Sharp AL-1650 Misfeed Removal, Misfeed in the SPF, First confirm the misfeed location

Page 38

MISFEED REMOVAL

The copier will stop when a misfeed occurs. The misfeed ( ) indicator will blink and blinking red misfeed location indicators will indicate the approximate misfeed location.

If paper is accidentally torn during removal, be sure to remove all pieces. Be careful not to damage the photoconductive drum.

First confirm the misfeed location.

(P. 36)

(P. 37, 40)

(P. 40)

Misfeed in the SPF

A

STATUS INDICATORS Misfeed removal

C

Location A

Left feeding roller cover

If an original misfeed occurs in the SPF, the copier will

Bstop and the red indicator which indicates an original misfeed will blink.

Open the left feeding roller cover and pull the original

1gently to the left and out from the document feeder tray. Close the left feeding roller cover.

Location B

Right feeding roller cover

If the misfed original cannot be removed in step 1, open

2 the right feeding roller cover and remove the misfed

 

 

original. Close the right feeding roller cover.

36

Image 38
Contents AL-1650 For Your Protection Contents Safety Precautions Main Features Part Names and Functions Part Names and Functions Paper Size indicators AUTO/MANUAL/PHOTO / / key and indicators pOriginal Size Enter key and indicators p Alarm indicatorsAuto Image key and indicator p Dual page Copy key and indicator pLight and dark keys and indicators @0 Preset Ratio selector keys and indicators pCopier Installation Do not install your copier in areas that areGetting Started Checking Packed Components and Accessories UnpackingGently lift and pull out the paper tray until it stops Install the TD cartridgeSET-UP Front of the paper tray Turn the power switch on Load copy paperSET-UP Store the pressure plate lock which has been removedLoading Copy Paper Push the paper tray firmly back into the copierLoading Copy Paper Press the Start key and then the Paper Size 11ENTER key Adjust the copy density Using the SPFTurn the power switch on Normal CopyingNormal Copying Set the number of copies using the two copy quantity KeysStream feeding mode Press the Start keyUsing the original table Normal Copying Press the Auto Image Key REDUCTION/ENLARGEMENT/ZOOMAutomatic Enter the number of copies Press the Start keyREDUCTION/ENLARGEMENT/ZOOM ManualBypass Feed special paper Unfold the bypass trayBypass Feed special paper Press the Tray Select key to select the bypassTWO-SIDED Copying Press the copy ratio display Key XY ZoomPress the XY-ZOOM key XY Zoom Set the number of copies and press the Start keyReverse Press the B/W Reverse key Check the copy paper sizeDual page Copy Press the Dual page Copy keyStart key to resume copying Interrupting a Copy RUNPress the Interrupt key Replace the original for the interrupted job and pressAutomatic Exposure Adjustment To enter the toner save mode, press the light key Toner Save ModePress the AUTO/MANUAL/PHOTO Key To select the Manual Mode TD Cartridge Replacement Genuine SuppliesTD Cartridge Replacement By the right hand. Lift the cartridge by the handle while To remove itCartridge out until the green strap handle can be grasped Drum Cartridge Replacement Gently install the TD cartridge. To install the TD cartridgeFirst confirm the misfeed location Misfeed RemovalMisfeed in the SPF Right feeding roller cover and remove the misfedMisfeed in the copier Misfeed RemovalMisfeed in the bypass tray Gently pull the misfed paper outPush gently the right side of the front cover to open Cover Fusing unit is hot. Take care in removing paperRemoving it Open the paper guide by pressing down the projection On either side of the guide and remove the misfed paperClose the side cover by pressing the handle on the cover Misfeed in the upper paper trayMisfeed in the lower paper tray Remove the misfed paper User Programs Setting the user programsEnter a program number using the left copy quantity Key List of user programsSelect the desired parameter using the right copy quantity User ProgramsAuto power shut-off mode Power Save ModesPreheat mode Copying from the preheat mode Power Save ModesSetting the power save modes Bypass tray paper feed roller User MaintenanceOriginal table and document feeder cover Transfer chargerGently lift and pull out the upper paper tray and take User MaintenanceCharger cleaner out by holding the tab Problem Solution Copier TROUBLE?Example Self-diagnostic functionCopier TROUBLE? Supply part numbers SuppliesTypes and sizes of copy paper Supply listProper storage SuppliesGenuine supplies statement Store copy paper in the wrapper and lying flatPush the paper tray back into the copier Turn the power switch off and disconnect the power CordMoving Instructions Specifications CopierSpecifications Single Pass FeederIndex Index Material Safety Data Sheet Flash Point Method Used Ignition TemperatureSpecial Fire Fighting Procedure Flammable LimitsHealth Hazards Ingredients CAS No ProportionOther Limits None required under normal use Memo Memo Page Sharp Corporation