is not

Is the power cord disconnected?

Insert the power cord (plug) firmly.

19

 

supplied.

 

 

 

 

 

 

 

Is the lamp cover properly shut?

Remove the plug when the [STAND BY]

21, 29

 

 

 

 

 

indicator is on. Close the lamp cover prop-

 

 

 

 

 

 

 

 

erly and insert the plug again.

 

 

 

 

 

 

 

 

 

 

 

 

 

Is the filter cover properly shut?

Remove the plug when the [STAND BY]

21, 31

 

 

 

 

 

indicator is on. Close the filter cover prop-

 

 

 

 

 

 

 

 

erly and insert the plug again.

 

 

 

 

 

 

 

 

 

 

 

 

 

Has the lamp life expired? (Has the lamp

Remove the plug when the [STAND BY]

11, 28-30

 

 

 

usage time reached 2000 hours?)

 

indicator is on. Install a new lamp (lamp unit)

 

 

 

 

 

 

 

 

and insert the plug again. Reset the lamp

 

 

 

 

 

 

 

 

time after installing a new lamp (lamp unit).

 

 

 

Light is not

Is the lens cap removed?

Remove the lens cap.

19

 

emitted or light

Is the lamp near exhaustion?

Check the lamp time on the menu. Prepare

22, 25,

is dim.

 

 

 

a new lamp (lamp unit) or replace as soon

28-30

 

 

 

 

 

as possible when the lamp (lamp unit) is

 

 

 

 

 

 

 

 

near exhaustion.

 

 

 

 

 

 

 

 

 

 

 

 

Unit works

Are the air suction openings (air inlets)

Remove the plug when the [STAND BY]

7, 8, 14

when power is

 

and exhaust vents blocked?

 

indicator is on. Remove any blocking ob-

 

 

 

turned on but

 

 

 

ject and insert the plug again.

 

 

 

stops abruptly

 

 

 

 

 

 

 

Are the filters dirty?

Clean the filters.

31

 

after a few

 

 

 

 

 

 

 

minutes.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Video image

Are devices properly connected?

Connect devices correctly.

18

 

does not

 

 

 

 

 

 

 

Are signals being output from the con-

Set connected devices correctly.

 

 

 

 

 

 

appear

 

nected devices?

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Is the video image temporarily turned off

Press the [HIDE] button to display the video

21

 

 

 

 

when the [HIDE] button is being pressed?

 

image again.

 

 

 

Video image is

Is the focus correctly adjusted?

Adjust accordingly using the focus ring.

20

 

fuzzy.

 

 

 

 

 

 

 

Is the unit placed too near or too far away

Set the unit at a correct distance from the

16

 

 

 

 

from the screen?

 

screen.

 

 

 

 

 

 

 

 

 

 

 

Video images

Has setting been performed for screen

Set the “Mask” value in the “Set up” menu

26

 

are missing.

 

mask?

 

to “OFF”.

 

 

 

 

 

Has setting been performed for picture

Alter the “Picture Shift” value in the “Op-

27

 

 

 

 

shift?

 

tions” menu to ensure that images are not

 

 

 

 

 

 

 

 

missing.

 

 

 

 

 

 

 

 

 

 

 

Remote

Are batteries installed correctly?

Match the polarities (+ or -) correctly when

13

 

control unit

 

 

 

inserting the batteries.

 

 

 

does not work.

 

 

 

 

 

 

 

Are batteries exhausted?

Replace with new batteries.

13

 

 

 

 

 

 

 

 

 

 

 

Is there an obstructive object between the

Remove any obstructive objects.

17

 

 

 

 

remote control unit and remote sensor?

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Is the remote control held too far away

Hold the remote control closer to the sen-

17

 

 

 

 

from the screen?

 

sor when using.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

This unit uses a microcomputer. External noise may cause it to malfunction. If this happens, turn off the power and remove the plug from the power outlet. Insert plug again into the outlet and check operation of the unit. (See Pages 20, 21 on how to turn on/off the power of the unit.)

34

Image 34
Contents ILA 1080MF2 Machine Noise Information Germany only About the installation placeFCC Information U.S.A. only About burning-in of the D-ILA deviceDo not allow any unqualified person to install the unit Power cordHow To Replace The Fuse Do not cut off the main plug from this equipmentStandard for gauging replacement time of components Contents AccessoriesControls and Features Front Side/Top Surface/Left SideRear Side/Right Side/Bottom Surface Sync OUT Terminal RS-232C Terminal D-sub 9 Pin Connector PanelService Terminal DVI Terminal DVI-D 24 PinControl Panel Indicator Display on the Control Panel Remote Control Open the back cover Loading Batteries into the Remote ControlPrecautions for Using Batteries Load the batteriesPrecaution for Usage Installing the ProjectorInstallation Environment Adjusting the InclinationPrecautions for Ceiling-mount Projector and Screen InstallationMounting this Unit  Screen Installation Screen Size and Projection Distance When reflecting off a screen Effective Range of Remote Control Unit When directing remote control unit toward this unit Right Side of this unit Connecting to Various DevicesConnecting to Devices  Control from external deviceConnecting the Power Cord supplied When using this unit, remove the lens capAdjusting zoom screen size Basic Operation ProceduresTurning on the power Adjusting focusHiding the image temporarily Turning off the powerPull out the power plug from the power outlet Press HideAdjustments and Settings Using Menus Menu StructureButton Function This Unit Remote Control Unit Menu Operation ButtonsPress 5/ ∞ to select a main menu item and Enter Press the Menu buttonTo confirm Set up Menu Menu ConfigurationImage adjust Menu Options MenuProject image onto the screen Press 5/∞ to select Set up, followed by pressingScreen Masking Press the Menu buttonPicture Shift Setting Press 5/∞ to select Options, followed by press Ing EnterReplacing the Lamp About Lamp ReplacementLight-source Lamp and Lamp Usage Time Insert the new lamp unit until it is fully Loosen the screws on the lamp unit and lift up the handlePull out the lamp unit Tighten the screws of the lamp unit Close the handleTo ensure the lamp time has been reset Resetting Lamp TimeInsert plug into the power outlet ExitCleaning and Replacing the Filter What to do when these messages are displayed Message Cause DetailsPlease follow the procedures below  About warning indicatorsIndicator  Actions to be taken upon warning indicationsTroubleshooting Pin Arrangement Pin No Signal NameTerminal Description  RS-232C TerminalRS-232C External Control Operation mode Only Asking command is possible External control command tableSpecial parameters Specifications Bottom  Dimensions Unit mm TopFront SideMF2MIman v0.90ß