Sharp AL-1650 To remove it, Cartridge out until the green strap handle can be grasped

Page 36

DRUM CARTRIDGE REPLACEMENT

The useful life of the drum cartridge is approximately 30,000 copies. When the internal counter reaches approximately 29,000 copies, the drum replacement required () indicator will light up indicating that replacement of the drum cartridge will be needed soon. When the indicator begins to blink, replace the drum cartridge by following the procedure given below.

Do not remove the protective cover on the drum portion (black paper) of a new drum cartridge before use. The cover protects the drum against external light.

For best copying results, be sure to use only SHARP Genuine Supplies which are designed, engineered and tested to maximize the life and performance of SHARP copiers. Look for the Genuine Supplies label on the drum package.

STATUS INDICATORS Drum cartridge replacement

GENUINE SUPPLIES

Open the bypass tray. Lift slightly on the side cover and

1 slide the cover out until it stops.

Push gently the right side of the front cover to open the

2 cover.

TD cartridge lock

Lift the TD cartridge lock release lever and pull the

3 cartridge out until the green strap handle can be grasped

release lever

 

by the right hand. Lift the cartridge by the handle while

 

supporting it with the left hand at the green label position

 

to remove it.

4 Grasp the handle of the drum cartridge and gently pull the cartridge out.

Dispose of the old drum cartridge in accordance with local regulations.

34

Image 36
Contents AL-1650 For Your Protection Contents Safety Precautions Main Features Part Names and Functions Part Names and Functions AUTO/MANUAL/PHOTO / / key and indicators p Original Size Enter key and indicators pPaper Size indicators Alarm indicatorsDual page Copy key and indicator p Light and dark keys and indicatorsAuto Image key and indicator p @0 Preset Ratio selector keys and indicators pCopier Installation Do not install your copier in areas that areGetting Started Checking Packed Components and Accessories UnpackingInstall the TD cartridge SET-UPGently lift and pull out the paper tray until it stops Turn the power switch on Load copy paper SET-UPFront of the paper tray Store the pressure plate lock which has been removedLoading Copy Paper Push the paper tray firmly back into the copierLoading Copy Paper Press the Start key and then the Paper Size 11ENTER key Using the SPF Turn the power switch onAdjust the copy density Normal CopyingSet the number of copies using the two copy quantity Keys Stream feeding modeNormal Copying Press the Start keyUsing the original table Normal Copying REDUCTION/ENLARGEMENT/ZOOM AutomaticPress the Auto Image Key Enter the number of copies Press the Start keyREDUCTION/ENLARGEMENT/ZOOM ManualBypass Feed special paper Unfold the bypass trayBypass Feed special paper Press the Tray Select key to select the bypassTWO-SIDED Copying XY Zoom Press the XY-ZOOM keyPress the copy ratio display Key XY Zoom Set the number of copies and press the Start keyReverse Press the B/W Reverse key Check the copy paper sizeDual page Copy Press the Dual page Copy keyInterrupting a Copy RUN Press the Interrupt keyStart key to resume copying Replace the original for the interrupted job and pressAutomatic Exposure Adjustment Toner Save Mode Press the AUTO/MANUAL/PHOTO Key To select the Manual ModeTo enter the toner save mode, press the light key TD Cartridge Replacement Genuine SuppliesTD Cartridge Replacement To remove it Cartridge out until the green strap handle can be graspedBy the right hand. Lift the cartridge by the handle while Drum Cartridge Replacement Gently install the TD cartridge. To install the TD cartridgeMisfeed Removal Misfeed in the SPFFirst confirm the misfeed location Right feeding roller cover and remove the misfedMisfeed Removal Misfeed in the bypass trayMisfeed in the copier Gently pull the misfed paper outFusing unit is hot. Take care in removing paper Removing itPush gently the right side of the front cover to open Cover Open the paper guide by pressing down the projection On either side of the guide and remove the misfed paperMisfeed in the upper paper tray Misfeed in the lower paper trayClose the side cover by pressing the handle on the cover Remove the misfed paper Setting the user programs Enter a program number using the left copy quantity KeyUser Programs List of user programsSelect the desired parameter using the right copy quantity User ProgramsPower Save Modes Preheat modeAuto power shut-off mode Power Save Modes Setting the power save modesCopying from the preheat mode User Maintenance Original table and document feeder coverBypass tray paper feed roller Transfer chargerUser Maintenance Charger cleaner out by holding the tabGently lift and pull out the upper paper tray and take Problem Solution Copier TROUBLE?Self-diagnostic function Copier TROUBLE?Example Supplies Types and sizes of copy paperSupply part numbers Supply listSupplies Genuine supplies statementProper storage Store copy paper in the wrapper and lying flatTurn the power switch off and disconnect the power Cord Moving InstructionsPush the paper tray back into the copier Specifications CopierSpecifications Single Pass FeederIndex Index Material Safety Data Sheet Ignition Temperature Special Fire Fighting ProcedureFlash Point Method Used Flammable LimitsIngredients CAS No Proportion Other LimitsHealth Hazards None required under normal use Memo Memo Page Sharp Corporation